Acessibilidade / Reportar erro

Residual stress evaluation in small diameter pipes welded using orbital TIG process

This work aims in evaluate the effect of orbital TIG welding on the joint's residual stress level, the final microstructure and the superficial aspect of the weld filet, observing the welding energy, number of passes and the type of pulsation effects in small diameter pipes. The test specimens were welded with different energy, pulsation and number of passes levels and after that it were submitted to residual stress measurement in a X-Ray diffractometer, samples were extracted from the test specimens and it were submitted to metallographic analysis. The ending of this work is that: residual stress in the pipes outer surface are compressive, residual stress level in pipes goes down with increasing welding energy, it is smaller for pipes welded with pulsation and in this work it were not effectively influenced by number of passes. Metallographic analyses have shown expected microstructures for the employed material.

Residual Stress; Orbital TIG Welding; X-Ray Diffraction


Associação Brasileira de Soldagem Rua Dr Guilherme Bannitz, 126 conj 42, 04532-060 - São Paulo/SP Brasil, Tel.: (55 11) 3045 5040, Fax: (55 11) 3045 8578 - São Paulo - SP - Brazil