Abstract
Artificial bone cements (BCs) based on poly(methyl methacrylate) (PMMA) powders and methyl methacrylate (MMA) liquid monomer also present in their formulation small amounts of other substances, including a chemical initiator compound and radiopaque agents. Because inadequate mixing of the recipe components during the manufacture of the bone cement may compromise the mechanical properties of the final pieces, new techniques to incorporate the fillers into the BC and their effect upon the mechanical properties of BC pieces were investigated in the present study. PMMA powder composites were produced in-situ in the reaction vessel by addition of X-ray contrasts to the reacting MMA mixture. It is shown that this can lead to much better mechanical properties of test pieces, when compared to standard bone cement formulations, because enhanced dispersion of the radiopaque agents can be achieved. Moreover, it is shown that the addition of hydroxyapatite (HA) and acrylic acid (AA) to the bone cement recipe can be beneficial for the mechanical performance of the final material. It is also shown that particle morphology can exert a tremendous effect upon the performance of test pieces, indicating that the suspension polymerization step should be carefully controlled when optimization of the bone cement formulation is desired.
Biomaterials; Artificial bone cement; Radiopaque contrast; Mixing; PMMA; Suspension polymerization
KINETICS AND CATALAYSIS; REACTION ENGINEERING; AND MATERIALS SCIENCE
Production of bone cement composites: effect of fillers, co-monomer and particles properties
J. G. F. Santos Jr.I; V. J. R. R. PitaII; P. A. MeloI; M. NeleIII; J. C. PintoI, * * To whom correspondence should be addressed
IPrograma de Engenharia Química/COPPE, UFRJ, Phone: + (55) (21) 2562-8337, Fax: + (55) (21) 2562-8300, C. P. 68502, 21945-970, Rio de Janeiro - RJ, Brasil
E-mail: jjunior@peq.coppe.ufrj.br; melo@peq.coppe.ufrj.br; pinto@peq.coppe.ufrj.br*
IIInstituto de Macromoléculas, UFRJ, Rio de Janeiro - RJ, Brasil. E-mail: vjpita@ima.ufrj.br
IIIEscola de Química da UFRJ, Rio de Janeiro - RJ, Brasil. E-mail: nele@eq.ufrj.br
ABSTRACT
Artificial bone cements (BCs) based on poly(methyl methacrylate) (PMMA) powders and methyl methacrylate (MMA) liquid monomer also present in their formulation small amounts of other substances, including a chemical initiator compound and radiopaque agents. Because inadequate mixing of the recipe components during the manufacture of the bone cement may compromise the mechanical properties of the final pieces, new techniques to incorporate the fillers into the BC and their effect upon the mechanical properties of BC pieces were investigated in the present study. PMMA powder composites were produced in-situ in the reaction vessel by addition of X-ray contrasts to the reacting MMA mixture. It is shown that this can lead to much better mechanical properties of test pieces, when compared to standard bone cement formulations, because enhanced dispersion of the radiopaque agents can be achieved. Moreover, it is shown that the addition of hydroxyapatite (HA) and acrylic acid (AA) to the bone cement recipe can be beneficial for the mechanical performance of the final material. It is also shown that particle morphology can exert a tremendous effect upon the performance of test pieces, indicating that the suspension polymerization step should be carefully controlled when optimization of the bone cement formulation is desired.
Keywords: Biomaterials; Artificial bone cement; Radiopaque contrast; Mixing; PMMA; Suspension polymerization.
INTRODUCTION
Poly(methyl methacrylate) (PMMA) can be produced through standard solution, suspension and emulsion polymerization processes. PMMA is completely amorphous but has high strength and excellent dimensional stability due to the rigid polymer chains. PMMA has exceptional clarity, very good weatherability and good impact resistance, can be machined and is resistant to most chemicals, although it can be attacked by organic solvents (Odian, 2004). Due to the adequate combination of the mentioned properties, together with its good biocompatibility and ease of manipulation, PMMA is very often used in medical applications, which include the fabrication of internals for blood pumps, blood reservoirs and membranes for blood dialyzers and in vitro diagnostics (Lee et al., 1995). Its optical properties also make PMMA an excellent material for the manufacture of implantable ocular lenses and contact lenses, while its physical and colouring properties make PMMA a good denture material (Park, 1995).
In 1936 it was found that the mixing of ground PMMA powder with liquid monomer resulted in the formation of a doughy material (Kühn, 2000). This is due to the partial dissolution of PMMA in its monomer. Besides, when initiator is added to the mixture, polymer chains that constitute the PMMA powder participate in the free radical polymerization reactions, forming entanglements with newly formed chains. This leads to an intimate chemical connection between the new and the previously formed PMMA chains (Hendriks et al., 2004). Since then, the term bone cement has been used to designate PMMA and methyl methacrylate (MMA) based mixtures (and mixtures with other acrylate compounds), prepared in the presence of initiators. Due to the high viscosity of bone cement mixtures, these blends can be successfully injected into bone cavities in order to correct structural bone failures (Vazquez et al., 1998).
John Charnley was the first physician to use PMMA as an artificial bone tissue in 1958, in surgeries for total hip replacements (Black, 1988). Today, according to the American Academy of Orthopaedic Surgeons (AAOS, 2008), more than 193,000 total hip replacements are performed each year in the United States alone, and similar surgical procedures are performed on other joints, including the knee, shoulder, and elbow. Although small changes have been introduced into the formulation of the basic bone cement material and its usage, since Charnley's pioneering work, bone cement recipes remain essentially the same. The most important change was the addition of X-ray contrasts, like barium sulfate (BaSO4) and zirconium dioxide (ZrO2), to render the bone cement material radiopaque.
The typical PMMA-based bone cement is prepared in the operating room, during the clinical intervention, through the free radical bulk polymerization of MMA monomer, initiated by the decomposition of benzoyl peroxide (BPO) and activated by N,N-dimethyl-p-toluidine (DMPT) (Vazquez et al., 1997). The recipe also contains a prescribed amount of BaSO4 (or ZrO2), used to provide a radiographic contrast during the clinical application of the BC, and PMMA particles, used to increase the initial viscosity of the reaction medium and to accelerate the polymerization reaction due to the gel effect. Typical commercial bone cement brands contain PMMA particles with mean particles sizes in the range 30-150μm, e.g., Simplex P (34 µm), CMW 1 (44 µm), and Palacos R-40 (55 µm) (Planell et al., 1995; Morejón et al., 2005; Liu et al., 2003). The recipe can also be enhanced by the addition of other inorganic fillers, such as hydroxyapatite (HA), as well as co-monomers (such as acrylic acid, AA), to be discussed later, in order to reinforce the final BC piece mechanically (Ogiso et al., 1993), and coloring agents for visualization of the bone cement during the procedure.
The bone cement preparation begins by mixing the recipe components in a vessel (typically a medical bowl). The system viscosity and the reaction rate increase quickly due to the gel effect, which is greatly enhanced by the presence of the PMMA particles. When a suitable viscosity (or degree of polymerization) is reached, the mixture is delivered to the patient. Unfortunately, an inherent problem of this reaction is the great amount of heat released during the bone cement preparation, which may cause the reaction temperature to increase above 100°C, possibly leading to irreparable damage of living tissues (Pascual et al., 1996). However, alternative preparation procedures have been suggested in order to reduce the high temperatures that may be reached during the bone cement preparation, such as the reduction of the operating room temperature (Meyer et al., 1973), the manipulation of the MMA / PMMA ratio (Haas et al., 1975) and the usage of cold chemicals (Dipisa et al., 1976; Toksvig-Larsen et al., 1991; Maffezzoli, 1997).
In order to meet clinical requirements, bone recipe components must undergo sterilization procedures prior to application. The most common sterilization procedures used include gamma irradiation (e.g., as used by the Simplex P brand), ethylene oxide gas (e.g., as used by the Palacos R brand), and formaldehyde tablets (e.g., as used by the Sulfixt-60 and Duracem 3 brands) (Harper And Bonfield, 2000). It should be noted that the mechanical properties of the bone cement can be affected by the choice of the sterilization procedure, as reported by Lewis and Mladsi (1998). More specifically, for the case of the Palacos R brand, Lewis and Mladsi (1998) observed that both weight-average molar masses and fatigue performance of the BC were significantly lower when ethylene oxide gas was applied, probably because of the higher operational temperatures and possible oxidative degradation.
Addition of radiopaque agents into bone cement recipes is necessary for clinical reasons (in order to allow for real time monitoring of the medical intervention). However, due to the very different properties of these inorganic compounds and to the poor compatibility with the polymer matrix, the mechanical behavior of the final pieces can be strongly affected by these materials. Van Hooy-Corstjensa et al. (2004) verified that it is very important to obtain a good contrast distribution throughout the polymeric matrix in order to avoid degradation of the mechanical properties. However, the dispersion of inorganic fillers in the polymer matrix is frequently heterogeneous, so that clumps of inorganic radiopaque agents are often present (Van Hooy-Corstjensa et al., 2004) and can initiate the formation of cracks (Bhambri and Gilbertson, 1995). It has been verified that the presence of small particles of BaSO4 in the BC may result in an increase in the fracture propagation resistance promoted by fatigue (Molino and Topoleski, 1996, Ginebra et al., 2002). Furthermore, it has also been shown that the presence of BaSO4 particles may reduce the tensile strength of the bone cement as compared to radiolucent cements (Ginebra et al., 2002; Haas et al., 1975; Vazquez et al., 1997). As a result, the fatigue life of the bone cement can be drastically lowered. This also means that the presence of these inorganic particles contributes to aseptic loosening of the prosthesis (Krause and Mathis, 1988). Contrast particle size may also play a role in the determination of the mechanical properties of the bone cement. As shown by Bellare et al. (2005), nanocomposite cement recipes, i.e., produced with nanosized BaSO4 particles, have a fatigue life of over twice that of the typical BC.
Therefore, it is well-established that a better dispersion of the radiopaque agents is of fundamental importance to ensure the desired mechanical properties of BC pieces. In the literature it is clear that the dispersion of these agents tends to be inhomogeneous and thus care should be taken to prevent inadequate mixing of the mixture components. In this scenario, new methods to improve dispersion of the radiopaque agents in the BC mixture are of practical interest.
Regarding the commercial method used to incorporate BaSO4 or ZrO2 particles into the BC formulation, one can only rely on the open literature provided by the manufacturers. Because of formulation protection by the manufacturer, information is often limited in scope. However, some brands indicate that BaSO4 or ZrO2 particles are present in the powder in a certain weight fraction (e.g., Simplex®, Orthoset®, Cemfix®, Gentafix®), whereas others either state only that the BaSO4 or ZrO2 particles are provided "premixed" with the powder in a certain weight fraction (e.g., Concert®) or simply do not provide any detailed information regarding this aspect of the recipe (Medcompare, 2008).
The lack of adherence between the inorganic particles and the polymeric matrix is another problem during bone cement formulation. Due to this incompatibility with the polymeric matrix, the contrast forms a segregated phase and makes mixing of reagents more difficult during the preparation. For this reason, some authors have suggested the use of alternative contrasts, such as iodine (Almén, 1995; Davy et al., 1997; Davenport et al., 1999; Ginebra et al., 2002; Nakamura et al., 2003; Artola et al., 2004; Kjellson et al., 2004; Van Hooy-Corstjensa et al., 2004) and/or bismuth (Rawls et al., 1996; Deb et al., 2002) based compounds. These compounds are chemically linked to specially designed monomers and are thus automatically incorporated into the BC formulation. However, because most commercial BC formulations are still based on BaSO4 (or ZrO2) radiopaque contrasts, iodine and bismuth based radiopaque compounds are not investigated in the present manuscript.
In order to increase the mechanical strength and improve the final properties of the bone cement, additives like fibers (Woo et al., 1974; Pilliar et al., 1976; Topoleski et al., 1992), metals (Fishbane and Pond, 1977; Topoleski et al., 1992) and other polymers (Pourdeyhimi and Wagner, 1989, Yang et al., 1997; Vila et al., 1999) have been incorporated and tested in some formulations. The addition of mineral particles has been investigated as well. Among these, hydroxyapatite (HA) can be regarded as an excellent alternative material for reinforcement of the bone cement composites, due to its good biocompatibility with the bone tissue (OGISO et al., 1993). Significant improvements of bone cement properties have been reported in the literature when HA particles are added to typical bone cement formulations (Castaldini and Cavalini, 1986; Perek and Piliar, 1992; Liebendörfer et al., 1995; Vallo et al., 1999).
Harper et al. (1995) reported that up to 40% (w/w) of HA particles can be incorporated in the formulation of BCs, leading to an enhancement of their mechanical strength (in terms of flexural strength and modulus). Similarly, Castaldini and Cavallini (1986) showed that up to 12.5% may be added to the BC recipe, resulting in an increase in the mechanical resistance of the material. Liebendörfer et al. (1995) investigated the in vivo performance of a modified commercial BC formulation by adding 14% (w/w) of HA and verified improvements in biological properties as well as biocompatibility between the BC and biological bone. Perek and Piliar (1992) obtained an increase in the fracture resistance after adding up to 40% (w/w) of HA to the BC recipe. In addition, Lee et al. (1997) showed that by adding 50% (w/w) of HA to the basic BC formulation a better bonding between cement and biological bone is achieved.
Another point of interest during the manufacture of PMMA bone cements regards the presence of a co-monomer in the recipe. It is interesting that the addition of such substances to the bone recipe has been overlooked in the literature, even though many commercial bone recipe kits include co-polymers in their formulation (Hendriks et al., 2004). Co-monomers may be added in small amount to the reaction medium in order to enhance the polymerization rates and the gel effect, thus accelerating the bone cement curing process. Besides, a number of bone cement manufactures utilize high molar mass co-monomers (such as isobornylmethacrylate or n-decyl methacrylate) to reduce the temperature peak in the bone cement preparation (Breusch and Malchau, 2005). Therefore, because of their particular features, the presence of co-monomers in the reaction medium during the production of bone cements is another point of interest to be considered in the present work.
In a previous work, Santos et al. (2006) proposed the in situ incorporation of contrast (and other fillers) during the suspension polymerization performed to produce the PMMA particles. The results obtained showed that the bone cement produced with this PMMA powder is more homogeneous and stronger than the bone cement produced from the hand-mixing of the PMMA and BaSO4 particles during the preparation, here called ex situ preparation.
The objective of the present study is to carry out an experimental investigation to analyze in detail how the in situ contrast (BaSO4 or ZrO2) incorporation and the addition of other components to the recipe (HA, as a filler, and AA, as a co-monomer) affect the mechanical strength of the final bone cement. Moreover, it is also desirable to evaluate the importance of the shape of the PMMA particles on the final performance of the bone cement material. In order to accomplish these objectives, an experimental strategy has been designed to allow for the manipulation of the radiopaque incorporation method (ex situ ´ in situ), the presence of HA and AA in the reaction medium, the average molar mass (MW) and mean particle diameter (DP) of the PMMA powder, and also the shape of these PMMA particles. Different MWs and DPs were tested to allow for a better understanding of their role on the BC mechanical properties investigated. Particles with different morphologies follow the same principle. It is shown that the in situ incorporation of contrasts and fillers during the suspension polymerization process exerts a pronounced beneficial effect on the final performance of the bone cement composites. It is also shown that the use of HA and AA in bone cement formulations can significantly improve the properties of the obtained material.
MATERIALS AND METHODS
Chemicals
Monomer MMA (polymer grade) was provided by Rhodia with a minimum purity of 99.9%. The suspending agent poly(vinyl alcohol) (PVA), with a weight-average molar mass of 78kDa and a degree of hydrolysis of 85%, was supplied by Vetec Química Fina. The initiator (BPO, 97% pure on a dry basis) was supplied by Fluka. The activator (DMPT) was supplied by Aldrich, with 99% purity. BaSO4 was supplied by Vetec Química Fina (97.5% purity). ZrO2 was supplied by Spectrum, with 98% purity. Tetrahydrofuran was supplied by Tedia Brazil, with a minimum purity of 99.9%. Monomer AA (polymer grade) was provided by Rhodia with a minimum purity of 99.9%. Octanol was supplied by Sigma with a minimum purity of 99%. Absolute ethanol P.A was provided by Vetec with a minimum purity of 99.8%. Hydroxyapatite was synthesized by the inverse precipitation method, following Shimoda et al. (1990) and supplied by NUCAT/COPPE/UFRJ. MMA was distilled at reduced pressure. Other chemicals were used as received without additional purification.
PMMA Particle Production and Characterization
Suspension polymerization reactions were performed to produce the PMMA particles used in the BC formulation, as shown in Table 1. Two kinds of suspension polymerization runs were performed: one using pure MMA monomer to produce PMMA powder for the ex situ BC formulation (cf. PMMA grades 1, 2 and 5 in Table 1); and another one using a mixture of MMA monomer and either BaSO4 or ZrO2 to produce a blend of PMMA-radiopaque agent powder for the in situ BC formulation (cf. PMMA grades 3, 4, 6 and 7 in Table 1). Radiopaque agents were added to the reactor vessel as a suspension in the pure MMA monomer. Poly(vinyl alcohol) was used as suspension agent and BPO as initiator. After the production of a given batch of PMMA particles, the reactor content was filtered and washed with distilled water repeatedly and afterwards vacuum dried at room temperature. Since the effluent was found to be limpid and crystalline after each filtration step, the loss of radiopaque agent was considered to be negligible. Finally, particles were classified into different ranges of particles sizes using sets of sieves in an ATM Co. Sonic Sifter and stored.
The conversion level in each experiment presented in Table 2 was determined by taking into account the total amount of MMA added to the reactor and the total amount of dry PMMA particles obtained, assuming total incorporation of radiopaque contrasts, as discussed above. Two conversion values are of particular importance, namely, for PMMA 3, 89.43% (w/w), and PMMA 4, 81.28% (w/w), as these particles are used to produce bone cements by the in situ method and are compared to the test pieces produced by the ex situ method later on in this paper. Therefore, for PMMA 3 and 4, one can calculate that the weight fractions of incorporated contrasts are, approximately, 0.23 and 0.25.
One may notice that different amounts of the BPO polymerization initiator were used in order to produce the PMMA particles with different average molar masses. As discussed previously, the impact of particle morphology, average molar mass and mean diameters on the mechanical properties of the BC are also investigated in this work.
As shown in Table 2, it is possible to group the PMMA grades obtained into two main groups: in the first one, samples present high weight-average molar mass (Mw), including a pure PMMA grade (PMMA 2), a PMMA grade with in situ incorporated BaSO4 (PMMA 3) and a PMMA grade with in situ incorporated ZrO2 (PMMA 4); in the second one, samples present low Mw, including a pure PMMA grade (PMMA 5), a PMMA grade with in situ incorporated BaSO4 (PMMA 6) and a PMMA grade with in situ incorporated ZrO2 (PMMA 7). It should be pointed out here that, except for the reaction designed to produce the grade PMMA 1 in Table 1, all suspension polymerizations were conducted with extremely high agitation frequencies in order to produce irregular polymer particles of different sizes. This was done on purpose, in order to observe whether the morphology of the PMMA powder would affect the final performances of the bone cements. The agitation frequency was carefully designed to produce spherical particles for grade PMMA 1, which has the same weight-average molar mass as grade PMMA 2.
Reactions were carried out in a heated stirred tank glass reactor. An aqueous solution of PVA was added to the reactor. After temperature stabilization, a solution of BPO in MMA monomer (which may contain the suspended BaSO4 or ZrO2 particles) was added to the reactor. Figure 1 shows typical Scanning Electron Microscopy (SEM) analyses of PMMA 3 (left) and PMMA 4 (right), respectively. It can be seen that the surfaces of the PMMA particles are covered by BaSO4 and ZrO2.
Preparation of Bone Cement Test Pieces
Bone cements were produced through free radical bulk polymerization using an initiator (BPO)-activator (DMPT) system. The experimental procedure to obtain the BC test pieces consisted, first, of the preparation of the bone cement mixture and, then, of filling the BC molds. The reactions were carried out in small 50-mL glass vessels. Solid and liquid components were weighed separately. Solid materials were mixed manually before addition of the liquid components. It should be noted here that, if the PMMA powder added to the mixture contained blended radiopaque agents, then the mixing procedure is of the in situ type. Otherwise, if PMMA and radiopaque agent powders were added individually to the mixture, then the mixing is of the ex situ type, as discussed previously. Depending on the formulation, it is possible in this step to add a filler to the mixture, such as HA, or a second liquid monomer, such as AA. In the case of addition of a second monomer, this would be mixed separately with liquid MMA monomer. After preparation of the solid and liquid mixtures, both were mixed manually in glass vessels for about 45-60s until a homogeneous dough was obtained. Mixing was conducted as normally performed in real surgery rooms. After that, the mixture was carefully transferred to the mold in order to avoid formation of air bubbles and reaction was conducted for 30min. Finally, it is important to stress out that the general characteristics of conversion and temperature dynamics during the bone cement reactions described above are similar to those reported by Santos et al. (2006).
Characterization of the Cement Powders and Cured Cements
The weight-average molar mass (Mw) of the polymer samples (either a PMMA powder sample or a BC powder sample) was determined through gel permeation chromatography (GPC). The system was composed of a chromatograph (Waters 600E), three columns (Ultrastyragel) and a refractometer (Waters 2414). The calibration curve was constructed using samples of polystyrene with Mw ranging from 500 to 3´106 Dalton and a polydispersity index lower than 1.05. Tetrahydrofuran was used as the mobile phase and the analyses were carried out at 40°C. The morphology of the PMMA powder particles was determined by optical microscopy (Nikon SMZ 800 stereomicroscope) and scanning electron microscopy (JEOL JSM 5300 microscope). The residual MMA content of the cured cement was determined by using a gas chromatograph (Chrompack CP 9000), calibrated using octanol as the internal standard.
After compression tests, three test pieces were randomly selected to undergo evaluation of residual monomer (MMAR). In order to increase their surface area, the test pieces were frozen with liquid nitrogen for 30s and then carefully smashed to form a powder. This powder was then weighed and delivered to a sealed test tube where an ethanol/octanol solution was added in order to extract the residual monomer content. After 15 days at rest, 0.2 µL samples of this solution were injected into the gas chromatograph, previously calibrated. The relative peaks corresponding to MMA and octanol were then identified to further calculations.
The yield stress or compressive strength (σy) and the Young or compressive modulus of elasticity (E) of the cured cement were determined from compressive tests performed on a servohydraulic universal materials testing machine (Instron, model 4204) using cylindrical specimens (diameter and height of 6mm and 12 mm, respectively, in accordance with ASTM 451-86), with the crosshead displacement rate being 20mm/min.
Statistical Methods
The statistical procedure to treat the measurements of mechanical properties (i.e., Young modulus, E, and yield stress, Σy) simply applied a standard Student t-test to the averages in order to obtain 95% confidence intervals with four degrees of freedom (Pinto and Schwaab, 2007).
RESULTS AND DISCUSSION
The set of experimental runs analyzed in this work is shown in Table 3. The amounts of BPO and DMPT were the same in all runs: 0.075 g and 0.1 g, respectively. In order to represent the different formulations, some abbreviations were adopted, as shown in Table 3. The term "BC" means bone cement, while the subscript abbreviations indicate the added reagents: "H" and "L" indicate high and low Mw, respectively; "D" and "d" indicate the PMMA particle size range, 212-300µm and 75-106µm, respectively; "Ba", "Zr", "AA" e "HA" indicate the addition of barium sulphate, zirconium dioxide, acrylic acid and hydroxyapatite, respectively; the superscript "in" indicates the in situ incorporation of contrasts during the suspension polymerization; the subscripts "sph" indicates the spherical shape; the subscript "mod" indicates that a smaller amount of PMMA was used in the bone cement formulation; and the subscript 15d means that the analysis was performed 15 days after the production of the test piece.
The results obtained from the compression tests (to determine final yield stress, Σy, and Young modulus, E), GPC (to determine weight-average molar masses, Mw, and polydispersion indices, I.P.) and GC analyses (to determine residual monomer content, MMAR) are also presented in Table 3 and show that the final properties of the bone cement can be strongly affected by the reagents' characteristics, as discussed in the following sections.
Influence of the PMMA Powder
Entries 1-12 in Table 3 present some of the characteristics of the final bone cements that are directly related to the PMMA powder. When one compares pairs of experiments with PMMA powders of distinct size (e.g. Entries 1 and 2), it can be observed that this variable does not exert a significant effect on the final yield stress (Σy) and Young modulus (E) of the bone cement test pieces in the analyzed range. In all cases, the confidence intervals of the averages overlap each other, indicating that it is not possible to discriminate between the different values with the adopted confidence level (95%). Therefore, particle sizes should be manipulated for control of the thermal responses during bone cement preparations (Santos et al., 2006), not for control of the mechanical properties of the bone cement.
When one compares pairs of experiments obtained with PMMA powders of distinct weight-average molar masses (e.g., Entries 1 and 7), it can be observed that test pieces prepared with PMMA grades of lower Mw show higher values of Σy and E. It is important to note that the largest differences were obtained for the pair BCH,d / BCL,d (Entries 1 and 7) and the pair BCH,D / BCL,D (Entries 2 and 8), due to the lower Mw of PMMA 5 (compared with PMMA 2, as shown in Table 1). This suggests that the use of a PMMA grade with lower Mw leads to a bone cement with better mechanical properties. This is probably related to the faster solubility of shorter chains in the monomer phase during the reaction, which increases the gel effect, the reaction rates and the size of the newly formed PMMA chains that constitute the polymer matrix. These effects are clearly indicated in Table 3, where one can see the lower contents of residual monomer when PMMA grades of lower Mw are used to prepare the bone cement. Figure 2 illustrates this important result for test pieces prepared with large PMMA particles. It can be seen that MMA conversions are always higher when the bone cements are prepared with the PMMA grades with lower Mw.
The molecular weight analyses performed here concentrated on the molecular weight averages, instead of the full molecular weight distribution, for several reasons. First, the final distributions were always very broad, as one can verify in Table 3, making the final deconvolution (representation of the final MWD as the summation of the MWD of the original PMMA powder and a second MWD curve to be determined) meaningless at times, with computation of multimodal distributions, with modes placed at very distinct molecular weights. Second, the newly formed PMMA chains were subject to strong temperature variations along the batch, due to the almost adiabatic nature of the test piece preparation. As a consequence, deconvolutions performed with the final GPC data could not be unequivocally correlated with the preparation conditions or the original MWD distribution. For these reasons, it was assumed here that the final averages represent the overall system behavior much better than the full deconvoluted MWD.
Figure 3 shows the Mw values of the original PMMA grades and of the respective bone cements prepared with small PMMA particles. It can be observed that smaller differences are observed for bone cements prepared with PMMA grades of low Mw, suggesting that the Mw of the newly formed polymer matrix is indeed larger when the PMMA powder presents lower Mw values. (If one assumes that the Mw of the final bone cement can be computed as the weight-average of the Mw values of the newly formed polymer matrix and of the original polymer powder, Mw values of the matrixes prepared with PMMA grades of low Mw are always larger than the Mw values of the matrixes prepared with PMMA grades of high Mw.)
The effects on the test piece properties caused by the PMMA / MMA ratio and the shape of the PMMA particles are now analyzed. Comparing test pieces BCH,d and BCH,d,mod (Entries 1 and 15), it is possible to conclude that the relative amount of PMMA exerts a pronounced effect on the final properties of the bone cement. The use of smaller amounts of PMMA caused a significant decrease of both σy and E of the final bone cement, as already reported in the literature (Vallo et al., 1998; Belkoff et al., 2002). This is very difficult to explain only in terms of the molecular properties of the bone cement, because the material produced with smaller amounts of PMMA presented higher Mw and lower contents of residual monomer (as also observed by Vallo et al., 1998). Therefore, it may be concluded that the dispersion of the PMMA powder in the polymer matrix is also of fundamental importance for determination of the final properties of the bone cement.
It is important to observe that very little is known about the effect of the morphology of the PMMA particles on the final performance of bone cements. For this reason, two similar formulations, namely, BCH,D and BCH,D,sph (Entries 2 and 19) with PMMA particles of different shapes were analyzed, as shown in Figure 4. The results, presented in Table 3, show very clearly that the use of regular spherical PMMA particles leads to the production of bone cements with improved mechanical properties. The values obtained for both σy and E were much higher when the PMMA particles presented a regular spherical shape. The results are even more impressive when one realizes that sample BCH,D,sph (Entry 19) presented a higher content of residual monomer, suggesting that the morphology of the PMMA particles can affect the final properties of the bone cement very strongly. Therefore, the results presented in Table 3 allow one to conclude that the dispersed PMMA beads exert a tremendous effect on the final performances of the bone cements, which encourages the development of advanced control procedures for the suspension polymerization reactors in which PMMA powders are prepared. The shape of the dispersed PMMA particles certainly affects the distribution of mechanical tensions inside the test piece, which can probably explain the pronounced improvement of the mechanical properties observed here. Therefore, additional investigations should focus on this particular variable in the near future.
Influence of the Contrast Agents
Another important objective of this work was to verify the influence of the in situ contrast incorporation on the final mechanical properties of the bone cement, as proposed in a previous work (Santos et al., 2006). Entries 1 (BCH,d), 3 (BCH,d,Bain), 5 (BCH,d,Zrin), 13 (BCH,d,Ba) and 14 (BCH,d,Zr) in Table 3 show experimental results obtained for test pieces prepared with contrasts incorporated by different techniques. The negative influence of the contrast incorporation on the final properties of the bone cement can be noted when one compares the results obtained for test pieces BCH,d, BCH,d,Ba and BCH,d,Zr. The incorporation of contrasts caused a significant reduction of σy, while E was not significantly affected (probably because of the different elastic properties of the PMMA and of the contrasts). When one compares the results obtained for samples BCH,d,Ba and BCH,d,Zr with the results obtained for samples BCH,d,Bain and BCH,d,Zrin, it can be observed that the in situ incorporation of fillers leads to higher σy values, while E remains essentially constant. It is important to emphasize that the σy values obtained are statistically equivalent to those of the bone cements prepared without contrast (BCH,d). Thus, it can be concluded that the in situ incorporation of the contrast is very beneficial for the final performance of the mechanical properties of the bone cement, as illustrated in Figure 5.
Table 3 also shows that test pieces prepared with contrast agents present lower residual monomer contents and higher Mw values (Entries 3, 5, 13 and 14) when compared with the materials prepared without contrasts (e.g., Entry 1) . However, it is important to consider that these differences were due to the smaller PMMA / MMA ratio, as part of the PMMA powder was replaced by contrast in these formulations (cf. Table 3). On the other hand, it is possible to compare the amount of residual monomer for the test pieces produced via the in situ incorporation of contrast agents (cf. Entries 3 and 5) with those produced via the ex situ technique (cf. Entries 13 and 14). The values of residual monomer are slightly higher for the in situ incorporation technique for the case of BaSO4 contrast, but are the same for the case of ZrO2 contrast. Therefore, one may conclude that the influence of ex situ and in situ incorporation of contrast agents on the residual monomer contents in the final bone cement pieces is not significant.
Influence of Additives, Curing Time and Comonomer
The influence of the addition of HA and AA in the recipe, as well as the curing time (measured from the beginning of the reaction until the performance of the compression test) on the final mechanical behavior of the bone cement were also investigated. The results are shown in Entries 1 (BCH,d), 15 (BCH,d,mod), 16 (BCH,d,AA,mod), 17 (BCH,d,HA) and 18 (BCH,d,HA,15d) in Table 3.
The positive influence of both HA and AA on the mechanical properties of the bone cement can be clearly observed. For the case of HA addition, σy and E values increased 25% and 45%, respectively (cf. BCH,d ´ BCH,d,HA), whereas for the case of AA addition, σy and E values increased 60% and 55%, respectively (cf. BCH,d,mod ´ BCH,d,AA,mod). It is important to note that the bone cements with HA and AA showed higher residual monomer contents, when compared to the materials prepared without these components. In spite of this, the modified bone cements presented better mechanical properties and higher Mw. This confirms the positive influence of both HA and AA on the bone cement. One must observe the significant increase of the Mw values when either HA or AA are added to the recipe. This certainly indicates that HA interacts with the reacting MMA monomer and that the properties of the polymer matrix are fundamental for a proper understanding of the performance of bone cement materials.
In order to verify how the mechanical properties of the bone cement vary with time, one formulation (BCH,d,HA,15d, Entry 18 in Table 3) was analyzed 15 days after the start of the bone cement preparation reaction. The results obtained for this test piece show that the final mechanical properties of the bone cement become much better after some time, probably due to the reduction of the amount of residual monomer and additional production of polymer (the polymerization reaction continues at lower rates at longer times). This clearly indicates that the proposed ASTM standards are conservative, since the bone cement properties improve significantly with time.
CONCLUSIONS
The results presented here show that the addition of HA and AA to bone cement recipes can be beneficial for improvement of the mechanical performance of the prepared material. GC and GPC analyses indicate that these components take part in the reaction and modify the properties of the polymer matrix formed. It was also observed that the PMMA morphology is a very important process variable and the results indicate that the use of spherical PMMA particles can significantly improve the properties of the final bone cement. Finally, it was shown that it is possible to add the contrast to the bone cement formulation without causing significant degradation of the final mechanical properties if in situ contrast incorporation is adopted during the suspension polymerization,, as suggested by SANTOS et al. (2006).
ACKNOWLEDGMENTS
The authors thank the CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico, for providing scholarships and supporting our work.
(Submitted: August 21, 2010 ; Revised: December 9, 2010 ; Accepted: December 14, 2010)
- AAOS, in: http://orthoinfo.aaos.org/topic.cfm?topic=A00377 (Accessed on May 9th 2008).
» link - Almén, T., Visipaque - A Step Forward. A Historical Review. Acta Radiol. Suppl., 399, 2-18 (1995).
- Artola, A., Gurruchaga, M., Vázquez, B., San Roman, J. and Goñi, I., Elimination of Barium Sulphate from Acrylic Bone Cements. Use of Two Iodine Containing Monomers. Biomaterials, 24, 4071-4080 (2004).
- Belkoff, S. M., Sanders, J. C. and Jasper, L. E., The Effect of the Monomer-to-Powder Ratio on the Material Properties of Acrylic Bone Cement. J. Biomed. Mater. Res., Part B, 63, (4), 396-399 (2002).
- Bellare, A., Turell, M. E., Gomoll, A. and Thornhill, T.S., Fatigue Fracture of Poly(Methyl Methacrylate) Bone Cement Containing Radiopacifier Nanoparticles. 11th International Conference on Fracture, Turin, Italy, 20-25 March (2005).
- Bhambri, S. K. and Gilbertson, L. N., Micromechanisms of Fatigue Crack Initiation and Propagation in Bone Cements. J. Biomed. Mater. Res., 29, (2), 233-237 (1995).
- Black, J., Polymers, in Orthopaedic Biomaterials in Research and Practice, (Churchill Livingstone Inc., New York, USA) (1988).
- Breusch, S. J. and Malchau, H., The Well-Cemented Total Hip Arthroplasty: Theory And Practice. (Springer, Berlin, Germany) (2005).
- Castaldini, A. and Cavallini, A., Creep Behavior of Composite Bone Cements, in Biological and Biomedical Performance of Biomaterials, Christel, P., Meunier, A. and Lee, A. J. C. (Eds.) (Elsevier Science, Amsterdam, Netherlands), pp. 525-530 (1986).
- Davenport, D., Cohen, M. D., Hanna, M. P., Bugaieski, E. and Heifetz, S. A., Studies of Iodixanol in the Rabbit Lung and Peritoneum, Pediatr. Radiol., 29, 724-730 (1999).
- Davy, K. W. M., Anseau, M. R., Odlyha, M. and Foster, G. M., X-ray Opaque Methacrylate Polymers for Biomedical Applications. Polym. Int., 43, (2),143-154 (1997).
- Deb, S., Abdulghani, S. and Behiri, J. C., Radiopacity in Bone Cements Using an Organo-bismuth Compound. Biomaterials, 23, (16), 3387-3393 (2002).
- Dipisa, J. A., Sih, G. S. and Berman, A. T., The Temperature Problem at the Bone-Acrylic Cement Interface of the Total Hip Replacement. Clin. Orthop. Rel. Res., 121, 95-98 (1976).
- Fishbane, B. M. and Pond, R. B., Stainless Steel Fiber Reinforcement of Polymethylmethacrylate. Clin. Orthop. Rel. Res., 128, 194-199 (1977).
- Ginebra, M. P., Albuixech, L., Fernández-Barragán, E., Aparicio, C., Gil, F. J., San Román, J., Vázquez, B. and Planell, J. A., Mechanical Performance of Acrylic Bone Cements Containing Different Radiopacifying Agents. Biomaterials, 23, (8), 1873-1882 (2002).
- Haas, S. S., Brauer, G. M. and Dickson, G., A Characterization of Poly(methyl methacrylate) Bone Cement. J. Bone Joint. Surg. Am., 57, 380-391 (1975).
- Harper, E. J., Behiri, J. C. and Bonfield, W., Flexural and Fatigue Properties of a Bone Cement Based Upon Polyethylmethacrylate and Hydroxyapatite. J. Mater. Sci. Mater. Med., 6, (12), 799-803 (1995).
- Harper, E. J. and Bonfield, W., Tensile Characteristics of Ten Commercial Acrylic Bone Cements. J. Biomed. Mater. Res., Part B, 53, (5), 605-616 (2000).
- Hendriks, J. G. E., Van Horn, J. R., Van Der Mei, H. C. and Busscher, H. J., Backgrounds of Antibiotic-Loaded Bone Cement and Prosthesis-Related Infection. Biomaterials, 25, (3), 545-556 (2004).
- Kjellson, F., Almén, T., Tanner, K. E., Mccarthy, I. D. and Lidgren, L., Bone Cement X-Ray Contrast Media: a Clinically Relevant Method of Measuring their Efficacy. J. Biomed. Mater. Res., Part B, 70, 354-361 (2004).
- Krause, W. and Mathis, R. S., Fatigue Properties of Acrylic Bone Cements: Review of the Literature. J. Biomed. Mater. Res., 22, 37-53 (1988).
- Kühn, K-D., Bone Cements: Up-to-date Comparison of Physical and Chemical Properties of Commercial Materials. (Springer-Verlag, Berlin, Germany) (2000).
- Lee, H. B., Kim, S. S. and Khang, G., Polymeric Biomaterials. in The Biomedical Engineering Handbook, Bronzino, J. D., (Eds.) (CRC Press Inc., Boca Raton, Florida, USA), pp. 581-597 (1995).
- Lee, R. R., Ogiso, M., Watanabe, A. and Ishihara, K., Examination of Hydroxyapatite Filled 4-META/MMA-TBB Adhesive Bone Cement in In Vitro and In Vivo Environment. J. Biomed. Mater. Res., Part B, 38, (1), 11-16 (1997).
- Lewis, G. and Mladsi, S., Effect of Sterilization Method on Properties of Palacos® R Acrylic Bone Cement. Biomaterials, 19, 117-124 (1998).
- Liebendörfer, A., Schmitz, B., Wenz, R., Specht, R., Bonath, K., Experimental Studies on a New Bone Cement: Hydroxyapatite Composite Resin in The 21st Annual Meeting of the Society for Biomaterials, (San Francisco, USA), pp. 335 (1995).
- Maffezzoli, A., Ronca, D., Guida, G., Pochini, I. and Nicolais, L., In-situ Polymerization Behaviour of Bone Cements. J. Mater. Sci. Mater. Med., 8, (2), 75-83 (1997).
- Medcompare, in: http://www.medcompare.com/matrix.asp?catid=1635 (Accessed on May 9th 2008).
» link - Meyer, P. R., Lautenschlager, E. P. and Moore, B. K., On the Setting Properties of Acrylic Bone Cement. J. Bone Joint Surg., 55: 149-156 (1973).
- Molino, L.N. and Topoleski, L.D., Effect of BaSO4 on the Fatigue Crack Propagation Rate of PMMA Bone Cement. J. Biomed. Mater. Res., 31, (1), 131-137 (1996).
- Morejón, L., Mendizábal, E., Delgado, J. A., Davidenko, N., López-Dellamary, F., Manríquez, R., Ginebra, M. P., Gil, F. J. and Planell, J. A., Synthesis and Characterization of Poly (Methyl Methacrylate-Styrene) Copolymeric Beads for Bone Cements. Lat. Am. Appl. Res., 35, 175-182 (2005).
- Nakamura, M., Uozumi, J., Soejima, K., Kanou, T., Tokuda, N. and Naito, S., Inhibition of Gluconeogenesis and p-Aminohipuric Acid Accumulation in Rat Renal Cortical Slices by Ionic and Nonionic Contrast Media. Clin. Exp. Nephrol., 7, 98-103 (2003).
- Odian, G., Principles of Polymerization. (John Wiley & Sons, New Jersey, USA) (2004).
- Ogiso, M., Tabata., T., Ichijo, T. and Borgese, D., Bone Calcification on the Hydroxyapatite Dental Implant and the Bone-Hydroxyapatite-Interface. J. Long-Term Effects Med. Implants, 2, 137-148 (1992).
- Park, J. B., Biomaterials in The Biomedical Engineering Handbook. Bronzino, J. D., (Eds.) (CRC Press Inc., Boca Raton, Florida, USA), pp. 529-536 (1995).
- Pascual, B., Vázquez, B., Gurruchaga, M., Goñi, I., Ginebra, M. P., Gil, F. J., Planell, J. A., Levenfeld, B. and San Román. J., New Aspects of the Effect of Size and Size Distribution on the Setting Parameters and Mechanical Properties of Acrylic Bone Cements. Biomaterials, 17, (5), 509-516 (1996).
- Planell, J. A., Vila, M. M., Gil, F. J. and Driessens, F. C. M., Acrylic Bone Cements, in Encyclopedic Handbook of Biomaterials and Bioengineering, Part B: Applications. Wise, D. L., Trantolo, D. J., Altobelli, D. E., Traszewski, M. J., Gresser, J. D. and Schwants, E. R. (Eds.) (Publisher Marcel Dekker Inc., New York, USA), pp. 879-921 (1995).
- Perek, J. and Pilliar, R. M., Fracture Toughness of Composite Acrylic Bone Cements. J. Mater. Sci. Mater. Med., 3, (5), 333-344 (1992).
- Pilliar, R. M., Blackwell, R., Macnab, I. and Cameron, H. U., Carbon Fiber Reinforced Bone Cement in Orthopedic Surgery. J. Biomed Mater. Res., 10, (6), 893-906 (1976).
- Pinto, J. C. and Schwaab, M., Análise de Dados Experimentais I. Fundamentos de Estatística e Estimação de Parâmetros. (E-Papers, Rio de Janeiro, Brazil) (2007).
- Pourdeyhimi, B. and Wagner, H. D., Elastic and Ultimate Properties of Acrylic Bone Cement Reinforced with Ultra-High-Molecular-Weight Polyethylene Fibers. J. Biomed. Mater. Res., 23, (1), 63-80 (1989).
- Rawls, H. R., Granier, R. J., Smid, J. and Cabasso, I., Thermomechanical Investigation of Poly(methylmethacrylate) Containing an Organo-Bismuth Radiopacifying Additive. J. Biomed. Mater. Res., Part A, 31, (3), 339-343 (1996).
- Santos, J. G. F., Peixoto, L. S., Nele, M., Melo, P.A. and Pinto, J. C., Theoretical and Experimental Investigation of the Production of PMMA-Based Bone Cement. Macromol. Symp., 243, (1), 1-12 (2006).
- Shimoda, S., Aoba, T., Moreno, E.C. and Miake, Y., Effect of Solution Composition on Morphological and Structural Features of Carbonated Calcium Apatites. J. Dental Res., 69: 1731-1740 (1990).
- Toksvig-Larsen, S., Franzen, H. and Ryd, L., Cement Interface Temperature in Hip Arthroplasty. Acta Orthop. Scand., 62, (2), 102-105 (1991).
- Topoleski, L.D.T., Ducheyne, P. and Cuckler, J.M., The Fracture Toughness of Titanium-Fiber-Reinforced Bone Cement. J. Biomed. Mater. Res., 26, (12), 1599-1617 (1992).
- Vallo, C. I., Montemartini, P. E. and Cuadrado, T. R., Effect of Residual Monomer Content on Some Properties of a Poly(methyl methacrylate)-Based Bone Cement, J. Appl. Polym. Sci., 69, (7), 1367-1383 (1998).
- Vallo, C. I., Montemartini, P. E., Fanovich, M. A., López, J. M. P. and Cuadrado, T. R., Polymethylmethacrylate-Based Bone Cement Modified with Hydroxyapatite. J. Biomed. Mater. Res. Part B, 48, (2), 150-158 (1999).
- Van Hooy-Corstjens, C. S. J., Govaert, L. E., Spoelstra, A. B., Bulstra, S. K., Wetzels, G. M. R. and Koole, L. H., Mechanical Behaviour of a New Acrylic Radiopaque Iodine-Containing Bone Cement. Biomaterials, 25, (13), 2657-2667 (2004).
- Vazquez, B., Deb, S. and Bonfield, W., Optimization of Benzoyl Peroxide Concentration in an Experimental Bone Cement Based on Poly(methyl methacrylate). J. Mater. Sci. Mater. Med., 8, (7), 455-460 (1997).
- Vazquez, B., Levenfeld, B. and San Roman, J., Role of Amine Activators on the Curing Parameters, Properties and Toxicity of Acrylic Bone Cements. Polym. Int., 46, (3), 241-250 (1998).
- Vila, M. M., Ginebra, M. P., Gil, F. J. and Planell, J. A., Effect of Porosity and Environment on the Mechanical Behavior of Acrylic Bone Cement Modified with Acrylonitrile-Butadiene-Styrene Particles: Part I. Fracture Toughness. J. Biomed. Mater. Res., Part B, 48, (2), 121-127 (1999).
- Woo, S. L-Y., Akeson, W. H., Levenetz, B., Coutts, R. D., Matthews, J. V. and Amiel, D., Potential Application of Graphite Fiber and Methyl Methacrylate Resin Composites as Internal Fixation Plates. J. Biomed Mater Res., 8, (5), 321-338 (1974).
- Yang, J. M., Huang, P. Y., Yang, M. C. and Lo, S. K., Effect of MMA-g-UHMWPE Grafted Fiber on Mechanical Properties of Acrylic Bone Cement, J. Biomed. Mater. Res., Part B, 38, (4), 361-369 (1997).
Publication Dates
-
Publication in this collection
04 July 2011 -
Date of issue
June 2011
History
-
Accepted
14 Dec 2010 -
Reviewed
09 Dec 2010 -
Received
21 Aug 2010