Abstract
A procedure using disposable pipette tips adapted for solid-phase extraction, known as DPX SPE, was used as an alternative way for the chromium determination in wastewater samples. DPX-SPE consists of a device which allows a dynamic contact between the sample and the solid-phase. A residue obtained from the processing of coffee beans, denominate coffee silverskin, was used as a new adsorbent. Characterization techniques revealed properties of lignocellulosic materials with potential application for chromium adsorption. The parameters including adsorbent mass (25.00 mg), elution solvent (0.1 mol L-1 HCl, 200 μL) and pH (2.0) were optimized. Thus, 1.00 mL of deionized water for conditioning, 4.00 mL of sample, 2 extraction cycles and 1 elution cycle were the employed conditions. Enrichment factor of 12, limit of detection of 6.00 µg L-1 and relative standard deviation (RSD) 1.3% (n = 3) were obtained. The method proved to be fast, cheap, environmentally friendly, and simple, providing good recoveries (104-113%), and it was satisfactorily applied in real samples.
Keywords:
chromium; coffee silverskin; DPX; FAAS; SPE; wastewater
Introduction
Chromium is the sixth most abundant element in the earth’s crust, found in natural deposits as ores containing other elements, where it is found in small quantities associated with other metals, particularly with iron as chromite (FeCr2O4) and with lead as crocoite (PbCrO4).11 Augustynowicz, J.; Grosicki, M.; Hanus, E.; Fajerska, M.; Lekka, M.; Koloczek, H.; Chemosphere 2010, 79, 1077.
2 Kumar, P.; Chauhan, M. S.; J. Environ. Chem. Eng. 2019, 7, 103218.-33 Walker, D. B.; Baumgartner, D. J.; Gerba, C. P.; Fitzsimmons, K. In Environmental and Pollution Science, 3rd ed.; Brusseau, M. L.; Pepper, I. L.; Gerba, C. P., eds.; Academic Press: London, 2019, ch. 16, p. 261. It is present in the ecosystem as a result of the weathering of the earth’s crust and deposition of waste from anthropogenic activities. It is an important industrial metal used in alloys such as stainless steel, protective coatings, pigments for paints, cement, paper, rubber, and among another applications.44 Kotaś, J.; Stasicka, Z.; Environ. Pollut. 2000, 107, 263.
5 Tchounwou, P. B.; Yedjou, C. G.; Patlolla, A. K.; Sutton, D. J. In Molecular, Clinical and Environmental Toxicology, vol. 3; Luch, A., ed.; Springer: Basel, 2012, p. 133.-66 Gomes, M. A. C.; Hauser-Davis, R. A.; Suzuki, M. S.; Vitória, A. P.; Ecotoxicol. Environ. Saf. 2017, 140, 55.
Chromium can be found in natural waters in two stable oxidation states, CrIII and CrVI, which present different toxicity. CrIII is an essential nutrient, while the hexavalent form, CrVI, is listed as a known human carcinogen. The presence and ratio between these two forms depend on several processes, including chemical and photochemical redox transformation, precipitation/dissolution, and adsorption/desorption reactions.11 Augustynowicz, J.; Grosicki, M.; Hanus, E.; Fajerska, M.; Lekka, M.; Koloczek, H.; Chemosphere 2010, 79, 1077.
A Brazilian governmental agency responsible for the regulation of contaminants in waters, the National Council of Environment (CONAMA) in resolution number 430/2011, established that the maximum permissible concentration in wastewater is 0.1 mg L-1 for CrVI and 1.0 mg L-1 for CrIII.77 Conselho Nacional do Meio Ambiente (CONAMA); Resolução No. 430, Dispõe sobre As Condições e Padrões de Lançamento de Efluentes, Complementa e Altera a Resolução No. 357, de 17 de março de 2005; Diário Oficial da União (DOU), Brasília, No. 92, de 16/05/2011, p. 89. To ensure that wastewater meets environmental resolutions for disposal in bodies of water, it is necessary to monitor the concentration of contaminating metals. In this scenario, it is important to develop analytical methods that allow the monitoring of chromium and its CrIII and CrVI species, that can be harmful even at low concentrations.
For that matter, several analytical methodologies have been developed for extraction, preconcentration and speciation88 Saygi, K. O.; Tuzen, M.; Soylak, M.; Elci, L.; J. Hazard Mater. 2008, 153, 1009. of chromium in waters, including coprecipitation,99 Karatepe, A.; Korkmaz, E.; Soylak, M.; Elci, L.; J. Hazard. Mater. 2010, 173, 433. liquid-liquid extraction,1010 Béni, Á.; Dávid, N.; Kapitány, S.; Posta, J.; Microchem. J. 2019, 104077. dispersive liquid-liquid microextraction,1111 Shishov, A.; Terno, P.; Moskvin, L.; Bulatov, A.; Talanta 2020, 206, 120209.
12 Tuze, M.; Elik, A.; Altunay, N.; J. Mol. Liq. 2021, 329, 115556.-1313 Ali, J.; Tuzen, M.; Citak, D.; Uluozula, O. D.; Mendil, D.; Kazi, T. G.; Afridi, H. I.; J. Mol. Liq. 2019, 291, 111299. cloud point extraction,1414 Akhtar, A.; Kazi, T. G.; Afridi, H. I.; Khan, M.; Bilal, M.; Khan, N.; J. Ind. Eng. Chem. 2018, 59, 320. and solid-phase extraction.1515 Ghiasi, A.; Malekpour, A.; Microchem. J. 2020, 154, 104530.,1616 Shirani, M.; Salari, F.; Habibollahi, S.; Akbari, A.; Microchem. J. 2020, 152, 104340. The solid-phase extraction (SPE) is a well-known and established technique for extraction and preconcentration of analytical species.1717 Zhao, X.; Song, N.; Zhou, W.; Jia, Q.; Cent. Eur. J. Chem. 2012, 10, 927.,1818 Yao, L.; Zhu, Y.; Xu, W.; Wang, H.; Wang, X.; Zhang, J.; Liu, H.; Lin, C.; J. Ind. Eng. Chem. 2019, 72, 189. It is an ideal technique to concentrate analytes of a liquid matrix, at a trace level, uses a small amount of solvent, and presents good recovery with high enrichment factors. Great attempts have been made to develop new selective and sensitive analytical techniques capable of extracting and/or isolating specific analytes in the most varied matrices.1919 Bordin, D. C. M.; Alves, M. N. R.; de Campos, E. G.; de Martinis, B. S.; J. Sep. Sci. 2016, 39, 1168.,2020 He, M.; Huang, L.; Zhao, B.; Chen, B.; Hu, B.; Anal. Chim. Acta 2017, 973, 1.
A variation of the traditional SPE is the extraction using a disposable pipette tip (DPX: disposable pipette extraction).1919 Bordin, D. C. M.; Alves, M. N. R.; de Campos, E. G.; de Martinis, B. S.; J. Sep. Sci. 2016, 39, 1168. DPX allows rapid extraction of samples and solutions using disposable tips, instead of cartridges or test tubes.2121 Fernandes, V. C.; Domingues, V. F.; Mateus, N.; Matos, C. D.; J. Chromatogr. Sci. 2014, 52, 1339. The DPX technique consists of the modification of a pipette tip (1.0 or 5.0 mL), where a small amount of sorbent is contained therein between two filters. In DPX, samples are mixed with the dispersed sorbent to provide rapid equilibrium by the effective contact between them.1919 Bordin, D. C. M.; Alves, M. N. R.; de Campos, E. G.; de Martinis, B. S.; J. Sep. Sci. 2016, 39, 1168.,2222 Corazza, G.; Merib, J.; do Carmo, S. N.; Mendes, L. D.; Carasek, E.; J. Braz. Chem. Soc. 2019, 30, 1211. The technique has been applied mainly in the determination of food contaminants, drugs, and few publications devoted to metal analytes.2323 Corazza, G.; Merib, J.; Magosso, H. A.; Bittencourt, O. R.; Carasek, E.; J. Chromatogr. A 2017, 1513, 42. However, there are still few studies using DPX for extraction and preconcentration of metallic ions.
Despite the description of the device as disposable tips, the pipette tips can be reused, and the commercial solid phase can be replaced according to interest, which allows the use of alternative materials, so natural adsorbents are a viable and interesting alternative for use in conjunction with DPX.1919 Bordin, D. C. M.; Alves, M. N. R.; de Campos, E. G.; de Martinis, B. S.; J. Sep. Sci. 2016, 39, 1168.,2424 Cadorim, H. R.; Schneider, M.; Hinz, J.; Luvizon, F.; Dias, A. N.; Carasek, E.; Welz, B.; Anal. Lett. 2019, 52, 2133. Thus, the development of new adsorbents with high potential adsorptive, better selectivity or specificity for the target analytes, greater sorption ability, and chemical improvement or physical-mechanical stability is of great interest.2525 Chaves, A. R.; Moura, B. H. F.; Caris, J. A.; Rabelo, D.; Queiroz, M. E. C.; J. Chromatogr. A 2015, 1399. The low-cost natural adsorbent is one of the promising areas of research applied in analytical procedures in the determination of metals in water samples.2626 Alhogbi, B. G.; Sustainable Chem. Pharm. 2017, 6, 21.
These procedures may also be satisfactorily required in the remeasurement of chromium in aqueous systems, including a solid phase functionalization.2727 Liu, F.; Hua, S.; Wang, C.; Qiu, M.; Jin, L.; Hu, B.; Chemosphere 2021, 279, 130539. The exploration of new materials from this class of adsorbents should be increasingly encouraged to promote sustainability in all stages of the procedure. The residues generated during the processing of coffee beans are examples to be used in this proposal.
Coffee is one of the most frequently consumed drinks in the world. According to the International Coffee Organization,2828 International Coffee Organization; https://www.ico.org/ accessed in December 2021.
https://www.ico.org/...
world coffee exports totaled 10.07 million bags in September 2021, compared to 10.59 million bags in September 2020. The coffee bean for consumption goes through industrial processing, which can happen through different processing routes: dry, wet way or semi-wet way.2828 International Coffee Organization; https://www.ico.org/ accessed in December 2021.
https://www.ico.org/...
There are several solid residues generated during different processes. Coffee silverskin is the only by-product produced during the coffee beans roasting process.2929 Durán, C. A. A.; Tsukui, A.; Santos, F. K. F.; Martinez, S. T.; Bizzo, H. R.; Rezende, C. M.; Rev. Virtual Quim. 2017, 9, 107. These residues can be a source of raw material for the food, pharmaceutical, and cosmetic industry, in addition to being frequently used to generate energy in boilers for mechanical dryers and as fertilizers.2828 International Coffee Organization; https://www.ico.org/ accessed in December 2021.
https://www.ico.org/...
,3030 Janissen, B.; Huynh, T.; Resour., Conserv. Recycl. 2018, 128, 110. The coffee silverskin residue is mainly used as fertilizer or fuel, however, studies show that it would be of great use to improve the fiber content in foods and as an antioxidant potential.3131 Alves, V. N.; Neri, T. S.; Borges, S. S. O.; Carvalho, D. C.; Coelho, N. M. M.; Ecol. Eng. 2017, 106, 431.
32 Sanchez, D. A.; Anzola, C.; Rev. Colomb. Quim. 2012, 41, 2.-3333 Souza, J. V. T. M.; Massocatto, C. L.; Diniz, K. M.; Tarley, C. R. T.; Caetano, J.; Dragunski, D. C.; Semina: Cienc. Exatas Tecnol. 2012, 33, 3. The present study will investigate the potential of the coffee silverskin as an adsorbent material.
Thus, this article aimed the use of coffee silverskin as a solid phase in disposable tips (DPX), to the development of a procedure for extraction and preconcentration of chromium in wastewater and detection by flame atomic absorption spectrometry (FAAS). The presented method stands out for showing an alternative solid phase with low cost, an advantageous short extraction time for application in sample preparation.
Experimental
Chemicals, reagents, and sample
All solutions were prepared with ultra-pure deionized water (resistivity of 18.2 MΩ cm) obtained from a purification system (Gehaka, São Paulo, Brazil). Chromium standard solutions with concentrations ranging from 1.0 to 100.0 mg L-1 were prepared by successive dilutions of stock solution 1000.0 mg L-1 (SpecSol Chimlab, Jacareí, Brazil). All plastic vials and used glassware were decontaminated in a 10% v/v HNO3 bath for 10 h, followed by rinsing with deionized water and allowed to dry at room temperature.
In the study of interfering metals, solutions of Ca, Fe, Sr, Ba and Mg were prepared from 1000.0 mg L-1 standard (Carlo Elba, Val de Reuil, France). For each standard chromium solution, known amounts of the interferent to be studied were added in the following proportions in relation to the chromium concentration 1:0.5 and 1:1. To elution, solutions were all prepared at 0.5 mol L-1 from reagents of analytical grade: HCl (Dinâmica, São Paulo, Brazil), NaOH (Synth, São Paulo, Brazil), and HNO3 (Vetec, Duque de Caxias, Brazil).
The water samples were collected at two points in the region of the city of Caldas Novas, Goiás, Brazil. The water (sample 1) represents treated water for supply. The wastewater (sample 2) was collected at one point after the discharge of treated effluent by a conventional effluent treatment plant. The samples were not submitted to any preparation stage. They were only filtered with the aid of syringe filter with polyether sulfone membrane (PES) 0.45 µm, 30 mm (Chromastore, São Paulo, Brazil) to remove solid suspensions and stored under refrigeration (4 ºC) in decontaminated plastic bottles.
Instrumentation
The determination of chromium in the aqueous solutions before and after extraction in DPX using the adsorbent material was performed using a SpectrAA-220 (Varian, Victoria, Australia) flame atomic absorption spectrometer (FAAS). As a radiation source, a hollow cathode lamp (Agilent Technologies, Australia) operated at a specific wavelength line of 425.4 nm, current of 7 mA and spectral slot width of 0.1 nm. The acetylene (White Martins, São Paulo, Brazil) and air flow rates, as well as the burner height, were adjusted to obtain a maximum absorbance signal under the operating conditions, the parameters followed the manufacturer’s recommendations, airflow 300 mL min-1, and signal integration time 5.0 s.
Potentiometric pH measurements were made with a pH meter equipped with a combined glass electrode and Ag/AgCl as the reference electrode, model PG1800 (Gehaka, São Paulo, Brazil).
Adsorbent material
The coffee silverskin obtained from the coffee bean processing industry has varied granulometry. For standardization of the size of the particles, the solid was passed through sieves with a standard opening of 180, 150, and 90 µm, which were manually agitated. Most of the adsorbent material was retained in the 150 µm sieve, which is then the size adopted for the other characterization and adsorption studies.
An initial study of the adsorption of Cr for structural characterization of the coffee silverskin proceeded in batch. The untreated sorbent material (in natura) was placed in contact with the metallic ion solution to evaluate the adsorbent properties. For this, 15.0 mL of chromium solution with a concentration of 1.0 mg L-1 was left in contact with the mass of adsorbent material ranging from 25.0 to 200 mg. The mixtures were kept on a stirring table for an interval of 1 to 50 min. Afterward, each mixture was filtered in a vacuum filtration system, supported on qualitative filter paper (Whatman, Grade 1, 460 mm × 570 mm). To evaluate the adsorption efficiency in these preliminary tests the supernatants were analyzed by FAAS. More information about the results obtained with the batch assays are presented in the Supplementary Information (SI) section (Figures S1 and S2).
Characterization of adsorbent
To determine the zero-load point (pHPCZ), suspensions were prepared with 25.0 mL of deionized water with a previously adjusted pH (initial pH) and 200.0 mg of the adsorbent. pH adjustments were performed by adding solutions of HCl or NaOH 0.10 mol L-1 to obtain initial pH values of 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, and 12. The suspensions were placed in a closed bottle, manually shaken, and remained at rest for 24 h.3434 Nasiruddin Khan, M.; Sarwar, A.; Surf. Rev. Lett. 2007, 14, 461. Then the mixtures were filtered, and the pH of the supernatant was measured, determining the final pH.
The vibrational spectra in the infrared region with Fourier transform (FTIR) were obtained using a PerkinElmer FTIR Frontier Single Range spectrophotometer (Waltham, USA), in the region between 4000 and 500 cm-1. The sample analysis was made in the solid-state, using the attenuated total reflectance (ATR) accessory with the diamond crystal.
The coffee silverskin micrographs from scanning electron microscopy (SEM), were obtained using a scanning electron microscope, model VEGA3 Tescan (Brno, Czech Republic), equipped with an X-ray dispersive energy spectroscopy detector (XR-EDS). Before the analysis, the samples were covered with gold, applying an acceleration voltage of 5.0 kV and the chosen magnifications were 100×, 1000×, 5000× and 10 000×.
Thermogravimetric analysis (TGA) was performed using thermogravimetric analyzer, TGA with DTG detector-60H, series C30574500199TK, Shimadzu (Kyoto, Japan). The TGA curve was obtained in the temperature range from 25 to 600 ºC, at a heating rate of 20 ºC min-1 under an inert nitrogen atmosphere with flow 50 mL min-1.
Solid-phase extraction with a disposable pipette (DPX)
The DPX tips were prepared before each experiment using 25.0 mg of the coffee silverskin as the solid phase. The main extraction parameters were optimized by a univariate study to establish the best adsorption equilibrium condition. During the optimization studies, chromium standard solution with concentration 1.0 mg L-1 was used. This concentration was chosen according to the result of variation of the Cr concentration in the range of 0.5 to 10.0 mg L-1, presented in Figure S3 in the SI section. The Cr solution or sample was aspirated into the tip of the nozzle and the air was then mixed with the adsorbent to form a suspension. After 30 s the solution was dispensed and this process was considered a cycle.3535 Pinto, M. A. L.; Queiroz, M. E. C.; Sci. Chromatogr. 2015, 7, 101.,3636 Tomasin, G. S.; Silva, W. R.; Costa, B. E. S.; Coelho, N. M. M.; Microchem. J. 2021, 161, 105749. The number of cycles to quantitatively remove chromium was evaluated from 2 to 6 cycles and adsorbent mass from 5.0 to 25.0 mg. The influence of the pH on the extraction efficiency was evaluated at the values of pH 2, 4, and 6, by the adjustment with 0.10 mol L-1 HCl or NaOH solutions.2828 International Coffee Organization; https://www.ico.org/ accessed in December 2021.
https://www.ico.org/...
For the chromium elution, HCl, HNO3 and NaOH were evaluated as elution solvents, at different concentrations and volumes. The solvent was sucked into the nozzle, followed by aspiration of air, initially in a single cycle. The number of elution cycles was subsequently checked.3535 Pinto, M. A. L.; Queiroz, M. E. C.; Sci. Chromatogr. 2015, 7, 101.,3636 Tomasin, G. S.; Silva, W. R.; Costa, B. E. S.; Coelho, N. M. M.; Microchem. J. 2021, 161, 105749.
Results and Discussion
Characterization of the adsorbent coffee silverskin
The main functional groups present in the coffee silverskin in natura were characterized by FTIR analysis. The profile of the spectrum is characteristic of lignocellulosic materials and the amount of absorption bands indicates the complex nature of the adsorbent solid, as presented in Figure 1.
The chemical composition of the adsorbent surface influences the adsorption capacity of metals, thus helping to understand the possible interactions between the adsorbent and the analyte.3737 Araújo, C. S. T.; Melo, E. I.; Alves, V. N.; Coelho, N. M. M.; J. Braz. Chem. Soc. 2010, 21, 1727.
38 Bordin, D. C. M.; Alves, M. N. R.; Cabrices, O. G.; de Campos, E. G.; de Martinis, B. S.; J. Anal. Toxicol. 2014, 38, 31.-3939 Yacoub, B. S.; Oudghiri, F.; Belkadi, M.; Barroso, R. R.; J. Therm. Anal. Calorim. 2019, 138, 1801. The broadband centered at 3330 cm-1 is attributed to the stretching of the O-H bond in the protein, fatty acids, carbohydrates, and lignin units. Additionally, due to the protein content present in the coffee silverskin, there is still a contribution due to N-H stretching in the bondage of amides in this region.3232 Sanchez, D. A.; Anzola, C.; Rev. Colomb. Quim. 2012, 41, 2.
The peaks that appear in 2920 and 2840 cm-1 correspond respectively to the asymmetric and symmetric stretching of the C-H bond in the CH2 group, which indicates long chains of alkanes, the basis for the structure of proteins and fibers that are present in plant material.3232 Sanchez, D. A.; Anzola, C.; Rev. Colomb. Quim. 2012, 41, 2. The broadband centered on 1600 cm-1 is an approximate attribution for stretching of carbonyl groups from fatty acid esters and peptide bond of proteins. Bands at 1400 and 1460 cm-1 indicate the aromatic C-C stretching with C-H deformations. The C-O stretch, at 1200 cm-1 is related to lignin content, due to phenolic and ether in guaiacyl units and bands close to 1300 cm-1 are corresponding to the C-O stretching of the syringe structure.4040 Porto, D. S.; Forim, M. R.; Costa, E. S.; Fernandes, J. B.; da Silva, M. F. G. F.; J. Braz. Chem. Soc. 2021, 32, 29. The band at 1000 cm-1 indicates the stretching of C-O, a bond present in alcohol, common in polysaccharides that are part of the composition of plant material.4141 Vaz, S.; Lopes, W. T.; Martin-Neto, L.; Environ. Technol. Innovation 2015, 4, 260.
The overlapping of the FTIR spectra of the adsorbent in natura and containing Cr adsorbed does not show, in principle, changes resulting from specific interactions with the metal ion, which generally occur in wavenumbers below 500 cm-1. However, when the set of bands between 1600 and 1200 cm-1 is compared more carefully, it is possible to notice some subtle changes indicative of the desired adsorption: after adsorption with Cr, there is a better definition of the band at 1540 cm-1. This band may be related to the electronic reallocation of the peptide bond to favor the group -C=NH+. This idea can be confirmed by the disappearance of a small band at 1500 cm-1, attributed to the N-H bond of the secondary amides. Confirmation of this positively charged group contributes to retaining the analyte through non-specific interactions involving the formation of a double electrical layer.
In the in natura sorbent, shoulders located at 1750 and 1476 cm-1 reveal a small portion of carboxylic acid groups, characteristic of the symmetrical elongation of the axial deformation of the deprotonated carboxyl groups.4242 Mudunkotuwa, A. I.; Minshid, A. A.; Grassian, V. H.; Analyst 2014, 139, 870. These shoulders do not appear after adsorption with Cr, suggesting that the electrostatic interactions of a small negatively charged portion in the charge balance of the adsorbent are also responsible for the small adsorption. In this sense, there is also a more pronounced disappearance of the band at 1200 cm-1, indicating the interference of the metal ion in the phenolic structure of the guaiacyl groups of lignin.4040 Porto, D. S.; Forim, M. R.; Costa, E. S.; Fernandes, J. B.; da Silva, M. F. G. F.; J. Braz. Chem. Soc. 2021, 32, 29.
41 Vaz, S.; Lopes, W. T.; Martin-Neto, L.; Environ. Technol. Innovation 2015, 4, 260.
42 Mudunkotuwa, A. I.; Minshid, A. A.; Grassian, V. H.; Analyst 2014, 139, 870.-4343 Santos, A. S.; Santos, T. S. M.; Lemos, V. A.; de Souza, A. O.; J. Braz. Chem. Soc. 2021, 32, 437.
In addition to investigating the functional groups of the material adsorbent surface, it is necessary to evaluate its morphology. A coffee silverskin has a very heterogeneous surface, regions with needle-shaped blocks, and small particle size, as shown in Figure 2. With the increase in magnification, amorphous structures made up of stretched grooves are observed that can contribute to the diffusion of metal ions on the material surface. Porous, irregular, and interstice regions, that facilitate the process of adsorption of metal ions, are also observed in the images.
Images obtained in SEM of the coffee silverskin. Magnifications: (a) 100× (b) 1000× (c) 5000× (d) 10000× (e) adsorption process 5000× (f) adsorption process 10 000×.
The micrographs obtained for the material after the batch adsorption process (Figures 2e and 2f) show a morphological change through the disappearance of the previously observed grooves. This time, the filling of the deformations is noticeable, making the surface more uniform.
Also analyzing the material surface, an estimate of the constituent chemical elements was obtained using the X-ray fluorescence spectra with dispersive energy (XR-EDS). This spectra of the in natura material and after chromium adsorption are shown in Figure S4 of the SI section. The apparent concentration profile of the mapped regions of the adsorbent reveals that the elements C, O, K, and Ca are the majority, varying in that order between 56.5 to 2.82% of the composition. These elements are associated with carbohydrates, fibers, and mineral nutrients. When comparing with the XR-EDS spectrum obtained from the material after adsorption, it is not possible to directly identify the presence of Cr, due to the limitations of low detectability of the equipment (1.0% m/m) under the same experimental conditions. However, it is interesting to note that there is a significant decrease in the alkali metals K and Ca, after adsorption with Cr. These elements have high mobility, and probably could easily be solubilized in the extension of the double electric layer, to accommodate more polarizable metallic elements, as in the case of Cr, which is also susceptible to more efficient coordination with the active sites of the material.
Thermogravimetric analysis (TGA) and derivative thermogravimetry (DTG) were performed to complement information about the structural constitution of the adsorbent. The results confirm the characteristic composition of the class of lignocellulosic adsorbents verified with FTIR. The thermogram and its derivative are shown in Figure S5 of the SI section. The thermal decomposition of coffee silverskin basically occurred in three stages: the first represents the loss of mass by 10% due to the elimination of adsorbed water (0 to 250 ºC). As the coffee silverskin is a residue obtained from the industrial roasting, the material moisture is small. The second stage corresponds to 40% of the mass variation occurring from 250 to 350 ºC. In this temperature range occurs the decomposition of organic matter that make up the protein fraction and fibers present in the plant material. Finally, the third stage involving the temperature range from 350 to 550 ºC signals the decomposition of other components such as: cellulosic and lignin units.4242 Mudunkotuwa, A. I.; Minshid, A. A.; Grassian, V. H.; Analyst 2014, 139, 870.,4444 Alves, V. N.; Coelho, N. M. M.; Microchem. J. 2013, 109, 16.
The evaluation of the zero-load point shows a practically constant range between pH 6 and 9, as presented in Figure 3. In this range, there is a zero-charge point, where the total surface charge is zero. The pHPCZ is defined as the intersection point on the x axis in Figure 3, thereby the pHPCZ of the coffee silverskin was defined at pH 6.4545 Kole, P. L.; Venkatesh, G.; Kotecha, J.; Sheshala, R.; Biomed. Chromatogr. 2011, 25, 199.
In a medium with a pH greater than 6, the coffee film is negatively charged, having the ability to adsorb positively charged species. In a medium with a pH under 5, the plant material is positively charged and can adsorb negative species.
The characteristics presented by the in natura coffee film highlight the promising properties to be explored in metal ion adsorption processes since it has a composition common to other alternative materials investigated for this purpose. Additionally, it is cheaper, as it is an industrial residue and easily obtained.4646 Mendes, M. F.; Freitas, S. S.; Estudos Interdisciplinares em Ciências Exatas e da Terra, 1st ed.; Editora Blucher: São Paulo, 2016, p. 57.
Optimization of DPX steps
The influence of the pH on the chromium adsorption can be evaluated by the extent of protonation/deprotonation equilibrium of acidic functional groups. The pH adjustment was made with 0.10 mol L-1 HCl or NaOH solutions. Buffer solutions could interfere with the chromium adsorption process, due to the competition of the metal ions with the ions present in the buffer for the adsorption sites. In addition to the possibility of complexation of the buffer anions with the analyte.4545 Kole, P. L.; Venkatesh, G.; Kotecha, J.; Sheshala, R.; Biomed. Chromatogr. 2011, 25, 199. The choice of evaluated pH values is considered a range that prevents the removal of chromium by precipitation. pH values of 2, 4 and 6 resulted in 72.0 ± 0.9, 67.0 ± 1.6, and 22.1 ± 0.8% of chromium adsorption, respectively. The most significant extraction occurred at pH 2. The pHPCZ values in the range 6 to 9, indicate amphoteric surfaces, in general, acidic and basic groups of the material surface are affected equally by the pH of the medium, which may contribute to the adsorption of Cr in this condition.
At this pH, CrIII manifests predominantly as a positively charged solvated ion. Note that at first, adsorption is not described by forces of direct electrostatic attraction between the metal ion and the adsorbent. However, it is reasonable to formulate the hypothesis that at pH 2.72 there is an influence of the double electrical layer established on the material surface with the analyte. Under conditions of ionic strength of the medium, the Cr ions can manifest itself as a cluster surrounding a negative ionic atmosphere that diffuses over the water film that makes up the double electrical layer, in a dipole orientation that favors the forces of electrostatic interactions.4747 Pagnanelli, F.; Beolchini, F.; Esposito, A.; Toro, L.; Vegliò, F.; Hydrometallurgy 2003, 71, 201.
48 Michalak, I.; Chojnacka, K.; Witek-Krowiak, A.; Appl. Biochem. Biotechnol. 2013, 170, 1389.-4949 Mishra, A.; Tripathi, B. D.; Rai, A. K.; Ecotoxicol. Environ. Saf. 2016, 132, 420. For CrVI this does not represent a problem since the species manifested negatively charged as HCrO4- in this pH range.4444 Alves, V. N.; Coelho, N. M. M.; Microchem. J. 2013, 109, 16.
The results point out a non-specific adsorption process of Cr concerning the heterogeneous nature of the material. Several studies4747 Pagnanelli, F.; Beolchini, F.; Esposito, A.; Toro, L.; Vegliò, F.; Hydrometallurgy 2003, 71, 201.
48 Michalak, I.; Chojnacka, K.; Witek-Krowiak, A.; Appl. Biochem. Biotechnol. 2013, 170, 1389.-4949 Mishra, A.; Tripathi, B. D.; Rai, A. K.; Ecotoxicol. Environ. Saf. 2016, 132, 420. demonstrate that the interactions of metal ions involving adsorbents of lignocellulosic composition cannot be described only by a single mechanism, but through physical and chemical processes that occur simultaneously interactions. Such processes receive a significant contribution from forces related to chemical interactions as a limiting step of adsorption.5050 Ho, Y. S.; Mckay, G.; Process Biochem. 1999, 34, 451.
For the use of this DPX extraction, each step must be optimized to establish the best equilibrium condition. The conditioning cycle consists of the aspiration and dispensing of 1.0 mL of deionized water, this step serves to compact the solid phase in the tip, as the silver film when transferred is dispersed inside tip.2424 Cadorim, H. R.; Schneider, M.; Hinz, J.; Luvizon, F.; Dias, A. N.; Carasek, E.; Welz, B.; Anal. Lett. 2019, 52, 2133. The dispensed water is taken for reading in the FAAS, this being the analytical blank signal for reference to the obtained supernatants. The tip used in DPX holds up to 5.0 mL of liquid, which allows aspiration of different sample volumes. The evaluated volumes considered that inside the tip, in addition to the solution, space is necessary so that in the air aspiration stage, the sample and the solid phase are well mixed. The volume of solution aspirated for the extraction of Cr influences the analyte dosage available for adsorption. Therefore, a volume of 4.0 mL was chosen.
To evaluate the influence of solid-phase mass, a study was performed with 5.0, 10.0, 20.0, and 25.0 mg of adsorbent. Considering the volume of the sample already defined, the best mass of coffee films to be used was set at 25.0 mg (Figure S6, SI section), which holds a greater number of local assets and, therefore, greater metal ion adsorption. This condition still allows an adequate volume of air in the internal capacity of the device that which provided a more efficient dispersion.
The number of extraction cycles is an important parameter, as it can increase the amount of adsorbed chromium in the solid phase, however it also influences the extraction time, as each cycle takes 30 s.2525 Chaves, A. R.; Moura, B. H. F.; Caris, J. A.; Rabelo, D.; Queiroz, M. E. C.; J. Chromatogr. A 2015, 1399.,3636 Tomasin, G. S.; Silva, W. R.; Costa, B. E. S.; Coelho, N. M. M.; Microchem. J. 2021, 161, 105749.,3838 Bordin, D. C. M.; Alves, M. N. R.; Cabrices, O. G.; de Campos, E. G.; de Martinis, B. S.; J. Anal. Toxicol. 2014, 38, 31. The variation in the number of extraction cycles was evaluated as percentage of adsorption, according to equation 1, where C0 is the initial concentration of chromium (mg L-1) and Ce is the metal concentration in equilibrium (mg L-1), after 30 s.
As presented in Figure 4, there is no significant differences in the values obtained for more than 2 extraction cycles. Considering the total extraction time, 2 cycles become enough for a good removal of the analyte. A higher number of extraction cycles is unnecessary because as the same solution is repeatedly aspirated, the active sites are being filled and with the equilibrium reached it is not possible to increase the removal of Cr.2525 Chaves, A. R.; Moura, B. H. F.; Caris, J. A.; Rabelo, D.; Queiroz, M. E. C.; J. Chromatogr. A 2015, 1399.
Study of the number of solution extraction cycles. Conditions: 25.0 mg of adsorbent in natura; 1.0 mg L-1 Cr solution; 1 conditioning cycle (1.0 mL); sample aspiration (4.0 mL).
For desorption of Cr from the adsorbent surface, 1 mL of 0.5 mol L-1HCl, NaOH, and HNO3 solutions were evaluated, and the results are shown in Figure 5. The best analytical signal in the elution was observed only for the hydrochloric acid, which is therefore the best eluent to be used due to the negative charge on chloride ions. In these conditions, chloride anions have greater affinity with the solid phase than chromium, thus facilitating their exit from the surface of the adsorbent material. A decrease in the signal is observed using HNO3, which may be related to probable oxidation to CrVI and thus favor its adsorption by electrostatic interaction. Using NaOH as an eluent, the lowest signal for Cr desorption was observed in relation to HCl and HNO3. In alkaline solvent, CrIII can form poorly soluble hydroxides, decreasing the extraction efficiency.
Initial study of the elution step. Conditions: 25.0 mg of adsorbent in natura; 1.0 mg L-1 Cr solution with pH 2.0; 1 conditioning cycle (1.0 mL); 2 sample aspiration cycles (4.0 mL); 1 elution cycle (1.0 mL).
As previously mentioned, when choosing the eluent, aggressions to the environment are considered, so diluted acids must be used. Figure 6 shows the results of elution for different concentrations of hydrochloric acid as a function of the analytical signal. Diluted HCl solutions (0.05 and 0.1 mol L-1) showed the best elution efficiency. Thus, the 0.1 mol L-1 concentration was chosen as the best condition for eluting chromium. Since it managed to desorb a larger amount of the metal ion.
Effect of the eluent concentration on chromium elution. Conditions: 25.0 mg of adsorbent in natura, solution 1.0 mg L-1 Cr with pH 2.0; 1 conditioning cycle (1.0 mL); 2 sample aspiration cycles (4.0 mL); 1 elution cycle (1.0 mL).
The preconcentration factor can be improved by decreasing the eluent volume. To achieve the best extraction efficiency with maximum preconcentration effect, the influence of the eluent volume was evaluated, as presented in Figure 7. The smaller evaluated volume (0.2 mL) provided an increase in the analytical signal of approximately 5 times compared to 1.0 mL, and it was selected as the optimum volume. However, this volume permits only 1 elution cycle with effective contact between adsorbent and eluent. The optimized conditions are shown in Table 1.
Influence of the eluent volume. Conditions: 25.0 mg of adsorbent in natura, solution 1.0 mg L-1 Cr pH = 2; 1 conditioning cycle (1.0 mL); 2 sample aspiration cycles (4.0 mL); 1 elution cycle with different volumes.
Interference of concomitant test
In addition to the optimization of the adsorption parameters, the evaluation of concomitant ions that could interfere in the determination of Cr was performed (Ca2+, total Fe, Sr2+, Ba2+, and Mg2+). A known amount of the interferent to be evaluated was added in the following proportions in relation to Cr, 1:0.5; 1:1. After the procedure, the metal was detected by FAAS. The interference factor (FI) was determined, according to the equation 2:
where A’ is the absorbance value relative to the chromium solution in the presence of the interferent and A is the absorbance of the chromium solution without interfering. The results obtained are presented in Table 2. A FI = 1 indicates no interference, FI > 1.1 and FI < 0.9 indicate an increase or decrease in the analytical signal of the analytical signal by the presence of the interfering ion, respectively.5151 Dedina, J.; Anal. Chem. 1982, 54, 2097.
According to the results presented in Table 2, some ions cause interference in the chromium absorbance signal. However, the proportion of analyte:interfering concentration was high in the tests carried out and they are expected to be present at lower concentrations in water samples. The analytical signal variations can be attributed both to the nature of the adsorbent and to specific phenomena of the FAAS technique. It is possible to occur competition of other cations by the adsorption sites; another possibility is based on the complexity of the steps existing in an atomization path, numerous analyte dissociation reactions.5252 Araújo, C. S. T.; Alves, V. N.; Rezende, H. C.; Coelho, N. M. M.; Microchem. J. 2010, 96, 82. Studies5252 Araújo, C. S. T.; Alves, V. N.; Rezende, H. C.; Coelho, N. M. M.; Microchem. J. 2010, 96, 82.
53 Ajlec, R.; Čop, M.; Štupar, J.; Analyst 1988, 4.
54 Bonnefoy, C.; Menudier, A.; Moesch, C.; Lachâtre, G.; Mermet, J. M.; Anal. Bioanal. Chem. 2005, 383, 167.-5555 Zhang, H.; Liu, Q.; Wang, T.; Yun, Z.; Li, G.; Liu, J.; Jiang, G.; Anal. Chim. Acta 2013, 770, 140. indicate that problems related to chemical determinants of chromium can be solved by the addition of ethylenediamine tetraacetic acid (EDTA) as a masking agent for Fe2+, Fe3+, Ca2+, Ba2+ and Mg2+. Under these conditions, Sr2+ does not interfere. The use of a flame composed of nitrous oxide/acetylene can also contribute to reducing this problem.5353 Ajlec, R.; Čop, M.; Štupar, J.; Analyst 1988, 4.
54 Bonnefoy, C.; Menudier, A.; Moesch, C.; Lachâtre, G.; Mermet, J. M.; Anal. Bioanal. Chem. 2005, 383, 167.-5555 Zhang, H.; Liu, Q.; Wang, T.; Yun, Z.; Li, G.; Liu, J.; Jiang, G.; Anal. Chim. Acta 2013, 770, 140.
Figures of merit and analytical results
Calibration curves for chromium have been established with blank and aqueous standard solutions in the concentration range between 0.01 and 2.0 mg L-1. The calibration equation was Abs = 0.063C + 0.0074, where Abs is the absorbance signal and C is the concentration of chromium in mg L-1. Calibration curves in aqueous media and samples fortified with the standard of the analyte (Table 3) showed no significant difference in sensitivity at 95% confidence (p > 0.05). Under the optimized conditions, the linear regression coefficient, the limit of detection (LOD), and limit of quantification (LOQ) were 0.9951, 6.00 μg L-1, and 20.0 μg L-1, respectively, all obtained according to International Union of Pure and Applied Chemistry (IUPAC) guidelines.5656 Templeton, D. M.; Ariese, F.; Cornelis, R.; Danielsson, L.-G.; Muntau, H.; van Leeuwen, H. P.; Lobinski, R.; Pure Appl. Chem. 2000, 72, 1453. Relative standard deviation (RSD) for replicates was estimated at 1.3%. The enhancement factor was calculated as the ratio between the slope of a calibration curve preconcentrated applying the DPX-SPE method and the curve without pre-concentration. An enrichment factor of 12 was achieved by the preconcentration during the extraction procedure. These parameters are relevant to evaluate the performance of an analytical method for the determination of chemical species at sufficiently low concentrations with significant sensitivity improvement. The enrichment factor was already sufficient to obtain adequate LOD to monitor chromium concentrations according to the established standards.
The proposed method was applied to the determination of chromium in wastewater samples. To estimate the recovery efficiency of the method, the suggested procedure was applied in two samples, both samples were fortified with 1.0 mg L-1 Cr solution. The results are shown in Table 3. Before analysis, the sample pH was adjusted at 2. Sample 1 presented Cr below the limit of detection and sample 2 presented chromium concentration within the limits provided by the legislation, showing the analytical viability of the method. Recoveries tests highlight the absence of matrix effect since the values obtained are within the acceptable range of 80 to 120%.5656 Templeton, D. M.; Ariese, F.; Cornelis, R.; Danielsson, L.-G.; Muntau, H.; van Leeuwen, H. P.; Lobinski, R.; Pure Appl. Chem. 2000, 72, 1453.
The recoveries obtained are comparable to values reported in the literature. The adequacy of the DPX SPE method is verified in relation to similar works with other natural adsorbents,4646 Mendes, M. F.; Freitas, S. S.; Estudos Interdisciplinares em Ciências Exatas e da Terra, 1st ed.; Editora Blucher: São Paulo, 2016, p. 57.,5656 Templeton, D. M.; Ariese, F.; Cornelis, R.; Danielsson, L.-G.; Muntau, H.; van Leeuwen, H. P.; Lobinski, R.; Pure Appl. Chem. 2000, 72, 1453. and involving other methods,4646 Mendes, M. F.; Freitas, S. S.; Estudos Interdisciplinares em Ciências Exatas e da Terra, 1st ed.; Editora Blucher: São Paulo, 2016, p. 57.,5656 Templeton, D. M.; Ariese, F.; Cornelis, R.; Danielsson, L.-G.; Muntau, H.; van Leeuwen, H. P.; Lobinski, R.; Pure Appl. Chem. 2000, 72, 1453.,5757 de Souza Neto, J. A.; Oliveira, J. A. N.; Siqueira, L. M. C.; Alves, V. N.; J. Chem. 2019, 2019, 1679419. such as cloud point extraction (CPE)5858 Zhang, L.; Li, X.; Wang, X.; Wang, W.; Wang, X.; Han, H.; Anal. Methods 2014, 6, 5578. and liquid phase derivatization by complexation with ammonium pyrrolidinedithiocarbamate (APDC).5959 Umesh, B.; Rajendran, R. M.; Manoharan, M. T.; Poult. Sci. 2015, 94, 2805. The silverskin coffee used as a new natural solid phase in this work was able to reach a more adequate recovery range compared to what was obtained with a synthetic material based on functionalized silica.6060 Idris, S. A.; Alotaibi, K.; Peshkur, T. A.; Anderson, P.; Gibson, L. T.; J. Colloid Interface Sci. 2012, 386, 344.Table 4 summarizes the comparison between recoveries reported by these works.
Conclusions
The alternative solid-phase extraction based on the DPX method developed in this study provided good sensitivity for the determination of chromium in wastewater samples. The coffee silverskin was efficient in Cr adsorption. LOD was achieved according to the CONAMA established standards. Extraction and preconcentration using DPX is a promising sustainable method, requiring low volumes of sample and diluted HCl solution for elution. The results indicate satisfactory conditions to promote the extraction and sufficient enrichment of chromium by DPX without the need for any chelating agent to favor the interaction with the solid phase. Control of the initial pH of the solution containing the ions of interest was sufficient for sample preparation. Regarding the applicability, the test of accuracy and tests of recovery in samples the values were satisfactory, showing that the method can be applied successfully in water samples and wastewater.
Supplementary Information
Supplementary information is available free of charge at http://jbcs.sbq.org.br as PDF file.
Acknowledgments
The authors are grateful for financial support from the Brazilian Federal Governamental and State funding agencies: Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG) and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES).
References
-
1Augustynowicz, J.; Grosicki, M.; Hanus, E.; Fajerska, M.; Lekka, M.; Koloczek, H.; Chemosphere 2010, 79, 1077.
-
2Kumar, P.; Chauhan, M. S.; J. Environ. Chem. Eng. 2019, 7, 103218.
-
3Walker, D. B.; Baumgartner, D. J.; Gerba, C. P.; Fitzsimmons, K. In Environmental and Pollution Science, 3rd ed.; Brusseau, M. L.; Pepper, I. L.; Gerba, C. P., eds.; Academic Press: London, 2019, ch. 16, p. 261.
-
4Kotaś, J.; Stasicka, Z.; Environ. Pollut 2000, 107, 263.
-
5Tchounwou, P. B.; Yedjou, C. G.; Patlolla, A. K.; Sutton, D. J. In Molecular, Clinical and Environmental Toxicology, vol. 3; Luch, A., ed.; Springer: Basel, 2012, p. 133.
-
6Gomes, M. A. C.; Hauser-Davis, R. A.; Suzuki, M. S.; Vitória, A. P.; Ecotoxicol. Environ. Saf. 2017, 140, 55.
-
7Conselho Nacional do Meio Ambiente (CONAMA); Resolução No. 430, Dispõe sobre As Condições e Padrões de Lançamento de Efluentes, Complementa e Altera a Resolução No. 357, de 17 de março de 2005; Diário Oficial da União (DOU), Brasília, No. 92, de 16/05/2011, p. 89.
-
8Saygi, K. O.; Tuzen, M.; Soylak, M.; Elci, L.; J. Hazard Mater. 2008, 153, 1009.
-
9Karatepe, A.; Korkmaz, E.; Soylak, M.; Elci, L.; J. Hazard. Mater. 2010, 173, 433.
-
10Béni, Á.; Dávid, N.; Kapitány, S.; Posta, J.; Microchem. J. 2019, 104077.
-
11Shishov, A.; Terno, P.; Moskvin, L.; Bulatov, A.; Talanta 2020, 206, 120209.
-
12Tuze, M.; Elik, A.; Altunay, N.; J. Mol. Liq 2021, 329, 115556.
-
13Ali, J.; Tuzen, M.; Citak, D.; Uluozula, O. D.; Mendil, D.; Kazi, T. G.; Afridi, H. I.; J. Mol. Liq 2019, 291, 111299.
-
14Akhtar, A.; Kazi, T. G.; Afridi, H. I.; Khan, M.; Bilal, M.; Khan, N.; J. Ind. Eng. Chem. 2018, 59, 320.
-
15Ghiasi, A.; Malekpour, A.; Microchem. J. 2020, 154, 104530.
-
16Shirani, M.; Salari, F.; Habibollahi, S.; Akbari, A.; Microchem. J 2020, 152, 104340.
-
17Zhao, X.; Song, N.; Zhou, W.; Jia, Q.; Cent. Eur. J. Chem 2012, 10, 927.
-
18Yao, L.; Zhu, Y.; Xu, W.; Wang, H.; Wang, X.; Zhang, J.; Liu, H.; Lin, C.; J. Ind. Eng. Chem. 2019, 72, 189.
-
19Bordin, D. C. M.; Alves, M. N. R.; de Campos, E. G.; de Martinis, B. S.; J. Sep. Sci 2016, 39, 1168.
-
20He, M.; Huang, L.; Zhao, B.; Chen, B.; Hu, B.; Anal. Chim. Acta 2017, 973, 1.
-
21Fernandes, V. C.; Domingues, V. F.; Mateus, N.; Matos, C. D.; J. Chromatogr. Sci. 2014, 52, 1339.
-
22Corazza, G.; Merib, J.; do Carmo, S. N.; Mendes, L. D.; Carasek, E.; J. Braz. Chem. Soc 2019, 30, 1211.
-
23Corazza, G.; Merib, J.; Magosso, H. A.; Bittencourt, O. R.; Carasek, E.; J. Chromatogr. A 2017, 1513, 42.
-
24Cadorim, H. R.; Schneider, M.; Hinz, J.; Luvizon, F.; Dias, A. N.; Carasek, E.; Welz, B.; Anal. Lett. 2019, 52, 2133.
-
25Chaves, A. R.; Moura, B. H. F.; Caris, J. A.; Rabelo, D.; Queiroz, M. E. C.; J. Chromatogr. A 2015, 1399.
-
26Alhogbi, B. G.; Sustainable Chem. Pharm. 2017, 6, 21.
-
27Liu, F.; Hua, S.; Wang, C.; Qiu, M.; Jin, L.; Hu, B.; Chemosphere 2021, 279, 130539.
-
28International Coffee Organization; https://www.ico.org/ accessed in December 2021.
» https://www.ico.org/ -
29Durán, C. A. A.; Tsukui, A.; Santos, F. K. F.; Martinez, S. T.; Bizzo, H. R.; Rezende, C. M.; Rev. Virtual Quim 2017, 9, 107.
-
30Janissen, B.; Huynh, T.; Resour., Conserv. Recycl 2018, 128, 110.
-
31Alves, V. N.; Neri, T. S.; Borges, S. S. O.; Carvalho, D. C.; Coelho, N. M. M.; Ecol. Eng 2017, 106, 431.
-
32Sanchez, D. A.; Anzola, C.; Rev. Colomb. Quim. 2012, 41, 2.
-
33Souza, J. V. T. M.; Massocatto, C. L.; Diniz, K. M.; Tarley, C. R. T.; Caetano, J.; Dragunski, D. C.; Semina: Cienc. Exatas Tecnol. 2012, 33, 3.
-
34Nasiruddin Khan, M.; Sarwar, A.; Surf. Rev. Lett. 2007, 14, 461.
-
35Pinto, M. A. L.; Queiroz, M. E. C.; Sci. Chromatogr. 2015, 7, 101.
-
36Tomasin, G. S.; Silva, W. R.; Costa, B. E. S.; Coelho, N. M. M.; Microchem. J 2021, 161, 105749.
-
37Araújo, C. S. T.; Melo, E. I.; Alves, V. N.; Coelho, N. M. M.; J. Braz. Chem. Soc 2010, 21, 1727.
-
38Bordin, D. C. M.; Alves, M. N. R.; Cabrices, O. G.; de Campos, E. G.; de Martinis, B. S.; J. Anal. Toxicol 2014, 38, 31.
-
39Yacoub, B. S.; Oudghiri, F.; Belkadi, M.; Barroso, R. R.; J. Therm. Anal. Calorim 2019, 138, 1801.
-
40Porto, D. S.; Forim, M. R.; Costa, E. S.; Fernandes, J. B.; da Silva, M. F. G. F.; J. Braz. Chem. Soc. 2021, 32, 29.
-
41Vaz, S.; Lopes, W. T.; Martin-Neto, L.; Environ. Technol. Innovation 2015, 4, 260.
-
42Mudunkotuwa, A. I.; Minshid, A. A.; Grassian, V. H.; Analyst 2014, 139, 870.
-
43Santos, A. S.; Santos, T. S. M.; Lemos, V. A.; de Souza, A. O.; J. Braz. Chem. Soc. 2021, 32, 437.
-
44Alves, V. N.; Coelho, N. M. M.; Microchem. J 2013, 109, 16.
-
45Kole, P. L.; Venkatesh, G.; Kotecha, J.; Sheshala, R.; Biomed. Chromatogr 2011, 25, 199.
-
46Mendes, M. F.; Freitas, S. S.; Estudos Interdisciplinares em Ciências Exatas e da Terra, 1st ed.; Editora Blucher: São Paulo, 2016, p. 57.
-
47Pagnanelli, F.; Beolchini, F.; Esposito, A.; Toro, L.; Vegliò, F.; Hydrometallurgy 2003, 71, 201.
-
48Michalak, I.; Chojnacka, K.; Witek-Krowiak, A.; Appl. Biochem. Biotechnol 2013, 170, 1389.
-
49Mishra, A.; Tripathi, B. D.; Rai, A. K.; Ecotoxicol. Environ. Saf. 2016, 132, 420.
-
50Ho, Y. S.; Mckay, G.; Process Biochem 1999, 34, 451.
-
51Dedina, J.; Anal. Chem. 1982, 54, 2097.
-
52Araújo, C. S. T.; Alves, V. N.; Rezende, H. C.; Coelho, N. M. M.; Microchem. J. 2010, 96, 82.
-
53Ajlec, R.; Čop, M.; Štupar, J.; Analyst 1988, 4.
-
54Bonnefoy, C.; Menudier, A.; Moesch, C.; Lachâtre, G.; Mermet, J. M.; Anal. Bioanal. Chem 2005, 383, 167.
-
55Zhang, H.; Liu, Q.; Wang, T.; Yun, Z.; Li, G.; Liu, J.; Jiang, G.; Anal. Chim. Acta 2013, 770, 140.
-
56Templeton, D. M.; Ariese, F.; Cornelis, R.; Danielsson, L.-G.; Muntau, H.; van Leeuwen, H. P.; Lobinski, R.; Pure Appl. Chem 2000, 72, 1453.
-
57de Souza Neto, J. A.; Oliveira, J. A. N.; Siqueira, L. M. C.; Alves, V. N.; J. Chem. 2019, 2019, 1679419.
-
58Zhang, L.; Li, X.; Wang, X.; Wang, W.; Wang, X.; Han, H.; Anal. Methods 2014, 6, 5578.
-
59Umesh, B.; Rajendran, R. M.; Manoharan, M. T.; Poult. Sci. 2015, 94, 2805.
-
60Idris, S. A.; Alotaibi, K.; Peshkur, T. A.; Anderson, P.; Gibson, L. T.; J. Colloid Interface Sci 2012, 386, 344.
Edited by
Publication Dates
-
Publication in this collection
02 May 2022 -
Date of issue
2022
History
-
Received
21 June 2021 -
Accepted
17 Dec 2021