Acessibilidade / Reportar erro
Brazilian Dental Journal, Volume: 33, Número: 5, Publicado: 2022
  • Analysis of the mandibular molars root canals morphology. Study by computed tomography Article

    Mantovani, Verônica de Oliveira; Gabriel, Aline Evangelista de Souza; Silva, Ricardo Gariba; Savioli, Ricardo Novak; Sousa-Neto, Manoel Damião; Cruz-Filho, Antonio M.

    Resumo em Inglês:

    Abstract This study aimed to analyze the root and root canal morphology of mandibular first and second molars using CBCT images. A total of 2,400 mandibular molars exams were selected from 600 patients aged between 18 and 75 years. The number of roots, number of root canals, and root canal configuration according to the Vertucci classification were verified. Overall, 94.92% of mandibular first molars and 90.17% of mandibular second molars had two separate roots. Among the biradicular molars, the first molars showed a greater incidence of type IV canals in the mesial root and type I in the distal root. In the second molars, the most common canal form was type IV in the mesial root and type I in the distal root. In the triradicular molars, the type IV and type I configurations were the most common in the mesial root of the first molar and second molar, respectively. In both triradicular molars, there was a prevalence of type I canal in the distal and DL roots. Statistical analysis was performed at a significance level of 0.05. The number of roots was correlated with gender (Spearman test), and the canal's configuration with gender and bilaterality (Wilcoxon test). The subpopulation studied has a high incidence of bilateral symmetry and mandibular molars with two roots with two distinct mesial canals and one distal canal. The bilateral configuration is possible to estimate the number of canals, especially in images that are difficult to visualize, such as atresic canals.
  • Exposure to lipopolysaccharide and calcium silicate-based materials affects the behavior of dental pulp cells Article

    Pedrosa, Marlus da Silva; Vilela, Handially dos Santos; Rahhal, Juliana Garuba; Bueno, Natália Pieretti; Lima, Fabianne Soares; Nogueira, Fernando Neves; Sipert, Carla Renata

    Resumo em Português:

    Resumo Este estudo avaliou a viabilidade celular, produção de citocinas e potencial de mineralização de células da polpa dentária humana (hDPCs) após exposição a lipopolissacarídeo (LPS) e aplicação de materiais à base de silicato de cálcio (CSBM). A caracterização do CSBM foi realizada por espectroscopia (n = 3). Extratos de Bio-C Repair, Biodentine, Cimmo HD e MTA Repair HP foram preparados e diluídos (1: 1, 1: 4 e 1:16). A cultura de hDPCs foi estabelecida e tratada ou não com 1 µg / mL de LPS de Escherichia coli por 7 dias. O ensaio de MTT foi usado para avaliar a viabilidade celular em 24, 48 e 72 h (n = 6). A atividade da fosfatase alcalina (ALP) foi avaliada no dia 7 (n = 4). Il-10 e TNF-α foram quantificados por ELISA em 24 h (n = 6). Os dados foram analisados ​​por ANOVA e teste de Tukey (α = 0,05). A viabilidade celular das hPDCs ativados por LPS foi maior do que o controle não tratado em 48 e 72 h (p <0,05). Diferenças entre hPDCs não tratados e ativados por LPS foram observados para Biodentine e Cimmo HP (p < 0,05). Os CSBM influenciaram na viabilidade celular (p <0,05). A atividade de ALP foi maior em hDPCs ativadas por LPS (p <0,05). Não foram observadas alterações na concentração de TNF-α entre os grupos (p> 0,05). Os CSBM aumentaram a produção de Il-10 (p < 0,05). Os hDPCs ativados por LPS apresentaram um aumento na viabilidade celular e atividade ALP. Os CSBM apresentaram toxicidade moderada e foram capazes de aumentar a viabilidade celular e o potencial de mineralização de hDPCs não tratados e ativados por LPS. Os CSBM também induziram mecanismos anti-inflamatórios sem comprometer os pró-inflamatórios.

    Resumo em Inglês:

    Abstract This study assessed the cell viability, cytokine production, and mineralization potential of human dental pulp cells (hDPCs) after exposure to lipopolysaccharide (LPS) and application of calcium silicate-based materials (CSBM). Characterization of the CSBM was performed by infrared spectroscopy (n = 3). Extracts of Bio-C Repair, Biodentine, Cimmo HD, and MTA Repair HP were prepared and diluted (1:1, 1:4, and 1:16). Culture of hDPCs was established and treated or not with 1 µg/mL of LPS from Escherichia coli for 7 days. MTT assay was used to assess cell viability at 24, 48, and 72 h (n = 6). Alkaline phosphatase (ALP) activity was assayed on day 7 (n = 4). Il-10 and TNF-α were quantified by ELISA at 24 h (n = 6). Data were analyzed by ANOVA and Tukey’s test (α = 0.05). Cell viability of LPS-activated hPDCs was higher than untreated control in 48 and 72 h (p < 0.05). Differences between non-treated and LPS-activated hPDCs were observed for Biodentine and Cimmo HP (p < 0.05). The CSBM influenced the cell viability (p < 0.05). ALP activity was higher in LPS-activated hDPCs (p < 0.05). No changes in the concentration of TNF-α were observed between groups (p > 0.05). The CSBM increased the Il-10 production (p < 0.05). LPS-activated hDPCs presented increased cell viability and ALP activity. The CSBM showed mild toxicity and was able to enhance the cell viability and mineralization potential of untreated and LPS-activated hDPCs. The CSBM also induced anti-inflammatory mechanisms without compromising pro-inflammatory ones.
  • Physico-chemical properties of calcium silicate-based sealers in powder/liquid and ready-to-use forms Article

    Janini, Ana C P; Pelepenko, Lauter E; Gomes, Brenda P F A; Marciano, Marina A

    Resumo em Português:

    Resumo Os cimentos endodônticos obturadores à base de silicato de cálcio foram desenvolvidos em formas pó/líquido ou pré-misturadas prontas para o uso. Foi realizada a avaliação das propriedades físico-químicas de um protótipo pó/líquido MTApex Sealer (Ultradent) em comparação com um material pronto para uso EndoSequence BC Sealer (Brasseler). O cimento obturador pasta/pasta à base de resina epóxi AH Plus (Dentsply) serviu de controle para as comparações. Os cimentos foram avaliados (n = 6) quanto a: tempo de presa (em ambientes secos e úmidos), escoamento e radiopacidade, seguindo a norma ISO-6876/2012; como também o pH. A superfície do material e a caracterização química foram realizadas utilizando a microscopia eletrônica de varredura (MEV) e espectrometria dispersiva de energia (EDS). ANOVA, Shapiro-Wilk, Levene e análise post-hoc com correção de Bonferroni foram realizadas com nível de significância de 5%. O MTApex Sealer exibiu um escoamento mais alto e o EndoSequence BC Sealer teve um tempo de presa significativamente mais longo em ambiente seco em comparação com o ambiente úmido; entretanto, para MTApex Sealer e AH Plus, nenhuma mudança significativa ocorreu quando umidade adicional foi fornecida. Todos os materiais excederam 7 mm de Al de radiopacidade e mostraram uma alcalinidade decrescente ao longo dos 21 dias de análise. A avaliação MEV/EDS resultou em picos de cálcio, silício e respectivo radiopacificador. O protótipo de pó/líquido MTApex Sealer teve o maior escoamento e tempo de presa semelhante em ambientes secos e úmidos; ao contrário, o EndoSequence BC Sealer foi influenciado de maneira crucial pela umidade externa. Isso sugere que a configuração dos materiais em pó/líquido parece ser mais previsível.

    Resumo em Inglês:

    Abstract Calcium silicate-based root canal sealers have been developed in powder/liquid or premixed ready-to-use forms. The evaluation of the physico-chemical properties of a prototype powder/liquid MTApex Sealer (Ultradent) in comparison to a ready-to-use material EndoSequence BC Sealer (Brasseler) was performed. The paste/paste epoxy resin-based AH Plus (Dentsply) served as control for comparisons. The sealers were evaluated (n = 6) regarding setting time (in dry and moist environments), flow and radiopacity, following the ISO-6876/2012 standard. Also, the pH was assessed. Material’s surface and chemical characterization was evaluated using scanning-electron-microscopy (SEM) and energy-dispersive-spectrometry (EDS). Mixed ANOVA, Shapiro-Wilk, Levene, and post-hoc analysis with Bonferroni correction were performed at a significance level of 5%. MTApex Sealer exhibited the highest flow and EndoSequence BC Sealer had a significantly longer setting time in dry compared to the moist environment; however, for MTApex Sealer and AH Plus no significant changes occurred when additional moisture was provided. All materials exceeded 7 mm Al of radiopacity and showed a decreasing alkalinity over the 21 day-analysis. SEM/EDS evaluation resulted in peaks of calcium, silicon, and the respective radiopacifier. The prototype powder/liquid MTApex Sealer had the highest flow and similar setting time in both dry and moist environments; opposingly, EndoSequence BC Sealer was crucially influenced by external moisture. This suggests that the powder/liquid materials’ setting seems to be more predictable.
  • Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters Article

    Henriques, Dilma Helena Neves; Alves, Ana Maria Hecke; Kuntze, Morgane Marion; Garcia, Lucas da Fonseca Roberti; Bortoluzzi, Eduardo Antunes; Teixeira, Cleonice da Silveira

    Resumo em Português:

    Resumo Este estudo avaliou a influência de diferentes espessuras de esmalte e dentina na medição dos níveis de saturação de oxigênio (SpO2) em alta (HP) e baixa (LP) perfusão sanguínea, comparando os valores obtidos em dois oxímetros de pulso (OPs) diferentes, BCI e Sense 10. Trinta dentes recém-extraídos de humanos tiveram suas coroas interpostas entre os OPs e um simulador óptico, que simulava a SpO2 e os batimentos cardíacos por minuto (bpm) nos modos de HP (100% SpO2 / 75 bpm) e LP (86% SpO2 / 75 bpm). Após, as superfícies palatinas / linguais dos dentes foram desgastadas com brocas de diamantadas. A leitura da SpO2 foi realizada novamente usando os dois OPs alternadamente através da face vestibular de cada coroa dental. Os dados foram analisados ​​pelos testes Wilcoxon, Mann-Whitney e Kendall Tau-b (α = 5%). Os resultados mostraram diferença significativa nos modos HP e LP nas leituras de SpO2 através das diferentes espessuras dentárias com o uso do BCI, e no modo LP com o uso do Sense 10, que teve correlação linear significativa (p <0,0001) e menores valores de leitura de SpO2 em relação ao aumento da espessura dentária. Independentemente da espessura do dente, o Sense 10 apresentou valores de leitura significativamente maiores (p <0,0001) do que o BCI em ambos os modos de perfusão. A interposição de diferentes espessuras de esmalte e dentina influenciaram a mensuração da SpO2 pelos OPs, especialmente no modo de baixa perfusão. Os POs foram mais precisos na mensuração da SpO2 quando os níveis simulados de perfusão foram maiores.

    Resumo em Inglês:

    Abstract This study aimed to evaluate the influence of different dental tissue thickness on the measurement of oxygen saturation (SpO2) levels in high (HP) and low (LP) blood perfusion by comparing the values obtained from two different pulse oximeters (POs) - BCI and Sense 10. Thirty freshly extracted human teeth had their crowns interposed between the POs and an optical simulator, which emulated the SpO2 and heart beats per minute (bpm) at HP (100% SpO2/75 bpm) and LP (86% SpO2/75 bpm) modes. Afterwards, the palatine/lingual surfaces of the dental crowns were worn with diamond drills. The reading of SpO2 was performed again using the POs alternately through the buccal surface of each dental crown. Data were analyzed by the Wilcoxon, Mann-Whitney and Kendall Tau-b tests (α=5%). The results showed significant difference at the HP and LP modes in the SpO2 readouts through the different dental thicknesses with the use of BCI, and at the LP mode with the use of Sense 10, which had a significant linear correlation (p<0.0001) and lower SpO2 readout values in relation to the increase of the dental thickness. Irrespective of tooth thickness, Sense 10 had significantly higher readout values (p<0.0001) than BCI at both perfusion modes. The interposition of different thicknesses of enamel and dentin influenced the POs measurement of SpO2, specially at the low perfusion mode. The POs were more accurate in SpO2 measurement when simulated perfusion levels were higher.
  • Leukotriene B4 Loaded in Microspheres Inhibits Osteoclast Differentiation and Activation Article

    Lorencetti-Silva, Francine; Arnez, Maya Fernanda Manfrin; Thomé, João Pedro de Queiroz; Carvalho, Marcio Santos de; Carvalho, Fabrício Kitazono de; Queiroz, Alexandra Mussolino de; Faccioli, Lúcia Helena; Paula-Silva, Francisco Wanderley Garcia

    Resumo em Português:

    Resumo O objetivo deste trabalho foi Investigar a formação de osteoclastos in vivo e se o leucotrieno B4 (LTB4) incorporado em microesferas (MS) poderia ser usado como estratégia terapêutica para promover uma entrega sustentada do mediador e prevenir a diferenciação dos osteoclastos. Métodos: In vivo, a periodontite apical foi induzida em camundongos para investigar a diferenciação e sinalização de osteoclastos na ausência de 5-lipoxigenase (5-LO). In vitro, LTB4-MS foi preparado usando um processo de evaporação e extração de solvente de emulsão de óleo em água. A caracterização e a eficiência do encapsulamento do LTB4 foram investigadas. Macrófagos J774A.1 foram cultivados na presença de fator estimulador de colônia de monócitos (M-CSF) e ligante para o receptor ativador do fator nuclear kappa B (RANKL) e, então, estimulados com LTB4-MS. Citotoxicidade, captação in vitro de MS-LTB4, formação de osteoclastos e expressão gênica foram avaliadas. Resultados: A via 5-LO regula negativamente a formação de osteoclastos in vivo durante o desenvolvimento da periodontite apical. In vitro, LTB4-MS foram fagocitadas pelos macrófagos e não foram citotóxicos para as células. LTB4-MS inibiu a formação de osteoclastos e a síntese dos genes pró-osteoclastogênicos Acp5, Mmp9, Calcr e Ctsk. Conclusões: LTB4-MS inibiu a diferenciação de macrófagos em um fenótipo osteoclástico e a ativação celular sob estímulo de M-CSF e RANKL.

    Resumo em Inglês:

    Abstract To investigate osteoclast formation in vivo and if leukotriene B4 (LTB4) loaded in microspheres (MS) could be used as a therapeutical strategy to promote a sustained delivery of the mediator and prevent osteoclast differentiation. Methods: In vivo, apical periodontitis was induced in mice to investigate osteoclast differentiation and signaling in absence of 5-lipoxygenase (5-LO). In vitro, LTB4-MS were prepared using an oil-in-water emulsion solvent extraction-evaporation process. Characterization and efficiency of LTB4 encapsulation were investigated. J774A.1 macrophages were cultured in the presence of monocyte colony-stimulating factor (M-CSF) and ligand for receptor activator of nuclear factor kappa B (RANKL) and then stimulated with LTB4-MS. Cytotoxicity, in vitro MS-LTB4 uptake, osteoclast formation and gene expression were measured. Results: We found that 5-LO negatively regulates osteoclastic formation in vivo during apical periodontitis development. In vitro, LTB4-MS were up-taken by macrophages and were not cytotoxic to the cells. LTB4-MS inhibited osteoclast formation and the synthesis of osteoclastogenic genes Acp5, Mmp9, Calcr and Ctsk. LTB4-MS inhibited differentiation of macrophages into an osteoclastic phenotype and cell activation under M-CSF and RANKL stimulus.
  • Profile of brazilian research productivity grant holders with a background in pediatric dentistry Article

    Lima, Larissa Chaves Morais de; Bernardino, Veruska Medeiros Martins; Prata, Isolda Mirelle de Lima Ferreira; Lopes, Roanny Torres; Silva, Samara Ellen da; Sousa, Myrelle Leal Campos; Perazzo, Matheus França; Paiva, Saul Martins; Graville-Garcia, Ana Flavia

    Resumo em Português:

    Resumo Este estudo traça o perfil dos pesquisadores bolsistas de produtividade do Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) da área de odontopediatria. Pesquisa transversal com dados coletados na base de currículos acadêmicos brasileiros. Os critérios de elegibilidade abrangeram os pesquisadores bolsistas de produtividade de 2018 a 2020. Foram identificados 215 pesquisadores bolsistas de produtividade na área de odontologia, dos quais 33 com pós-graduação (especialização, mestrado ou doutorado) em odontopediatria. O período de produção científica e trabalho de orientação concluído de iniciação científica, mestrado, doutorado e pós-doutorado foi de 2010 a 2020. Foi realizada análise descritiva e o teste de Kruskall-Wallis foi utilizado para verificar associações (nível de significância de 5%) entre nível da bolsa de produtividade (2, 1D, 1C, 1B ou 1A) e ano de obtenção do grau de doutor. O programa VOSviewer (versão 1.6.17) foi utilizado para identificar colaborações interinstitucionais. A amostra foi composta por pesquisadores de Nível 2 (66,7%), mulheres (66,7%), pesquisadores vinculados a instituições da região sudeste do Brasil (81,8%), com doutorado concluído antes de 2002 (51,5%), começaram a atuar como professor em instituição de ensino superior anterior a 2007 (78,8%) e o título de professor titular (45,5%). Não foi encontrada associação significativa entre nível de bolsa de produtividade e ano de conclusão do doutorado (p = 0,10). A mediana (intervalo interquartil) de artigos científicos foi de 119 (37-312). A prevalência de citações (57,52%) e artigos do JCR (62,76%) foi maior entre as pesquisadoras. Em conclusão, os pesquisadores bolsistas de produtividade em Odontopediatria do CNPq são representados essencialmente por mulheres da região sudeste do país. No entanto, os homens apresentaram produtividade proporcionalmente maior.

    Resumo em Inglês:

    Abstract This study outlines the profile of research productivity grant holders of the Conselho Nacional de Desenvolvimento Científico e Tecnológico [CNPq (National Council for Scientific and Technological Development)] in the field of pediatric dentistry. A cross-sectional study with data collected from the Brazilian academic curriculum vitae database. The eligibility criterion was being a research productivity grant holder in pediatric dentistry from 2018 to 2020. In the period of interest, 215 individuals were research productivity grant holders in the field of dentistry, 33 of whom had graduate degrees (specialization, master's or doctorate) in pediatric dentistry. The period of scientific production and work concluded of advising of scientific initiation, master, doctoral and post-doctoral degrees was 2010 to 2020. Descriptive analysis was performed and the Kruskal-Wallis test was used to analyze associations (5% significance level) between productivity grant level (2, 1D, 1C, 1B or 1A) and year of obtainment of the doctoral degree. The VOSviewer (version 1.6.17) was used to present graphically the interinstitutional collaborations. The sample was composed of Level 2 researchers (66.7%), women (66.7%), researchers linked to institutions in the southeastern region of Brazil (81.8%), with a doctoral degree concluded prior to 2002 (51.5%), began working as a professor at a higher education institution prior to 2007 (78.8%) and the title of full professor (45.5%). No significant association was found between productivity grant level and year of conclusion of the doctoral degree (p = 0.10). Median (interquartile range) of scientific articles was 119 (37-312). The prevalence of citations (57.52%) and JCR articles (62.76%) was higher among female researchers. In conclusion, CNPq research productivity grant holders in pediatric dentistry are essentially represented by females from the southeast region of the country (UFMG and USP). However, males have proportionally greater productivity.
  • Effect of horizontal slot of maxillary canines’ brackets with varying wire angulations - An in vitro study Article

    Cantarelli, Márcio Crestana; Godoi, Ana Paula Terossi de; Sinhoreti, Mário Alexandre Coelho; Neves, José Guilherme; Santos, Eduardo Almada; Correr-Sobrinho, Lourenço; Costa, Ana Rosa

    Resumo em Português:

    Resumo Foi desenvolvido um novo dispositivo para permitir a visualização e medição da angulação canina ao mesmo tempo que se visualiza e mede a força transmitida aos dentes adjacentes. Este estudo avaliou o ângulo de inclinação mesiodistal dos braquetes caninos superiores, a deflexão do fio, e os seus efeitos nos dentes adjacentes com cinco diferentes desenhos de ranhuras dos caninos superiores. Os fios (0,020" e 0,019" x 0,025") foram testados em cinco diferentes tipos de braquetes e ângulos distais. A força aplicada aos dentes adjacentes foi medida a medida que o ângulo era aumentado, e as suas consequências foram observadas também nas regiões posterior e anterior. A tensão da força (gf) foi medida em uma máquina de ensaio universal (Instron). Os dados foram submetidos ao teste ANOVA 3 fatores e Tukey (α=0,05). Para ambos os arcos, independentemente do tipo de dente e tipo de braquete, os valores médios de tensão mais elevados foram mostrados pelo ângulo de 20°, seguido pelos ângulos de 15°, 10°, e 5°, que diferiram estatisticamente entre si. Em geral, para ângulos de 5°, 10° e 15°, os braquetes convencionais e versáteis apresentaram valores de força significativamente mais elevados em todos os dentes, braquetes tip-edge e controle apresentaram os mais baixos. Os maiores valores de força foram observados nos incisivos centrais e laterais com braquetes convencionais e versáteis e no primeiro e segundo pré-molares com braquetes auto-ligantes passivo e controle. Os braquetes convencionais apresentaram as forças mais elevadas, os braquetes controle e tip-edge apresentaram os valores mais baixos. Os dentes que sofreram as maiores forças foram os incisivos laterais, e os que sofreram menos foram os segundos pré-molares.

    Resumo em Inglês:

    Abstract A new device was developed to enable the visualization and measurement of canine angulation while at the same time visualizing and measuring the force transmitted to adjacent teeth. This study aimed to evaluate the mesiodistal tilt angle of the upper canine brackets, the wire deflection, and its effects on adjacent teeth with five different slot designs of upper canines. Wires (0.020” and 0.019” x 0.025”) were tested on different five bracket types at five different distal angles. The force applied to adjacent teeth was measured as the angle was increased, and its consequences were observed in the posterior and anterior regions as well. The force tension (gf) was measured in a universal testing machine. Data were submitted to a 3-way ANOVA and Tukey’s test (α=0.05). For both arches, regardless of the type of tooth and bracket type, the highest means tension mean values were shown by the 20° angle, followed by the 15°,10°, and 5° angles, which differed statistically among themselves. Overall, for 5°, 10°, and 15° angles, conventional and versatile brackets showed significantly higher force values in all teeth, tip-edge and control brackets showed the lowest. The highest force values were observed in central and lateral incisors with conventional and versatile brackets and on first and second premolar teeth with self-ligating passive and control brackets. Conventional brackets presented the highest forces, tip-edge and control brackets showed the lowest. The teeth that suffered the greatest forces were lateral incisors, and those that suffered the least were second premolars.
  • Higher frequency of specific periodontopathogens in hypertensive patients. A pilot study Article

    Silveira, Taciane Menezes da; Silva, Caroline Fernandes e; Vaucher, Rodrigo de Almeida; Angst, Patrícia Daniela Melchiors; Casarin, Maísa; Pola, Natália Marcumini

    Resumo em Português:

    Resumo A periodontite e a hipertensão arterial são duas das patologias com maior prevalência global, as evidências relatadas até o momento têm sido favoráveis ​​a uma associação entre elas. Este estudo transversal teve como objetivo avaliar e comparar contagem microbiológicas de pacientes hipertensos e normotensos com periodontite. Dados sociodemográficos, comportamentais, de saúde sistêmica e parâmetros clínicos periodontais foram avaliados. Contagens de A. actinomycetemcomitans, P. intermedia, P. gingivalis e F. nucleatum foram realizadas por reação em cadeia da polimerase em tempo real utilizando amostras de biofilme subgengival. Trinta e oito pacientes foram incluídos nesta análise preliminar, divididos em dois grupos: Grupo Normotenso (GN) (n = 14) e Grupo Hipertenso (GH) (n = 24). Pacientes diagnosticados com periodontite compuseram os dois grupos. A análise dos dados foi realizada com nível de significância de 5%. Não houve diferença significativa entre os grupos para o diagnóstico clínico de periodontite. Além disso, os hipertensos apresentaram maior contagem de P. intermedia, P. gingivalis e F. nucleatum quando comparados aos normotensos. Os parâmetros profundidade de sondagem, sangramento à sondagem e contagem de A. actinomycetemcomitans não apresentaram diferenças estatísticas entre os grupos. Com esses resultados preliminares, pode-se concluir que a presença de hipertensão arterial pode estar associada a uma maior quantidade de bactérias periodontopatogênicas de algumas espécies em indivíduos com periodontite.

    Resumo em Inglês:

    Abstract Periodontitis and arterial hypertension are two of the pathologies with the highest global prevalence; evidence reported so far has been favorable to an association between them. This cross-sectional study aimed to evaluate and compare the microbiological counts of hypertensive and normotensive patients with periodontitis. Sociodemographic, behavioral, systemic health data and periodontal clinical parameters were assessed. Counts of A. actinomycetemcomitans, P. intermedia, P. gingivalis and F. nucleatum were performed by real-time polymerase chain reaction using subgingival biofilm samples. Thirty-eight patients were included in this preliminary analysis, divided into two groups: Normotensive Group (NG) (n = 14) and Hypertensive Group (HG) (n = 24). Patients diagnosed with periodontitis composed both groups. Data analysis was performed with significance level of 5%. There was no significant difference between groups for clinical periodontitis diagnosis. In addition, hypertensive individuals had higher P. intermedia, P. gingivalis, and F. nucleatum counts when compared to normotensive individuals. The parameters probing pocket depth, bleeding on probing, and A. actinomycetemcomitans count did not presented statistical differences between groups. With these preliminary results, it can be concluded that the presence of arterial hypertension may be associated with a greater quantity of periodontopathogenic bacterial of some species in individuals with periodontitis.
  • Evaluation of Removal Force in Prosthetic Components of Morse Taper Dental Implants Article

    Santos, Angelo Marcelo Tirado dos; Stabile, Glaykon Alex Vitti; Felizardo, Klissia Romero; Santos Júnior, Sérgio Eduardo Ramos dos; Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Gonini Júnior, Alcides Gonini; Lopes, Murilo Baena

    Resumo em Português:

    Resumo A longevidade da reabilitação protética é determinada pela estabilidade das interfaces implante e pilar. Conexões de cone Morse em restaurações dentárias têm se mostrado eficazes, porém a força de ativação ainda é empírica. Este trabalho comparou a força de ativação e contato interno do sistema cone Morse de acordo com a força de remoção. Oitenta conjuntos, compostos por implantes e pilares protéticos, foram avaliados com diferentes áreas de contato interno; 15,12mm2 (G3.3) e 21,25mm2 (G4.3). Os corpos-de-prova foram ativados a 0° e 30°, com cargas de 10, 20, 40 e 60N. Os corpos de prova foram submetidos ao ensaio de tração e os dados aos testes ANOVA e Tukey (α=0,05). Espécimes representativos foram examinados em MEV. A força de deslocamento do G3.3 (2,15±1,33MPa) não diferiu do G4.3 (1,99±1,03MPa). A ativação a 0º (2,95±0,98MPa) diferiu estatisticamente para 30º (1,19±0,54MPa). A carga de 60N foi estatisticamente superior para G3.3 e não houve diferença estatística entre 20N a 60N no G4.3. Os valores de 10N em 30o e 20N no longo eixo do implante cone morse, independente da área de contato friccional apresentaram o melhor assentamento.

    Resumo em Inglês:

    Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey’s tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.
  • Oral mucoceles: A Brazillian Multicenter Study of 1,901 Cases Article

    Miranda, Georgea Gabriela Barreto; Chaves-Junior, Samuel de Carvalho; Lopes, Matheus Paschoaletto; Rocha, Talytha Barbosa da; Colares, Débora Frota; Ito, Fábio Augusto; Cavalcante, Israel Leal; Cavalcante, Roberta Barroso; Andrade, Bruno Augusto Benevenuto de; Nonaka, Cassiano Francisco Weege; Alves, Pollianna Muniz; Albuquerque-Júnior, Ricardo Luiz Cavalcanti de; Cunha, John Lennon Silva

    Resumo em Português:

    Resumo A mucocele oral (MO) é a lesão mais comum das glândulas salivares menores. O presente estudo teve como objetivo relatar as características clínicas e demográficas de uma grande série de MOs e identificar possíveis variáveis preditivas associadas à taxa de recorrência dessas lesões. Foi realizado um estudo transversal descritivo retrospectivo. Foram analisados 43.754 registros de biópsias de quatro serviços de patologia no Brasil. Todos os casos diagnosticados como MOs foram revisados e dados clínicos e demográficos foram coletados. Participaram do estudo 1.002 mulheres (56,2%) e 782 homens (43,8%), com média de idade de 19,8 ± 16,4 anos (variação: 01-87 anos) e proporção de mulheres para homens de 1,3:1. O lábio inferior (n=1.160; 67,4%) e assoalho da boca (n=172; 10,0%), foram os locais mais acometidos, apresentando-se clinicamente como nódulos (n=978; 79,4%) de superfície lisa (n =428; 77,5%) e coloração normal (n=768, 46,7%). A biópsia excisional foi o tratamento na maioria dos casos (n=1.392; 78,0%). As MOs recorrentes representaram 6,2% de todos os casos diagnosticados (n = 117). As recorrências recorreram mais comumente em pacientes mais jovens (idade < 20 anos) (p < 0,0001), em lesões maiores que 2 cm de diâmetro (p < 0,0001) e naquelas localizadas na superfície ventral da língua (p = 0,0351). Além disso, as taxas de recorrência foram significativamente maiores nos casos tratados com cirurgia a laser do que aqueles com cirurgia convencional utilizando bisturi (p = 0,0005). Pacientes com mucoceles devem ser informados sobre uma possível recorrência, principalmente quando encontrados no lábio ou assoalho bucal de pacientes jovens.

    Resumo em Inglês:

    Abstract Oral mucocele (OM) is the most common lesion of minor salivary glands. The present study aimed to report the clinical and demographic features of a large series of OMs and identify possible predictive variables associated with the recurrence rate of these lesions. A retrospective descriptive cross-sectional study was performed. A total of 43,754 biopsy records from four pathology services in Brazil were analyzed. All cases of OMs were reviewed, and clinical and demographic data were collected. The study comprised 1,002 females (56.2%) and 782 males (43.8%), with a mean age of 19.8±16.4 years (range: 01-87 years) and a 1.3:1 female-to-male ratio. The lower lip (n=1,160; 67.4%), and floor of the mouth (n=172; 10.0%), were the most common affected sites, presenting clinically as nodules (n=978; 79.4%) of smooth surface (n=428; 77.5%) and normal color (n=768, 46.7%). Excisional biopsy was the treatment in most cases (n=1,392; 78.0%). Recurrent OMs represented 6.2% of all diagnosed cases (n=117). OMs recurred more commonly in younger patients (aged<20 years) (p<0.0001), in lesions larger than 2 cm in diameter (p<0.0001), and in those located in the ventral tongue (p=0.0351). Also, recurrence rates were higher significantly in cases treated with laser surgery than in those with conventional surgery (p=0.0005). Patients with OMs should be carefully informed of its possible recurrence, especially when found on the ventral tongue of young patients.
  • Immunohistochemical analysis of SHH, SMO and GLI-1 proteins in epithelial odontogenic lesions Article

    Rodrigues, Katianne Soares; Santos, Hellen Bandeira de Pontes; Morais, Everton Freitas de; Freitas, Roseana de Almeida

    Resumo em Português:

    Resumo O presente estudo analisou a expressão de proteínas envolvidas na via de sinalização Sonic Hedgehog (SHH, SMO e GLI-1) em lesões benignas do epitélio odontogênico de comportamento biológico distintos, tais como ceratocistos odontogênicos (CO), ameloblastomas (AMB) e tumores odontogênicos adenomatoides (TOA), com o intuito de identificar o papel destas proteínas na patogênese destas lesões. A amostra foi constituída de 20 CO, 20 AMB e 10 TOA, analisada pela técnica da imuno-histoquímica de forma semiquantitativa por compartimento celular, onde foi feita uma análise da membrana e citoplasma das células nas proteínas SHH e SMO, enquanto que para a proteína GLI-1, foi feita uma análise nuclear e/ou citoplasmática. Para análise estatística, foram utilizados os testes de Kruskal-Wallis (KW), Mann-Whitney (U) e Spearman (r), com o nível de significância estabelecido em 5% (p < 0,05). Ao analisar a proteína SHH, observou-se que o AMB demonstrou expressão membranar/citoplasmática significativamente maior em comparação ao TOA (p = 0,022) e CO (p = 0,020). Com relação à análise membranar/citoplasmática da SMO, não foram identificadas diferenças entre as lesões estudadas. Para a proteína GLI-1, foram constatadas diferenças estatisticamente significativas, em nível nuclear, para o AMB e CO em comparação ao TOA (p< 0,0001). Além disso, foram observadas correlações positivas com significância estatística entre GLI-1 citoplasmático e GLI-1 nuclear para o AMB (r = 0,482; p = 0,031) e CO (r = 0,865; p< 0,0001), e entre o SMO membranar/citoplasmático e o GLI-1 citoplasmático para o TOA (r = 0,667; p = 0,035) e o CO (r = 0,535; p = 0,015). Os resultados deste estudo confirmam a participação da via de sinalização Sonic Hedgehog na patogênese das lesões estudadas e, a superexpressão de SHH em AMBs e GLI-1 nuclear em AMBs e COs, indica que estas proteínas contribuem com o comportamento biológico mais agressivo destas duas lesões quando comparado ao TOA.

    Resumo em Inglês:

    Abstract The present study analyzed the expression of proteins involved in the sonic hedgehog signaling pathway (SHH, SMO, and GLI-1) in benign epithelial odontogenic lesions (odontogenic keratocyst - OKC, ameloblastoma - AB, and adenomatoid odontogenic tumor - AOT) in order to identify the role of these proteins in the pathogenesis of these lesions. The sample consisted of 20 OKCs, 20 ABs, and 10 AOTs. The Kruskal-Wallis, Mann-Whitney U, and Spearman’s (r) tests were used for statistical analysis, with the level of significance set at 5% (p < 0.05). The membrane/cytoplasmic expression of SHH was significantly higher in AB compared to AOT (p = 0.022) and OKC (p = 0.02). No differences were found in the membrane/cytoplasmic expression of SMO between the lesions studied. Regarding GLI-1, significant differences were observed at the nuclear level for AB and OKC compared to AOT (p < 0.0001). In addition, significant positive correlations were found between cytoplasmic and nuclear GLI-1 in AB (r = 0.482; p = 0.031) and OKC (r = 0.865; p < 0.0001), and between membrane/cytoplasmic SMO and cytoplasmic GLI-1 in AOT (r = 0.667; p = 0.035) and OKC (r = 0.535; p = 0.015). The results of this study confirm the participation of the sonic hedgehog signaling pathway in the pathogenesis of the lesions studied. Overexpression of SHH in ABs and nuclear expression of GLI-1 in ABs and OKCs indicate that these proteins contribute to the more aggressive behavior of these two lesions when compared to AOT.
  • Effects of argon plasma and aging on the mechanical properties and phase transformation of 3Y-TZP zirconia Article

    Negreiros, William Matthew; Cotta, Monica Alonso; Rueggeberg, Frederick Allen; Bonvent, Jean Jacques; Nascimento, Fabio Dupart; Giannini, Marcelo

    Resumo em Português:

    Resumo Avaliar a resistência à flexão (FS) e o módulo de flexão (FM) de uma cerâmica comercial 3Y-TZP após envelhecimento artificial, e com ou sem dois tempos de aplicação de plasma não térmico (NTP). Além disso, a transformação de fase cristalina e a nano-topografia de superfície após a aplicação de NTP, durante diferentes períodos de envelhecimento, foram avaliadas. Noventa barras 3Y-TZP (45x4x3 mm) foram feitas para testes de FS e FM, e distribuídas em nove grupos (n=10): sem NTP/sem envelhecimento (Controle); sem NTP/4h de envelhecimento; sem NTP/30h de envelhecimento; 10sNTP/sem envelhecimento; 10sNTP/4h; 10sNTP/30h; 60sNTP/sem envelhecimento; 60sNTP/4h e 60sNTP/30h. O envelhecimento artificial acelerado foi simulado em autoclave (134º C a 2 bar) por até 30 horas. FS e FM foram avaliados em máquina de ensaio universal e os dados analisados ​​pela ANOVA e teste de Tukey (α = 0,05). A mudança de volume da fase monoclínica de zircônia (MPV) foi avaliada usando difração de raios-X e nano-topografia de superfície foi avaliada utilizando microscopia de força atômica (baseline até 30h). A aplicação do NTP não influenciou a FS e FM da zircônia. Comparado ao Controle (“sem NTP/sem envelhecimento”), a FS das amostras de zircônia tratadas por 30 horas em autoclave (“sem NTP/30h de envelhecimento”) aumentou. O envelhecimento artificial por 30 horas aumentou significativamente a FM da zircônia, independente do tempo de aplicação do NTP. O MPV tendeu a aumentar em função do aumento do tempo de envelhecimento para todos os grupos, que pode ter resultado nas irregularidades superficiais observadas com 30 horas de envelhecimento. O NTP não afetou as propriedades da zircônia testadas, mas o envelhecimento por 30 horas pode alterar a FS, FM e MPV da zircônia.

    Resumo em Inglês:

    Abstract To evaluate the flexural strength (FS) and flexural modulus (FM) of a commercial 3Y-TZ0P ceramic after artificial aging and either without or with two application times of non-thermal plasma treatments (NTP). In addition, changes in crystalline phase transformation and surface nano-topography after NTP application, during different aging periods, were evaluated. Ninety 3Y-TZP bars (45x4x3 mm) were made for FS and FM testing, and assigned to nine groups (n=10): no NTP/no aging (Control); no NTP/4h aging; no NTP/30h aging; 10s NTP/no aging; 10s NTP/4h aging; 10s NTP/30h aging; 60s NTP/no aging; 60s NTP/4h aging and 60s NTP/30h aging. Artificial accelerated aging was simulated using an autoclave (134º C at 2 bar) for up to 30h. FS and FM were assessed using a universal testing machine and data analyzed using a ANOVA and Tukey test (α=0.05). The volume change in zirconia monoclinic phase (MPV) was evaluated using X-ray diffraction and surface nano-topography was assessed using atomic force microscopy (baseline until 30h-aging). NTP application did not influence the FS and FM of zirconia. Compared to the Control (no NTP/no aging), the FS of zirconia samples treated for 30 hours in autoclave (“no NTP/30h aging” group) increased. Artificial aging for 30 hours significantly increased the FM of zirconia, regardless of NTP application. MPV tended to increase following the increase in aging time, which might result in the surface irregularities observed at 30h-aging. NTP did not alter the zirconia properties tested, but 30h-aging can change the zirconia FS, FM and MPV.
  • Can non-carious cervical lesions depth affect clinical response in pain intensity and remaining dentin thickness? Article

    Galvão, Alexia da Mata; Gonzaga, Ramon Corrêa de Queiroz; Oliveira, Maria Antonieta Veloso Carvalho de; Machado, Alexandre Coelho; Barbosa, Gabriella Lopes de Rezende; Soares, Paulo Vinicius; Silva, Gisele Rodrigues da

    Resumo em Português:

    Resumo Lesões Cervicais Não Cariosas (LCNC) são defeitos do tecido dentário, não relacionados à cárie, frequentemente observados na prática odontológica. O objetivo do estudo foi avaliar os efeitos da profundidade e espessura da dentina de LCNC na resposta à dor dentária por meio de testes de diagnóstico clínico. 86 dentes de 14 pacientes com LCNC foram avaliados por: profundidade da LCNC, testes clínicos (estímulo evaporativo, para detectar níveis de dor de hipersensibilidade dentinária, teste térmico frio para classificar a saúde pulpar, estímulos percussivos para avaliação do tecido perirradicular e tomografia computadorizada de feixe cônico (TCFC), para avaliação da espessura de dentina remanescente (EDR). Em termos de profundidade, a amostra foi dividida em dois grupos: G1- dentes com LCNCs ≤1,0mm e G2- dentes com LCNCs entre 1,1-2,0 mm. Os dados de dor dentária foram comparados pelo teste de Mann-Whitney e a EDR pelo teste t-Student e correlações pelo teste de Pearson (p <0,05). A profundidade da LCNC não influencia a resposta da dor dentária ao estímulo evaporativo (p = 0,129, teste térmico frio (p = 0,125), teste diagnóstico clínico de percussão vertical (p = 0,317) e horizontal (p = 0,119), porém o G1 apresentou maior EDR (p <0,001) e o teste de correlação mostrou que LCNC mais profunda apresenta menor EDR (p = 0,011 / r = -0,273). Conclusão: Dentes com LCNC de até 2mm de profundidade apresenta níveis semelhantes de dor para hipersensibilidade dentinária, pulpar e saúde perirradicular, independente da profundidade da LCNC. Entretanto, lesões com profundidade ≤1,0mmin apresentaram mais EDR nos achados tomográficos.

    Resumo em Inglês:

    Abstract Non-carious Cervical Lesions (NCCL) are dental tissue defects, non-related to caries, frequently observed in the dental practice. The aim of this study was to evaluate the effects of NCCL on dentin depth and thickness and the response to dental pain by means of clinical diagnostic tests. 86 teeth from 14 patients with NCCL were assessed by: depth of NCCL, clinical tests (evaporative stimulus, to detect pain levels of dentin hypersensitivity, cold thermal test to classify pulp health, percussive stimuli to evaluate the periradicular tissues and cone beam computed tomography (tomography to evaluate remaining dentin thickness (RDT). In terms of depth, the sample was divided into two groups: G1- teeth with NCCLs ≤1.0mm and G2- teeth with NCCLs between 1.1-2.0 mm. Dental pain data were compared by Mann-Whitney test and RDT by Student’s t-test and correlations by the Pearson test (p<0.05). The depth of NCCL does not influence dental pain response to evaporative stimulus (p=0.129), cold thermal test (p = 0.125), vertical (p = 0.317) and horizontal (p = 0.119) percussion clinical diagnostic tests. However, G1 showed more RDT (p<0.001), and the correlation test showed that deeper NCCL presents smaller remaining dentin thickness (p=0.011/r=-0.273). In conclusion, tooth with NCCL up to 2mm-depth presents similar levels of pain for dentin hypersensitivity, pulp and periradicular tissue independent to NCCL depth, however, lesions with ≤1.0mm-depth showed greater RDT in tomographic findings.
  • Effect of phytic acid on bond strength and interfacial integrity of universal adhesive to deep dentin Article

    Attia, Ahmed Mostafa; Abo-Elezz, Ahmed Fawzy; Safy, Rehab Khalil

    Resumo em Português:

    Resumo Este estudo investigou o efeito do ácido fítico (IP6) em diferentes concentrações e tempos de aplicação na resistência da ligação microtensiva (µTBS) e na integridade interfacial do adesivo universal à dentina profunda. As superfícies planas de dentina profunda de 48 molares humanos foram preparadas com ácido fosfórico (PA) a 37% durante 15 seg. (controlo); ou não receberam tratamento ácido e o adesivo universal foi aplicado diretamente em modo de auto-adesivo (SE); ou dividido de acordo com a concentração de IP6 (C) em dois grupos principais: C1, 0,5%, e C2, 1%. Os espécimes dos grupos IP6 foram ainda subdivididos em três subgrupos de acordo com o tempo de aplicação do IP6 (T) em que; T1, 15 seg; T2, 30 seg e T3, 60 seg. Aplicou-se então Single Bond Universal Adhesive e construíram-se blocos compostos de resina. Quarenta espécimes foram então seccionados para produzir feixes de resina/dentina que foram usados para testes µTBS usando uma máquina de testes universal. Os restantes oito espécimes foram seccionados em placas que foram imersas em solução amoniacal de nitrato de prata e observou-se uma nano-infiltração utilizando um microscópio eletrônico de varrimento de emissões de campo (FE-SEM). Os resultados mostraram que a aplicação de IP6 em 0,5% e 1% produziu µTBS significativamente mais elevado e menos nano-infiltração em comparação com os grupos PA e SE. Além disso, a aplicação de IP6 durante 60 seg registou o µTBS mais alto e o mais baixo de nano-infiltração seguido de 30 seg, e 15 seg respectivamente. Portanto, o condicionamento da dentina profunda com IP6 melhora o µTBS e a integridade interfacial do adesivo universal à dentina profunda em comparação com a gravação de PA ou utilizando o adesivo universal no modo SE.

    Resumo em Inglês:

    Abstract This study investigated the effect of phytic acid (IP6) in different concentrations and application times on microtensile bond strength (µTBS) and interfacial integrity of universal adhesive to deep dentin. Flat deep dentin surfaces of 48 human molars were either etched with 37% phosphoric acid (PA) for 15 sec (control); or received no acid treatment and universal adhesive was applied directly in a self-etch mode (SE); or divided according to IP6 concentration (C) into two main groups: C1, 0.5%, and C2, 1%. Specimens of IP6 groups were further subdivided into three subgroups according to application time of IP6 (T) where; T1, 15 sec; T2, 30 sec and T3, 60 sec. Single Bond Universal Adhesive was then applied and resin composite blocks were built-up. Forty Specimens were then sectioned to produce resin/dentin beams that were used for µTBS testing using a universal testing machine. The remaining eight specimens were sectioned into slabs that were immersed into ammonical silver nitrate solution and nanoleakage was observed using a field emission scanning electron microscope (FE-SEM). The results showed that the application of IP6 in 0.5% and 1% produced significantly higher µTBS and less nanoleakage compared to PA and SE groups. Also, the application of IP6 for 60 sec recorded the highest µTBS and the lowest nanoleakage followed by 30 sec, and 15 sec respectively. Therefore, conditioning of deep dentin with IP6 enhances µTBS and interfacial integrity of universal adhesive to deep dentin in comparison to PA etching or using the universal adhesive in SE mode.
  • Effect of surrounded shade and specimen`s thickness on color adjustment potential of a single-shade composite Article

    Barros, Mariana Silva; Silva, Paula Fernanda Damasceno; Santana, Márcia Luciana Carregosa; Bragança, Rafaella Mariana Fontes de; Faria-e-Silva, André Luis

    Resumo em Português:

    Resumo Este estudo avaliou o efeito da cor circundante e da espessura da amostra no potencial de ajuste de cor (PAC) de uma resina monocromática. O compósito Vittra APS Unique foi circundado (amostras duplas) ou não (amostras simples) com um compósito controle (cor A1, A2 ou A3). Amostras simples do compósito controle também foram confeccionadas. A opacidade e o índice de brancura para odontologia (IBO) foram calculados para as amostras simples. As diferenças de cor entre amostras simples (ΔE*SIMPLE) / duplas (ΔE*DUAL) e os controles foram calculados. PAC foi calculado baseado na razão entre ΔE* SIMPLE e ΔE* DUAL. O compósito testado apresentou menor opacidade (53 a 62% vs. 80 a 93%) e maior IBO (≈ 42 vs. 18 a 32) que os controles. Independente da espessura da amostra (1,0/ 1,5 mm), os valores mais baixos de ΔE* SIMPLE (11,1/ 10,8) e ΔE*DUAL (7,2/ 6,1) foram observadas quando a resina circundante era A1. A cor A3 resultou em maior ΔE*SIMPLE (16,4/ 17,1) e ΔE* DUAL (11,3/ 12,3) do que A2 (ΔE*SIMPLE = 13,4/ 14,6; e ΔE* DUAL = 9,7/ 10,3). A espessura das amostras afetou significativamente o PAC (0,35 e 0,44 para 1,0 e 1,5 mm, respectivamente) apenas para a cor A1, que teve os maiores valores de PAC. A cor A3 resultou nos maiores valores de PAC (0,31) que A2 (0,27) quando amostras de 1,0 mm de espessura foram usadas, mas valores similares foram observados para amostras de 1,5 mm (≈ 0,29). Como conclusão, tanto a cor circundante como a espessura das amostras podem afetar o PAC de um compósito resinoso monocromático.

    Resumo em Inglês:

    Abstract This study evaluated the effect of surrounded shade and specimens` thickness on the color adjustment potential (CAP) of a single-shade composite. The composite Vittra APS Unique was surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens of the control composite were also confectioned. Opacity and whiteness index for dentistry (WID) were calculated for simple specimens. Color differences between the simple (ΔE*SIMPLE)/ dual specimens (ΔE*DUAL) and the controls were calculated. CAP was calculated based on the ratio between ΔE* SIMPLE and ΔE* DUAL. The tested composite presented lower opacity (53 to 62% vs. 80 to 93%) and higher WID (≈ 42 vs. 18 to 32) than controls. Irrespective of the specimens’ thickness (1.0/ 1.5 mm), the lowest values of ΔE* SIMPLE (11.1/ 10.8) and ΔE*DUAL (7.2/ 6.1) were observed using the surrounding shade A1. The shade A3 yielded higher ΔE*SIMPLE (16.4/ 17.1) and ΔE* DUAL (11.3/ 12.3) than the A2 (ΔE*SIMPLE = 13.4/ 14.6; and ΔE* DUAL = 9.7/ 10.3). The specimen`s thickness significantly affected the CAP (0.35 and 0.44 for 1.0 and 1.5 mm, respectively) only for shade A1, which had the highest CAP values. The shade A3 resulted in higher CAP values (0.31) than A2 (0.27) when 1.0-mm thick specimens were used, but similar values were observed for 1.5 thick specimens (≈ 0.29). In conclusion, both surrounding shade and specimen thickness can affect the CAP of a single-shade resin composite.
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br