Acessibilidade / Reportar erro

Disinfectant-resistant bacteria in Buenos Aires city hospital wastewater

Resistência bacteriana a desinfetantes em efluentes de um hospital em Buenos Aires, Argentina

Abstracts

Large quantities of disinfectants are used in hospitals, externally on human skin or to eliminate microorganisms from inanimate objects. After use, residual quantities of these products reach the wastewater, exposing the bacteria that survive in hospital wastewaters to a wide range of biocides that could act as a selective pressure for the development of resistance. Increasing attention has been directed recently to the resistance of bacteria to disinfectants. The aim of this paper was to determine the disinfectant bacterial resistance pattern of the microflora released to the urban sewer system by hospital effluents. The characterization of the waste water microflora was performed by determination of the CFU of heterotrophic bacteria, fecal indicator bacteria, Pseudomonas sp. and Staphylococcus sp., in a Buenos Aires hospital effluent. The bacterial resistance to the disinfectants more frequently used in the hospital practice, glutaraldehyde, chlorhexidine and povidone-iodine, was then evaluated. Disinfectant resistant bacterial strains were isolated and typified. Between 10³ and 10(6) chlorexidine resistant bacteria/100 mL were isolated from the samples. Bacteria resistant to other disinfectants ranged between 10³ and 10(4) /100 mL. The bacterial population resistant to desinfectants to was mainly composed by Enterobacteriaceae, Staphylococcus spp, and Bacillus spp, which are highly associated to nosocomial infections. The results obtained show that the hospital effluents are of importance in the bacterial resistance selection process, particularly in the case of disinfectants.

disinfectant; resistance; hospital effluent


Os hospitais utilizam uma grande quantidade de desinfetantes para eliminar microorganismos tanto da pele humana como de superfícies inanimadas. Após sua utilização, esses produtos podem chegar ao esgoto em quantidades residuais. A pressão seletiva exercida pelos antimicrobianos nos efluentes hospitalares propicia a disseminação de linhagens resistentes. Além dos antibióticos, os desinfetantes podem atuar como agentes seletivos de linhagens resistentes aos antimicrobianos. Este trabalho teve como objetivo o estudo do perfil da resistência aos desinfetantes das bactérias lançadas na rede de esgoto pelo efluente hospitalar. Na caracterização microbiológica do efluente do Hospital de Clínicas Buenos Aires, determinou-se a concentração de bactérias heterotróficas, bactérias indicadoras fecais, Pseudomonas sp. e Staphylococcus sp. presentes. A resistência aos desinfetantes empregados no hospital, glutaraldeído, iodo povidona, e clorexidina foi então avaliada. Verificou-se a existência de bactérias resistentes à clorexidina em número variando de 10³ a 10(6) bactérias/100 mL e de bactérias resistentes a outros desinfetantes em uma faixa de variação de 10³ a 10(4) bactérias/100 mL. Bactérias dos gêneros Staphylococcus e Bacillus, e da família Enterobacteriaceae, envolvidas em infecções hospitalares, apresentaram resistência aos desinfetantes testados. Estes resultados indicam que as águas residuárias de hospitais desempenham um papel de grande relevância na disseminação de linhagens bacterianas resistentes aos desinfetantes no meio aquático.

desinfetantes; resistência; efluente hospitalar


MEDICAL MICROBIOLOGY

Disinfectant-resistant bacteria in Buenos Aires city hospital wastewater

Resistência bacteriana a desinfetantes em efluentes de um hospital em Buenos Aires, Argentina

L. NuñezI; J. MorettonI* * Corresponding Author. Mailing address: Cátedra de Higiene y Sanidad, Junín 956 4to piso, 1113 Ciudad de Buenos Aires Argentina. E-mail: lidian@ffyb.uba.ar

ICátedra de Higiene y Sanidad, Facultad de Farmacia y Bioquímica, Universidad de Buenos Aires

ABSTRACT

Large quantities of disinfectants are used in hospitals, externally on human skin or to eliminate microorganisms from inanimate objects. After use, residual quantities of these products reach the wastewater, exposing the bacteria that survive in hospital wastewaters to a wide range of biocides that could act as a selective pressure for the development of resistance. Increasing attention has been directed recently to the resistance of bacteria to disinfectants. The aim of this paper was to determine the disinfectant bacterial resistance pattern of the microflora released to the urban sewer system by hospital effluents. The characterization of the waste water microflora was performed by determination of the CFU of heterotrophic bacteria, fecal indicator bacteria, Pseudomonas sp. and Staphylococcus sp., in a Buenos Aires hospital effluent. The bacterial resistance to the disinfectants more frequently used in the hospital practice, glutaraldehyde, chlorhexidine and povidone-iodine, was then evaluated. Disinfectant resistant bacterial strains were isolated and typified. Between 103 and 106 chlorexidine resistant bacteria/100 mL were isolated from the samples. Bacteria resistant to other disinfectants ranged between 103 and 104 /100 mL. The bacterial population resistant to desinfectants to was mainly composed by Enterobacteriaceae, Staphylococcus spp, and Bacillus spp, which are highly associated to nosocomial infections. The results obtained show that the hospital effluents are of importance in the bacterial resistance selection process, particularly in the case of disinfectants.

Key-words: disinfectant, resistance, hospital effluent

RESUMO

Os hospitais utilizam uma grande quantidade de desinfetantes para eliminar microorganismos tanto da pele humana como de superfícies inanimadas. Após sua utilização, esses produtos podem chegar ao esgoto em quantidades residuais. A pressão seletiva exercida pelos antimicrobianos nos efluentes hospitalares propicia a disseminação de linhagens resistentes. Além dos antibióticos, os desinfetantes podem atuar como agentes seletivos de linhagens resistentes aos antimicrobianos. Este trabalho teve como objetivo o estudo do perfil da resistência aos desinfetantes das bactérias lançadas na rede de esgoto pelo efluente hospitalar. Na caracterização microbiológica do efluente do Hospital de Clínicas Buenos Aires, determinou-se a concentração de bactérias heterotróficas, bactérias indicadoras fecais, Pseudomonas sp. e Staphylococcus sp. presentes. A resistência aos desinfetantes empregados no hospital, glutaraldeído, iodo povidona, e clorexidina foi então avaliada. Verificou-se a existência de bactérias resistentes à clorexidina em número variando de 10³ a 106 bactérias/100 mL e de bactérias resistentes a outros desinfetantes em uma faixa de variação de 10³ a 104 bactérias/100 mL. Bactérias dos gêneros Staphylococcus e Bacillus, e da família Enterobacteriaceae, envolvidas em infecções hospitalares, apresentaram resistência aos desinfetantes testados. Estes resultados indicam que as águas residuárias de hospitais desempenham um papel de grande relevância na disseminação de linhagens bacterianas resistentes aos desinfetantes no meio aquático.

Palavras-chave: desinfetantes, resistência, efluente hospitalar

INTRODUCTION

A variety of substances such as pharmaceuticals, radionucleides and solvents are used in hospitals for medical diagnostics, disinfection and research. After application many non-metabolized drugs are excreted by the patient and enter into wastewater. The microflora of hospital wastewaters is composed by saprophytic bacteria from the atmosphere, soil, medical devices and water employed in the hospital practice; the pathogens are mainly released with the patient excreta.

Large quantities of disinfectants are used in hospitals for a range of purposes. Usually disinfectant compounds are used externally on human skin to prevent or limit microbial infection or for preoperative skin disinfection. They are also used to eliminate microorganisms from inanimate objects (surfaces, instruments). After use residual quantities of disinfectants reach the wastewater (9,22). The hospital effluents are discharged, usually, in the urban sewer system were they mix with other effluents and finally reach the sewage treatment plant. The last step of this process is the release of purified wastewaters to a river, a lake, or to seawaters. Some of these water bodies are sources of drinking water.

Antimicrobial resistance is usually found in the hospital environment. When the antimicrobial drugs attack disease-causing bacteria, they also affect non-pathogenic bacteria in their course. They exterminate these bacteria and make room for more resistant bacterial growth.

The bacteria that survive in hospital wastewaters may be exposed to a wide range of biocides that could act as a selective pressure for the development of resistance. Acquired resistance to biocides may arise by cellular mutation or by the acquisition of genetic elements in the form of plasmids or transposons (21).

Bacterial resistance to antibiotic is a long- established, widely studied problem (6,8,19). Increasing attention has been directed recently to the responses of bacteria to biocides. Griffiths et al. (5) have observed that Micobacterium chelonae isolated from endoscope washer disinfector may be significantly less sensitive to glutaraldehyde in comparison with the type strain. Studies with glutaraldehyde-resistant M. chelonae strains suggest that the arabinogalactan/arabinomannan component of the cell wall is associated with resistance (13). Bacterial isolates have been cultured from industrial plants where triclosan and parachlorometaxylenol were manufactured (10). The prevalence of bacteria with reduced susceptibility to benzalkonium chloride was detected in the effluent of a municipal sewage treatment plant (7). Disinfectants and antiseptics are extensively used in hospital practice around the world, nevertheless the profile of resistance to biocides in the hospital effluents has been barely studied.

The aim of this paper was to determine the disinfectant bacterial resistance pattern of the microflora released to the urban sewer system by the hospital effluent. In a first stage, the characterization of the waste water microflora was performed by determination of the number of colony forming units, CFU, of heterotrophic bacteria, fecal indicator bacteria, Pseudomonas sp. and Staphylococcus sp., in hospital effluent samples. In the next step, the bacterial resistance to disinfectants was studied. The disinfectants more frequently used locally in the hospital practice, glutaraldehyde, chlorhexidine and povidone-iodine, were selected for this study. The resistant strains were isolated and typified for the study of their disinfectant resistance level.

The San Martin hospital is a public health center that provides hospital care in a broad category of illnesses and injuries. This hospital operates with 400 licensed beds (maximum number of beds that the facility can operate) and approximately 300 set-up beds (number of actual beds that are in operation and available for patient use). The Hospital Laboratory conducts test in the following areas: hematology, chemistry, urinalysis, microbiology, blood bank, pathology, and cytology, for both in-patient and out patient services. The San Martin hospital releases daily approximately 560 cubic meters of effluents to the urban sewer system (17).

In Argentina few characterizations of hospital effluents were carried on. One of the main problems of the Buenos Aires city area is the lack of sewer treatment plant. The wastes of the urban sewage system are released to the Rio de la Plata, at a rate of 1.9 millions of m3/day, with no treatment at all. This river is also the source of water for the plants that provide drinking water to the city.

MATERIALS AND METHODS

Collection of samples

The source of test samples was wastewater obtained from the sewer test chamber, in a representative point located just before the release of the San Martin hospital effluents to the urban sewer system. The sampling was performed during a period of 8 h taking a sample every two hours. The same volume of each partial sample was mixed at the end of the day to obtain the composite sample submitted to biological test. The results reported in this paper correspond to ten representative samples taken monthly during the period October 2003- December 2004.

Microbiological analyses

Total heterotrophic count- Serial 10-fold dilutions of samples were prepared in physiological saline, and 0.1 mL aliquots were streak plated on Tryptic soy agar (TSA). Plates were incubated for 48 h at 28ºC before bacteriological counts were preformed.

Fecal indicator (Total coliform, Escherichia coli and Enterococci)- One mL aliquot of appropriate dilution were pour plated in duplicate on CHROMagar ECC for coliform and Escherichia coli, and Slanetz Bartley agar as a selective media for enterococci. The colony count was carried out after incubation at 35ºC for 48 h.

Pseudomonas sp. and Staphylococcus sp. Tenfold dilution of each sample was plated on Cetrimide agar and Baird Parker agar, used for enumeration of Pseudomonas and staphylococci, respectively.

Antimicrobial susceptibility testing

The iodineresistant subpopulation of effluent was selected from the bacterial population by treating wastewater samples 4 minutes with iodine 0.1% (18).

The effluent samples were tested for their resistance patterns determined by dilution agar methods with chlorhexidine 50 mg/L as breakpoint (20).

To evaluate the percentage of glutaraldehyde-resistant bacteria, the effluent samples were added to glutaraldehyde to reach a final concentration of 2% and treated sixty minutes with the disinfectant.

Bacterial identification and test of sensitivity to the biocides

Bacteria tolerant to each disinfectant were identified by different biochemical test, according to the Manual of Clinical Microbiology (15).

The susceptibility of the isolated strains to each disinfectant was analyzed:

MIC values of chlorhexidine were determined on tryptic soy agar (TSA) plates containing a range of chlorhexidine concentrations (500-250-125-100-50-25 ppm), inoculated with 0.1 mL of bacterial suspension. All plates were incubated for 48 h at 35ºC. The MIC was the lowest concentration that prevented bacterial growth (23).

Iodination was performed on suspension ca 107 CFU/mL. Povidone iodine was added to a final concentration of 1%. Samples were removed at intervals, sodium thiosulphate added (final concentration 0.1%) and bacterial dilutions were plated on Tryptic soy agar (TSA).

For the determination of tolerance level to glutaraldehyde 0.1 mL of the suspension was added to 9.9 mL of glutaraldehyde 2%. Samples were removed at intervals (5-20-60 minutes) and mixed with neutralization medium (5). Bactericide activity was expressed as reduction factors, that is, logarithmic reductions in viable organisms:

Reduction factor = log10 CFU/mL (control) - log 10 CFU/mL (treated)

RESULTS

The CFU detected in the samples from hospital wastewater are shown in Table 1. Bacterial counts ranged between 1 x 102 CFU to 1 x 108 CFU/100mL for coliforms; 1 to 4.8 x 105 CFU/100mL for E. coli and 44 to 1.5 x 106 CFU/100mL for enterococci. The proportion of enteric group varied from 58% to 0.75% of the total bacteria.

Pseudomonas was detected in all but two samples. The count of Pseudomonas varied from 2 to 800 CFU/mL, Ferreira La Rosa et al. (4) detected higher concentration of Pseudomonas in hospital de Clínicas de Porto Alegre wastewater. Staphylococcus sp. ranged from 2 to 300 CFU/mL.

Median value for the chlorhexidine resistant bacterial population was 6.8 x 105 per 100 mL. For other disinfectants, the median values were around 103 per 100 mL. The bacterial population showed high resistance to chlorhexidine, a relatively little resistance to glutaraldehyde and to povidone-iodine (Table 2). The resistant bacterial strains for each biocide were isolated and could be identified to at least the genus level (Tables 3 and 4). The MIC of chlorhexidine for the resistant bacteria showed 2 fold increase compared with the sensitive strains. Only Gram-negative rods showed resistance for chlorhexidine, among them Aeromonas hydrophila was the most frequently isolated (Table 3). Table 4 shows the activity of glutaraldehyde against resistant strains. Sixty minutes exposure was insufficient to achieve a 5 log10 reduction of isolated Staphylococcus. On the other hand the Staphylococcus sp. wildtype strain, obtained from Facultad de Farmacia Culture Collection, was susceptible to glutaraldehyde, i.e a 5 log reduction was achieved following exposure for 1minute to 2% glutaraldehyde. Most of the resistant species to glutaraldehyde and povidone-iodine were identified as Gram-positive bacteria.

DISCUSSION

The counts of heterotrophic bacteria and fecal indicator bacteria in the hospital samples were similar to those found by Ortolan (8) in the Porto Alegre Hospital de Clínicas wastewater, Brazil. Similar results were reported by Leprat (10) in hospital wastewaters in France. Lucena et al. (11) reported the results obtained in the microbiological characterization of municipal sewage plants in Argentina. Considering these results, the San Martín Hospital wastewater showed approximately 10 times lower CUF media than those found in municipal sewage systems. On the other hand, oscillations between maximum and minimum values for faecal indicator bacteria were considerable (Table 1). Emmanuel et al. (2) attributed to the presence of disinfectants and antibiotics the high variation in the fecal coliform populations found in hospital wastewater.

Even when the counts of heterotrophic and fecal indicator bacteria in the San Martin effluent were low, the biological risk of the bacteria actually present in the effluents must be high. This risk is mainly associated with the presence of bacteria resistant to antibiotics and disinfectants. In the San Martin wastewater samples an important group of bacteria, namely Gram negate bacilli, resistant to chlorhexidine, was found.

Chlorhexidine is an extensively used handwashing antiseptic. The MIC increase could be the result of different resistance mechanisms, mainly changes in outer membrane proteins (24) or efflux of the disinfectant from the cell (3). The study by Thomas et al. (25) lends some experimental support to the idea that repeated exposure to a subinhibitory concentration increases chlorhexidine MICs of P. aeruginosa. It is reasonable to assume that in a clinical environment and in the hospital effluents bacteria will be exposed to sub-inhibitory amounts of biocides remaining in the environment. Actually clorhexidine has demonstrated to have a persistent or residual effect after application (24).

Iodine has long been considered an effective antimicrobial agent, especially when used in the form of povidone-iodine. Several instances have been described in which iodophors have been found to be contaminated with Pseudomonas sp (1). Pyle et al. (18) found that the bacterial susceptibility to iodine was regulated by nutrient status. The resistance increased in nutrient restricted environments like the oligotropic aquatic system found in the hospital wastewaters. Other mechanisms, including cell aggregation, adhesion to surfaces, usually observed in sewage biofilms, may also be involved in halogen resistance.

Little information had been found on the mechanisms of glutaraldehyde resistance. In this paper we report the first isolation of cocci and bacilli glutaldehyde resistants in sewage. The processes involved in glutaraldehyde resistance are not well understood at the present. The main studies performed in Mycobacteria demonstrated that resistance to this compound was related with the cell wall structure. The importance of the wall in the resistance of cocci and bacilli will deserve further studies on the mechanisms of resistance.

Disinfectants present in the hospital wastewater may act as selective pressure for the retention of the plasmids that often contain the genes for resistance to numerous antibiotics (14,22,23,26). It is generally agreed that the selection and dissemination of resistant bacteria in nature should be avoided in order to ensure effective treatment against infectious diseases in humans and maintain an ecological balance that favors the predominance of a susceptible bacterial flora in nature. The indiscriminate use of antimicrobial agents may disrupt the microbial balance in favor of resistance bacteria. In particular, wastewater from hospital plants could play a role in the selection of resistance bacteria in sewage (6,16).

ACKNOWLEDGEMENTS

This work was partially supported by a grant B096 from the Secretaría de Ciencia y Técnica Universidad de Buenos Aires. We want to thank Ing. Jorge Argento from the Hospital San Martín for his colaboration.

Submitted: December 14, 2006; Approved: September 20, 2007.

  • 1. Anderson, R.I.; Berkelman, R.I.; Mackel, D.C.; Davis, B.J.; Holland, B.W; Martone, W.J. (1984). Investigations into the survival of Pseudomonas aeruginosa in polyoxamer-iodine. Appl. Environ. Microbiol., 49: 757-762.
  • 2. Emmanuel, E.; Perrodin, Y.; Keck, G.; Blanchard, J.-M.; Vermande, P. (2005). Ecotoxicological risk assessment of hospital wastewater: a proposed framework for raw effluents discharging into urban sever network. J. Haz. Mat., A 117: 1-11.
  • 3. Fang, C.T.; Chen, H.C.; Chuang, Y.P.; Chang, S.C.; Wang, J.T. (2002). Cloning of a cation efflux pump gene associated with chlorhexidine resistance in Klebsiella pneumoniae. Antimicrob. Agents Chemother., 46: 2024-2028.
  • 4. Ferreira La Rosa, A.M.; Moschem Tolfo, A.; Olinto Monteggia, L.; Nascimento de Almeida, M.M.; da Silva Ortolan, M.; Genro Bins, M.J.; de Almeida Bendati; M.M.; Raya Rodriguez, M.T. (2000). Gestão de efluentes de serviVos de saúde em Porto Alegre Anais XXVII Congresso Interamericano de Engenharía Sanitária e Ambiental ABES Associaçâo Brasileira de Engenharía Sanitária e Ambiental, Pôrto Alegre, Brasil.
  • 5. Griffths, P.A.; Babb, J.R.; Bradley, C.R.; Fraise, A.P. (1997). Glutaraldehyde resistant Micobacterium chelonae from endoscope washer disinfectors. J. Appl. Bacteriol, 82: 519-526.
  • 6. Guardabassi, L.; Petersen, A.; Olsen, J.; Dalsgaard, A. (1998). Antibiotic resistance in Acinetobacter spp. isolated from sewers receiving waste effluent from a hospital and a pharmaceutical plant. Appl. Environ. Microbiol., 61: 3499-3502.
  • 7. Hingst, V.; Klippel, K.M.; Sontag, H.G. (1995). Epidemiology of microbial resistance to biocides. Zentralbl. Hyg. Umweltmed., 197: 232-251.
  • 8. Iversen, A.; Kühn, I.; Franklin, A.; Möllby, R. (2002). High prevalence of vancomycin-resistant enterococci in swedish sewage. Appl. Environ. Microbiol., 68: 2838-2842.
  • 9. Kümmerer, K. (2001). Drugs in the environment: emission of drugs, diagnostic aids and disinfectants into wastewater by hospitals in relation to other sources. A review. Chemosphere, 45: 957-969.
  • 10. Lear, J.C.; Maillard, J.Y.; Dettmar, P.W.; Goddard, P.A.; Russell, A.D. (2002). Chloroxylenol-and triclosan-tolerant bacteria from industrial sources. J. Ind. Microbiol. Biotechnol., 29: 238-242.
  • 11. Leprat, P. (1998). Les rejets liquides hospitaliers, quels agents et quelles solutions thecniques? Revue Techniques hospitalieres, 632: 49-52.
  • 12. Lucena, F.; Durán, A.E.; Morón, A.; Calderón, E.; Campos, C.; Gantzer, C.; Skraber, S. (2004). Reduction of bacterial indicators and bacteriophages infecting faecal bacteria in primary and secondary wastewater treatments. J. Appl. Microbiol, 97: 1069-1076.
  • 13. Manzoor, S.E.; Lambert, P.A.; Griffiths, P.A.; Gill, M.J.; Fraise, A.P. (1999). Reduced glutaraldehyde susceptibility in Mycobacterium chelonae associated with altered cell wall polysaccharides. J. Antimicrob. Chemother, 43: 759-765.
  • 14. McBain, A.J.; Richard, A.H.; Gilbert, P. (2002). Possible implications of biocida accumulation in the environment on the prevalence of bacterial antibiotic resistance J. Ind. Microbiol. Biotechnol., 29: 326-330.
  • 15. Murray, P.K.; Baron, E.J.; Pfaller, M.A.; Tenover, F.; Yolken, R.H. (1999). Manual of Clinical Microbiology 7ş ed. ASM press, Washington DC.
  • 16. Ortolan, M.G.S. (1999). Avaliaçao do efluente do Hospital de Clinicas de Porto Alegre: citotoxicidade, genotoxicidade, perfil microbiologico de bactérias mesofílicas e resistencia a antibióticos. Porto Alegre, 115p. (Dissertaçao de Mestrado-Faculdade de Agronomía. UFRGS).
  • 17. Paz, M.; Muzio, H.; Gemini, V.; Magdaleno, A.; Rossi, S.; Korol, S.; Moretton, J. (2004). Aguas residuales de un Centro Hospitalario de Buenos Aires, Argentina: Características químicas, biológicas y toxicológicas. Hig. Sanid. Ambient, 4: 83-88.
  • 18. Pyle, B.H.; Shelley, K.W.; Mcfeters, G.A. (1994). Physiological aspects of disinfection resistance in Pseudomonas cepacia. J. Appl. Bacteriol, 76: 142-148.
  • 19. Reinthaler, F.F.; Posch, J.; Feierl, G.; Hass, D.; Ruckenbauer, G.; Mascher, F.; Marth, E. (2003). Antibiotic resistance of E. coli in sewage and sludge. Water Res, 37: 1685-1690.
  • 20. Russell, A.D.; Hammond, S.A.; Morgan, J.R. (1986). Bacterial resistance to antiseptics and disinfectants. J. Hosp. Inf., 7: 213-225.
  • 21. Russell, A.D.; Path, F.R.C. (2001). Mechanisms of bacterial insusceptibility to biocides. Am. J. Infect. Control., 29: 259-261.
  • 22. Russell, A.D. (2003). Biocide use and antibiotic resistance of laboratory findings to clinical and environmental situations. The Lancet Infect. Dis., 3: 794-803.
  • 23. Suller, M.T.E.; Russel, A.D. (1999). Antibiotic and biocide resistance in methicillin-resistant Staphylococcus aureus and vancomycin- resistant enterococcus. J. Hosp. Inf, 43: 281-291.
  • 24. Tattawasart, U.; Hann, A.C.; Maillard, J.-Y.; Furr, J.R.; Russell, A.D. (2000). Cytological changes in chlorhexidine-resistant isolates of Pseudomonas stuzeri. J. Antimicrob. Chemother., 45: 145-152.
  • 25. Thomas, L.; Maillard, J.Y.; Lambert, R.J.W.; Russell, A.D. (2000). Development of resistance to chlorhexidine diacetate in Pseudomonas aeruginosa and the effect of a `residual' concentration. J. Hosp. Inf., 46: 297-303.
  • 26. White, D.G.; McDermott, P.F. (2001). Biocides, drug resistance and microbial evolution. Curr. Opin. Microbiol., 4: 313-317.
  • *
    Corresponding Author. Mailing address: Cátedra de Higiene y Sanidad, Junín 956 4to piso, 1113 Ciudad de Buenos Aires Argentina. E-mail:
  • Publication Dates

    • Publication in this collection
      28 Jan 2008
    • Date of issue
      Dec 2007

    History

    • Accepted
      20 Sept 2007
    • Received
      14 Dec 2006
    Sociedade Brasileira de Microbiologia USP - ICB III - Dep. de Microbiologia, Sociedade Brasileira de Microbiologia, Av. Prof. Lineu Prestes, 2415, Cidade Universitária, 05508-900 São Paulo, SP - Brasil, Ramal USP 7979, Tel. / Fax: (55 11) 3813-9647 ou 3037-7095 - São Paulo - SP - Brazil
    E-mail: bjm@sbmicrobiologia.org.br