Acessibilidade / Reportar erro

Development and Validation of a Method to Analyze Fentanyl and Its Analogues in Postmortem Blood Samples by LC-MS/MS

Abstract

The increase in the number of users, hospitalizations and deaths due to overdose of synthetic opioids made the scientific community to treat this problem as “the opioid crisis”, justifying the need for the development of analytical strategies to identify and quantify these drugs. Even with the global discussion, there is no Brazilian data regarding opioids consumption, addiction or fatal intoxication cases. The aim of this work was to develop, validate and applied an analytical method based on liquid chromatography-tandem mass spectrometry for determination of fentanyl and seven analogues (acetyl norfentanyl, acetyl fentanyl, thiofentanyl, acrylfentanyl, furanylfentanyl, carfentanil and valerylfentanyl) in postmortem blood samples, to the routine analysis of the Forensic Toxicology Laboratory of São Paulo State Police. Linearity was evaluated from 1-500 ng mL-1 (correlation coefficient (r) value (r ≥ 0.99), 1/x weight linear regression), with limit of quantification of 1 ng mL-1. The method imprecision, bias and matrix effect were lower than 19.7%. No interference or carryover were observed, and extraction yield was greater than 57.7%. Analysis of postmortem blood samples (n = 1,359) showed that fentanyl was the most frequently detected opioid. The developed method proved to be useful for routine analysis of the Forensic Toxicology Laboratory.

Keywords:
forensic toxicology; fentanyl; opioid crisis; new psychoactive substances; LC-MS/MS


Introduction

New psychoactive substances (NPS) are drugs that mimic the effects of traditional drugs of abuse and can pose a public health threat. These substances or mixtures of psychoactive compounds are produced in clandestine laboratories by chemical synthesis from precursor substances found in nature or not, or through minor modifications in the structure of the molecule that have known biological activity.11 United Nations Office on Drugs and Crime (UNODC); World Drug Report 2015; UNODC: Vienna, Austria, 2015. [Link] accessed in December 2023
Link...
,22 United Nations Office on Drugs and Crime (UNODC), https://www.unodc.org/LSS/Page/NPS, accessed in December 2023.
https://www.unodc.org/LSS/Page/NPS,...
The growing worldwide abuse of an important group of NPS, the synthetic opioids, has led to serious public health problems in several countries, mainly in the United States of America (USA). The significant increase in number of users, and consequently, individuals who became addicted, were hospitalized or died from overdose made the scientific community call this problem “the opioid crisis”, justifying the need for the development of analytical strategies that allow the identification and quantitation of this class of drugs in the human system.

Synthetic opioids include (among other substances) fentanyl and its analogues, which are synthetic agonists of the μ-opioid receptor of the phenylpiperidine class and they are high-potency drugs, approximately 80 to 100 times more potent than morphine.33 Wu, F.; Slawson, M. H.; Johnson-Davis, K. L.; J. Anal. Toxicol. 2017, 41, 289. [Crossref]
Crossref...
,44 Rodda, L. N.; Pilgrim, J. L.; Di Rago, M.; Crump, K.; Gerostamoulos, D.; Drummer, O. H.; J. Anal. Toxicol. 2017, 41, 318. [Crossref]
Crossref...
Toxic effects of these substances include respiratory depression and neurological complications that could lead to seizures; in addition to hypersensitivity reactions probably by immunoglobulin E (IgE)-mediated reactions leading to degranulation of mast cells and basophils, resulting in the release of inflammatory mediators.55 Ruzycki, S.; Yarema, M.; Dunham, M.; Sadrzadeh, H.; Tremblay, A.; J. Med. Toxicol. 2016, 12, 185. [Crossref]
Crossref...
,66 Yamanaka, T.; Sadikot, R. T.; Respirology 2013, 18, 255. [Crossref]
Crossref...
,77 Solé, D.; Spindola, M. A. C.; Aun, M. V. ; Azi, L. A.; Bernd, L. A. G.; Bianchi, D.; Capelo, A. V. ; Cumino, D.; Lacerda, A. E.; Lima, L. C.; Morato, E.; Nunes, R. R.; Rubini, N. P. M.; Silva, J.; Tardelli, M. A.; Watanabe, A. S.; Curi, E. F.; Sano, F.; Arquivos Asma, Alergia Imunol. 2020, 4, 35. [Crossref]
Crossref...
,88 Dewachter, P.; Lefebvre, D.; Kalaboka, S.; Bloch-Morot, E.; Acta Anaesthesiol. Scand. 2009, 53, 1092. [Crossref]
Crossref...
The severity of respiratory depression depends on patient response, pharmacokinetics, ingestion of other sedative medications, and other comorbidities that affect lung function.99 Bakovic, M.; Nestic, M.; Mayer, D.; Int. J. Legal Med. 2015, 129, 1247. [Crossref]
Crossref...

Fentanyl is mixed with heroin to adulterate this drug of abuse, increasing its potency, but users do not know that fentanyl is present. The mix of these two drugs has serious consequences, and could be fatal even for users with a certain level of opioid tolerance, given fentanyl’s potency. Several cases of intoxications and deaths caused by these NPS have been described in the literature.44 Rodda, L. N.; Pilgrim, J. L.; Di Rago, M.; Crump, K.; Gerostamoulos, D.; Drummer, O. H.; J. Anal. Toxicol. 2017, 41, 318. [Crossref]
Crossref...
,1010 Swanson, D. M.; Hair, L. S.; Rivers, S. R. S.; Smyth, B. C.; Brogan, S. C.; Ventoso, A. D.; Vaccaro, S. L.; Pearson, J. M.; J. Anal. Toxicol. 2017, 41, 498. [Crossref]
Crossref...
,1111 Ruan, X.; Chiravuri, S.; Kaye, A. D.; J. Anal. Toxicol. 2016, 41, 163. [Crossref]
Crossref...
,1212 Ruan, X.; Chiravuri, S.; Kaye, A. D.; Forensic Sci., Med., Pathol. 2016, 12, 363. [Crossref]
Crossref...
,1313 Poklis, J.; Poklis, A.; Wolf, C.; Hathaway, C.; Arbefeville, E.; Chrostowski, L.; Devers, K.; Hair, L.; Mainland, M.; Merves, M.; Pearson, J.; J. Anal. Toxicol. 2016, 40, 703. [Crossref]
Crossref...
,1414 McIntyre, I. M.; Trochta, A.; Gary, R. D.; Wright, J.; Mena, O.; J. Anal. Toxicol. 2016, 40, 162. [Crossref]
Crossref...
,1515 Fort, C.; Curtis, B.; Nichols, C.; Niblo, C.; J. Anal. Toxicol. 2016, 40, 754. [Crossref]
Crossref...
,1616 Cunningham, S. M.; Haikal, N. A.; Kraner, J. C.; J. Forensic. Sci. 2016, 61, 276. [Crossref]
Crossref...

In addition to new molecules, fentanyl derivatives that were used in other areas began to be used for recreational purposes. An example is carfentanil, a substance that has a potency 10,000 times higher than morphine, authorized only for veterinary applications (sedating large animals, such as elephants), has been used as a drug of abuse and has caused numerous deaths.1010 Swanson, D. M.; Hair, L. S.; Rivers, S. R. S.; Smyth, B. C.; Brogan, S. C.; Ventoso, A. D.; Vaccaro, S. L.; Pearson, J. M.; J. Anal. Toxicol. 2017, 41, 498. [Crossref]
Crossref...
,1717 United Nations Office on Drugs and Crime (UNODC); Global Smart Update: Fentanyl and its Analogues-50 Years on; UNODC: Vienna, Austria, 2017. [Link] accessed in December 2023
Link...
,1818 Sofalvi, S.; Schueler, H. E.; Lavins, E. S.; Kaspar, C. K.; Brooker, I. T.; Mazzola, C. D.; Dolinak, D.; Gilson, T. P.; Perch, S.; J. Anal. Toxicol. 2017, 41, 473. [Crossref]
Crossref...
,1919 Shanks, K. G.; Behonick, G. S.; J. Anal. Toxicol. 2017, 41, 466. [Crossref]
Crossref...
,2020 Seither, J.; Reidy, L.; J. Anal. Toxicol. 2017, 41, 493. [Crossref]
Crossref...

According to data from Drug Enforcement Administration (DEA),2121 Drug Enforcement Administration (DEA); National Drug Threat Assessment (NDTA); DEA: USA, 2020. [Link] accessed in December 2023
Link...
until 2018, more than 31,000 Americans died from overdose involving synthetic opioids other than methadone, accounting for 67% of opioid-involved deaths. Although several drugs are present in this category, fentanyl is the major responsible for these deaths. Moreover, the National Forensic Laboratory Information System (NFLIS) crime laboratory (NFLIS-Drug) accounted 100,378 fentanyl reports in 2019,2222 National Forensic Laboratory Information System (NFLIS); NFLIS-Drug 2019 Annual Report; U.S. Drug Enforcement: Springfield, United States of America, 2020. [Link] acessed in January 2024
Link...
an increase of 12% compared to 2018. Besides the global discussion about the “opioid crisis”, Brazil has no epidemiological data about consumption, addiction or fatal intoxications by these NPS.

The aim of this work was to develop and validate a method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of fentanyl and 7 analogues (acetyl norfentanyl, acetyl fentanyl, thiofentanyl, acrylfentanyl, furanylfentanyl, carfentanil and valerylfentanyl) in postmortem blood samples. Then, the method was applied to the routine analysis of the Forensic Toxicology Laboratory, Institute of Legal Medicine, São Paulo State Police.

Experimental

Standards and chemicals

Solvents employed in the sample extraction and chromatographic analyses were formic acid (≥ 95%, from Sigma-Aldrich, St Louis, USA), ammonium formate, high performance liquid chromatography (HPLC) grade acetonitrile and methanol from Merck (Darmstadt, Germany), and ultra-pure deionized water was supplied by a Milli-Q RG unit from Millipore (Milford, USA). Reference standards of fentanyl, acetyl fentanyl, valeryl fentanyl, thiofentanyl, acrylfentanyl, furanyl fentanyl, carfentanil and isotopically labeled cocaine (cocaine-d3 used as internal standard) were purchased from Cerilliant (Round Rock, USA) and Cayman Chemical (Ann Arbor, USA).

Calibrators, quality controls and internal standards

Working solutions were prepared by dilution of fentanyl and analog reference materials in methanol, in other to prepare calibrators at 10, 50, 100, 300, 500 and 1000 ng mL-1 and quality control (QC) solutions at three concentrations: low (30 ng mL-1), medium (250 ng mL-1) and high (750 ng mL-1). To prepare the internal standard solution (IS), a cocaine-d3 reference material was diluted in acetonitrile to reach a final concentration of 200 ng mL-1. All solutions were stored at –20 °C in amber glass vials.

Blank postmortem human blood (250 μL) was fortified with 25 μL of calibrators or QC working solutions to achieve 1, 5, 10, 30, 50 and 100 ng mL-1 (calibrators) and 3, 25 and 75 ng mL-1 (QCs).

Instrumentation and LC-MS/MS conditions

The analysis was performed on a Nexera UHPLC chromatographic system coupled to a LCMS-8050 triple quadrupole mass spectrometer (Shimadzu, Kyoto, Japan). The analytes were separated using a Waters Atlantis-T3 column (150 mm × 4.6 mm, 3 μm) maintained at 40 °C, with mobile phase composed by (A) ultra-pure water and (B) methanolic solutions containing 0.1% formic acid and 2 mmol L-1 ammonium formate. The flow rate was set to 0.35 mL min-1 and gradient elution consisted of a linear change in percentage of mobile phase B, from 5 to 95%, holding at 95% B for 2.5 min and returning to 5% over 0.1 min, for a 15.5 min total run time. The mass spectrometer was equipped with an electrospray ionization source, operated in positive mode and source parameters optimized were: heat block temperature 400 °C; ion spray voltage 4.0 kV; nebulizer gas (N2) flow 3 L min-1; desolvation line temperature 526 °C; drying gas (N2) flow 10 L min-1; heating gas (synthetic air) flow 10 L min-1; and collision induced dissociation gas pressure (Ar) 270 kPa. The analyses were performed in multiple reaction monitoring (MRM) mode. MRM conditions used are presented in Table 1, being the entrance potential (EP), collision energy (CE) and collision cell exit potential (CCEP) optimized through the software LabSolutions (version 5.96, Shimadzu, Kyoto, Japan). Data were acquired and analyzed using the same software.

Table 1
Mass spectrometer parameters and retention times of fentanyl, its analogues and internal standard for the analysis in postmortem blood by LC-MS/MS

Sample preparation

This study was realized in accordance with the ethical standards of the University of Campinas committee (Comitê de Ética em Pesquisa da UNICAMP-CEP; CAAE 87316318.0.0000.5404) and Superintendence of the Technical-Scientific of Sao Paulo State Police (No. 766/2015/ATS/SPTC-SSP).

For sample preparation, 250 μL of postmortem blood were transferred to a polypropylene tube (2 mL), followed by 25 μL of internal standard (cocaine-d3 at 200 ng mL-1) and 1000 μL of iced-cold acetonitrile. The tube was capped, vortexed for 5 min and centrifuged at 14,000 rpm for 10 min. Then, 600 μL of the organic phase were transferred to a vial and 2 μL were injected into the LC-MS/MS.

Validation of the method

Blank postmortem blood for preparation of fortified matrix samples used during the validation was collected in blood collection tubes containing sodium fluoride and ethylenediaminetetraacetic tripotassium salt. The validation of the method was carried out in accordance with American National Standards Institute (ANSI), American Academy of Forensic Sciences (AAFS) Standards Board (ASB) Standard 036, Standard Practices for Method Validation in Forensic Toxicology2323 Approved American National Standard (ANSI)/Academy Standards Board (ASB); Standard Practices for Method Validation in Forensic Toxicology; ANSI/ASB: Colorado Springs, USA, 2019. [Link] accessed in December 2023
Link...
and the Standard for Identification Criteria in Forensic Toxicology.2424 Approved American National Standard (ANSI); Academy Standards Board (ASB); Standard for Identification Criteria in Forensic Toxicology; ANSI/ASB: Colorado Springs, USA, 2019. [Link] accessed in December 2023
Link...

Identification criteria were symmetrical peak eluting within ± 2% of average calibrator retention time, signal-to-noise ratio of 3 and ion ratio of the quantifying and qualifier MRM between ±20 to ±50% according to ANSI/ASB.2424 Approved American National Standard (ANSI); Academy Standards Board (ASB); Standard for Identification Criteria in Forensic Toxicology; ANSI/ASB: Colorado Springs, USA, 2019. [Link] accessed in December 2023
Link...
The lower limit of quantitation (LLOQ) was determined as the lowest concentration fulfilling the identification criteria, a signal-to-noise ratio of at least 10 and quantifying within 20% of each target concentration. Linearity was assessed with six-point calibration curves (1, 5, 10, 30, 50 and 100 ng mL-1) over 5 days and calibrators must quantify within ±20% relative standard deviation (RSD) of each target concentration. For the construction of the calibration curve, six weighting factors were analyzed (1/x, 1/x2, 1/x0.5, 1/y, 1/y2, 1/y0.5), being chosen the one with the lowest sum of residual regression errors (ΣRE%). A high correlation coefficient (r) value (r ≥ 0.99) and inaccuracy better than ±15% for all calibrators were used as criterion of adequate linearity.

Blank matrix samples were analyzed immediately after a fortified blood extract at the highest calibrator concentration to evaluate carryover. Negative postmortem blood samples fortified with forty-six drugs of abuse and pharmaceuticals at 200 ng mL-1 were analyzed to evaluate possible exogenous interferences. Analyzes of 10 different postmortem blood samples were performed for possible endogenous interferences.

Intraday (n = 3) and interday (n = 15) imprecision and bias were evaluated over 5 days and in triplicate, for low, medium and high QC concentrations. Imprecision was calculated through one-way analysis of variance (ANOVA) for each QC to evaluate the occurrence of significant variability (p < 0.05), values less than 20% were acceptable. Bias were calculated as the mean of the difference between the concentration expected for each QC and the value estimated for each observation and expressed as a percentage. Values in the range of 80-120% were considered acceptable.

Matrix effect and extraction yield were evaluated fortifying matrix samples at low and high QC concentrations. For matrix effect, two groups of six replicates were compared, using the equation: (a/b) × 100, being “a” the absolute area of the peak obtained from postmortem blood samples fortified before the extraction and “b”, those obtained from fortified ultrapure water. For extraction yield, the same equation was used, being “a” the results obtained from postmortem blood samples fortified before the extraction and “b”, those obtained from samples fortified after the extraction. Samples were extracted according to the method previously described and results were expressed as percentages.

Processed sample (autosampler) stability was evaluated at low and high QC samples in triplicate. After extraction and analysis, samples were stored on the autosampler at 10 °C and re-inject after 24 h. Peak areas obtained were compared with those from the analysis of a freshly extracted calibration curve.

Results and Discussion

Method validation

According to the ANSI/ASB guideline,2323 Approved American National Standard (ANSI)/Academy Standards Board (ASB); Standard Practices for Method Validation in Forensic Toxicology; ANSI/ASB: Colorado Springs, USA, 2019. [Link] accessed in December 2023
Link...
the LLOQ could be determined by using a decision point concentration, i.e., defining the LLOQ as the value of an administratively defined decision point, even though a lower LLOQ is analytically achievable. The therapeutic range for fentanyl is 0.3-1.2 ng mL-1.2525 Schulz, M.; Schmoldt, A.; Andresen-Streichert, H.; Iwersen-Bergmann, S.; Crit. Care 2020, 24, 195. [Crossref]
Crossref...
,2626 Dempsey, S. K.; Gray, T. R.; Kelly, A. T.; Stout, P.; Lee, D.; J. Anal. Toxicol. 2022, 46, 817. [Crossref]
Crossref...
Previously studies2626 Dempsey, S. K.; Gray, T. R.; Kelly, A. T.; Stout, P.; Lee, D.; J. Anal. Toxicol. 2022, 46, 817. [Crossref]
Crossref...
,2727 Walsh, E.; Forni, A.; Pardi, J.; Cooper, G.; J. Anal. Toxicol. 2021, 45, 835. [Crossref]
Crossref...
,2828 Finkelstein, M. J.; Chronister, C. W.; Stanley, C.; Ogilvie, L. M.; Goldberger, B. A.; J. Anal. Toxicol. 2019, 43, 392. [Crossref]
Crossref...
,2929 Fagiola, M.; Hahn, T.; Avella, J.; Acad. Forensic. Pathol. 2019, 9, 191. [Crossref]
Crossref...
,3030 Danaceau, J. P.; Wood, M.; Ehlers, M.; Rosano, T. G.; Clin. Mass Spectrom. 2020, 18, 38. [Crossref]
Crossref...
,3131 Busardò, F. P.; Carlier, J.; Giorgetti, R.; Tagliabracci, A.; Pacifici, R.; Gottardi, M.; Pichini, S.; Front. Chem. 2019, 7, 184. [Crossref]
Crossref...
,3232 Bastos, F. I.; Krawczyk, N.; Lancet Regional Health - Americas 2023, 23, 100507. [Crossref]
Crossref...
have shown that in postmortem cases involving fentanyl and its analogues, most of these analytes were above 1 ng mL-1. This method was focused on detecting fentanyl and analogues acute intoxications, situations were the concentrations used to be far from the therapeutic levels. Thus, the LLOQ of 1 ng mL-1 fits for method purpose and the MRM chromatograms of all analytes at this concentration are shown in Figure 1.

Figure 1
MRM chromatograms for fortified postmortem blood samples containing fentanyl and 7 analogues at LLOQ (1.0 ng mL-1).

The developed method was able to analyze fentanyl and 7 analogues with LLOQ of 1.0 ng mL-1. A linear curve from 1 to 100 ng mL-1 was evaluated and showed adequate performance using a 1/x weight linear regression, presenting a satisfactory linearity (r > 0.99). The errors of all calibrants were also evaluated, with inaccuracy always better than ±15%. No carryover or exogenous interference were observed, demonstrating the specificity of the method.

For evaluation of the imprecision, the ANOVA test was applied; the highest values found were 14.5% (intraday imprecision) and 19.7% (interday imprecision), both for the LLOQ of carfentanil (1 ng mL-1), being all the values accepted according to ANSI/ASB guideline. The bias was greater than 11.3, 10.7 and 8.0% for the LLOQ of furanyl fentanyl, low QC of acetyl norfentanil and LLOQ of thiofentanyl, respectively. Table 2 shows the results of imprecision and bias.

Table 2
Validation results for intraday and interday imprecision for fentanyl and its analogues in postmortem blood by LC-MS/MS

The extraction yield was higher than 58% (fentanyl, at high quality control concentration), and matrix effect was greater than 11.1% (acetyl fentanyl, at high quality control concentration). The results of imprecision, bias, matrix effect and extraction yield for each analyte are described in Table 3.

Table 3
Validation results for bias, matrix effect and extraction yield for fentanyl and its analogues in postmortem blood by LC-MS/MS

Analysis of authentic forensic toxicology cases

This method was applied in the Forensic Toxicology Laboratory of the São Paulo State Police for four months (n = 1,359 blood samples), with fentanyl being the most common opioid found in postmortem blood samples. Fentanyl was detected in 79 samples (45.4% of positive identifications among opioids), in concentrations between 1.0-18.7 ng mL-1. Figure 2 shows a positive sample for fentanyl.

Figure 2
MRM chromatograms obtained from an authentic postmortem blood sample containing fentanyl.

Only 1 case of acetyl norfentanyl was identified (11.8 ng mL-1), and no authentic sample was above the therapeutic concentration. Fentanyl is used as anesthetic in hospital surgeries, and most of the samples are also positive for midazolam, a common combination used for sedations and rapid sequence intubation. Since we observed only concentrations within the therapeutic range, we believe that we cannot classify the 79 positive samples as abuse of this substance. Despite the few cases of blotter papers containing fentanyl and the report of cocaine mixed with carfentanil in Argentina,3333 Molina, F. R.; Drug Used to Anesthetize Elephants Found in Adulterated Cocaine that Killed 24 in Argentina; El País: Buenos Aires, 2022. [Link] accessed in December 2023
Link...
,3434 Barbosa, L. M.; Santos, J. M.; de Morais, D. R.; Nimtz, A. V.; Eberlin, M. N.; de Oliveira, M. F.; Costa, J. L.; Drug Test. Anal. 2019, 11, 178. [Crossref]
Crossref...
the most consumed drugs in South America are cannabis, followed by cocaine, while opioids and opiates occupy fifth and sixth place, respectively, in prevalence of consumption.3535 United Nations Office on Drugs and Crime (UNODC); World Drug Report 2020; UNODC: Vienna, Austria, 2020. [Crossref] accessed in December 2023
Crossref...

Our work evaluated the profile of opioid consumption in postmortem cases of the São Paulo State since there is a lack of epidemiological data about consumption, addiction or fatal intoxications by these NPS. Besides, Bastos and Krawczyk3232 Bastos, F. I.; Krawczyk, N.; Lancet Regional Health - Americas 2023, 23, 100507. [Crossref]
Crossref...
recently published a comment addressing the growing use of fentanyl in present-day Brazil, expressing concern, but suggesting that a crisis similar to that in the US can still be prevented.3232 Bastos, F. I.; Krawczyk, N.; Lancet Regional Health - Americas 2023, 23, 100507. [Crossref]
Crossref...
With this method, the Forensic Toxicology Laboratory of the São Paulo State Police, which is responsible for the toxicological analysis of all 645 cities that are part of the State, is previously capable of detecting and quantifying these substances. Other methods were described for the analysis of fentanyl and its metabolites in biological samples, but using higher volumes of sample or needed more steps, including dryness of extraction solvent or solid-phase extraction (SPE).44 Rodda, L. N.; Pilgrim, J. L.; Di Rago, M.; Crump, K.; Gerostamoulos, D.; Drummer, O. H.; J. Anal. Toxicol. 2017, 41, 318. [Crossref]
Crossref...
,1818 Sofalvi, S.; Schueler, H. E.; Lavins, E. S.; Kaspar, C. K.; Brooker, I. T.; Mazzola, C. D.; Dolinak, D.; Gilson, T. P.; Perch, S.; J. Anal. Toxicol. 2017, 41, 473. [Crossref]
Crossref...
,1919 Shanks, K. G.; Behonick, G. S.; J. Anal. Toxicol. 2017, 41, 466. [Crossref]
Crossref...
,2020 Seither, J.; Reidy, L.; J. Anal. Toxicol. 2017, 41, 493. [Crossref]
Crossref...
Both steps increase the time spent on sample preparation and could be laborious, besides increasing the costs of the analysis. Moreover, compared to other studies, our method quantifies more fentanyl analogues.1818 Sofalvi, S.; Schueler, H. E.; Lavins, E. S.; Kaspar, C. K.; Brooker, I. T.; Mazzola, C. D.; Dolinak, D.; Gilson, T. P.; Perch, S.; J. Anal. Toxicol. 2017, 41, 473. [Crossref]
Crossref...
,1919 Shanks, K. G.; Behonick, G. S.; J. Anal. Toxicol. 2017, 41, 466. [Crossref]
Crossref...

Conclusions

A sensitive method was developed to quantify fentanyl and 7 of its analogues in postmortem blood samples by LC-MS/MS. The efficiency of the method was demonstrated through analysis of samples from forensic toxicology cases, being applied for 4 months in the routine of the Forensic Toxicology Laboratory, Institute of Legal Medicine of the São Paulo State Police, showing that fentanyl was the opioid mostly found.

Acknowledgments

The authors thank the Forensic Toxicology Laboratory, Institute of Legal Medicine of São Paulo State Police who supported the research. This work was financed by Fundação de Amparo à Pesquisa do Estado de São Paulo-FAPESP (process No. 2018/00432-1 and 2020/10809-5), Conselho Nacional de Desenvolvimento Científico e Tecnológico-CNPq (process No. 315640/2021-9) and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-CAPES (process No. 88882.435302/2019-01).

References

  • 1
    United Nations Office on Drugs and Crime (UNODC); World Drug Report 2015; UNODC: Vienna, Austria, 2015. [Link] accessed in December 2023
    » Link
  • 2
    United Nations Office on Drugs and Crime (UNODC), https://www.unodc.org/LSS/Page/NPS, accessed in December 2023.
    » https://www.unodc.org/LSS/Page/NPS,
  • 3
    Wu, F.; Slawson, M. H.; Johnson-Davis, K. L.; J. Anal. Toxicol. 2017, 41, 289. [Crossref]
    » Crossref
  • 4
    Rodda, L. N.; Pilgrim, J. L.; Di Rago, M.; Crump, K.; Gerostamoulos, D.; Drummer, O. H.; J. Anal. Toxicol. 2017, 41, 318. [Crossref]
    » Crossref
  • 5
    Ruzycki, S.; Yarema, M.; Dunham, M.; Sadrzadeh, H.; Tremblay, A.; J. Med. Toxicol. 2016, 12, 185. [Crossref]
    » Crossref
  • 6
    Yamanaka, T.; Sadikot, R. T.; Respirology 2013, 18, 255. [Crossref]
    » Crossref
  • 7
    Solé, D.; Spindola, M. A. C.; Aun, M. V. ; Azi, L. A.; Bernd, L. A. G.; Bianchi, D.; Capelo, A. V. ; Cumino, D.; Lacerda, A. E.; Lima, L. C.; Morato, E.; Nunes, R. R.; Rubini, N. P. M.; Silva, J.; Tardelli, M. A.; Watanabe, A. S.; Curi, E. F.; Sano, F.; Arquivos Asma, Alergia Imunol. 2020, 4, 35. [Crossref]
    » Crossref
  • 8
    Dewachter, P.; Lefebvre, D.; Kalaboka, S.; Bloch-Morot, E.; Acta Anaesthesiol. Scand. 2009, 53, 1092. [Crossref]
    » Crossref
  • 9
    Bakovic, M.; Nestic, M.; Mayer, D.; Int. J. Legal Med. 2015, 129, 1247. [Crossref]
    » Crossref
  • 10
    Swanson, D. M.; Hair, L. S.; Rivers, S. R. S.; Smyth, B. C.; Brogan, S. C.; Ventoso, A. D.; Vaccaro, S. L.; Pearson, J. M.; J. Anal. Toxicol. 2017, 41, 498. [Crossref]
    » Crossref
  • 11
    Ruan, X.; Chiravuri, S.; Kaye, A. D.; J. Anal. Toxicol. 2016, 41, 163. [Crossref]
    » Crossref
  • 12
    Ruan, X.; Chiravuri, S.; Kaye, A. D.; Forensic Sci., Med., Pathol. 2016, 12, 363. [Crossref]
    » Crossref
  • 13
    Poklis, J.; Poklis, A.; Wolf, C.; Hathaway, C.; Arbefeville, E.; Chrostowski, L.; Devers, K.; Hair, L.; Mainland, M.; Merves, M.; Pearson, J.; J. Anal. Toxicol. 2016, 40, 703. [Crossref]
    » Crossref
  • 14
    McIntyre, I. M.; Trochta, A.; Gary, R. D.; Wright, J.; Mena, O.; J. Anal. Toxicol. 2016, 40, 162. [Crossref]
    » Crossref
  • 15
    Fort, C.; Curtis, B.; Nichols, C.; Niblo, C.; J. Anal. Toxicol. 2016, 40, 754. [Crossref]
    » Crossref
  • 16
    Cunningham, S. M.; Haikal, N. A.; Kraner, J. C.; J. Forensic. Sci. 2016, 61, 276. [Crossref]
    » Crossref
  • 17
    United Nations Office on Drugs and Crime (UNODC); Global Smart Update: Fentanyl and its Analogues-50 Years on; UNODC: Vienna, Austria, 2017. [Link] accessed in December 2023
    » Link
  • 18
    Sofalvi, S.; Schueler, H. E.; Lavins, E. S.; Kaspar, C. K.; Brooker, I. T.; Mazzola, C. D.; Dolinak, D.; Gilson, T. P.; Perch, S.; J. Anal. Toxicol. 2017, 41, 473. [Crossref]
    » Crossref
  • 19
    Shanks, K. G.; Behonick, G. S.; J. Anal. Toxicol. 2017, 41, 466. [Crossref]
    » Crossref
  • 20
    Seither, J.; Reidy, L.; J. Anal. Toxicol. 2017, 41, 493. [Crossref]
    » Crossref
  • 21
    Drug Enforcement Administration (DEA); National Drug Threat Assessment (NDTA); DEA: USA, 2020. [Link] accessed in December 2023
    » Link
  • 22
    National Forensic Laboratory Information System (NFLIS); NFLIS-Drug 2019 Annual Report; U.S. Drug Enforcement: Springfield, United States of America, 2020. [Link] acessed in January 2024
    » Link
  • 23
    Approved American National Standard (ANSI)/Academy Standards Board (ASB); Standard Practices for Method Validation in Forensic Toxicology; ANSI/ASB: Colorado Springs, USA, 2019. [Link] accessed in December 2023
    » Link
  • 24
    Approved American National Standard (ANSI); Academy Standards Board (ASB); Standard for Identification Criteria in Forensic Toxicology; ANSI/ASB: Colorado Springs, USA, 2019. [Link] accessed in December 2023
    » Link
  • 25
    Schulz, M.; Schmoldt, A.; Andresen-Streichert, H.; Iwersen-Bergmann, S.; Crit. Care 2020, 24, 195. [Crossref]
    » Crossref
  • 26
    Dempsey, S. K.; Gray, T. R.; Kelly, A. T.; Stout, P.; Lee, D.; J. Anal. Toxicol. 2022, 46, 817. [Crossref]
    » Crossref
  • 27
    Walsh, E.; Forni, A.; Pardi, J.; Cooper, G.; J. Anal. Toxicol. 2021, 45, 835. [Crossref]
    » Crossref
  • 28
    Finkelstein, M. J.; Chronister, C. W.; Stanley, C.; Ogilvie, L. M.; Goldberger, B. A.; J. Anal. Toxicol. 2019, 43, 392. [Crossref]
    » Crossref
  • 29
    Fagiola, M.; Hahn, T.; Avella, J.; Acad. Forensic. Pathol. 2019, 9, 191. [Crossref]
    » Crossref
  • 30
    Danaceau, J. P.; Wood, M.; Ehlers, M.; Rosano, T. G.; Clin. Mass Spectrom. 2020, 18, 38. [Crossref]
    » Crossref
  • 31
    Busardò, F. P.; Carlier, J.; Giorgetti, R.; Tagliabracci, A.; Pacifici, R.; Gottardi, M.; Pichini, S.; Front. Chem. 2019, 7, 184. [Crossref]
    » Crossref
  • 32
    Bastos, F. I.; Krawczyk, N.; Lancet Regional Health - Americas 2023, 23, 100507. [Crossref]
    » Crossref
  • 33
    Molina, F. R.; Drug Used to Anesthetize Elephants Found in Adulterated Cocaine that Killed 24 in Argentina; El País: Buenos Aires, 2022. [Link] accessed in December 2023
    » Link
  • 34
    Barbosa, L. M.; Santos, J. M.; de Morais, D. R.; Nimtz, A. V.; Eberlin, M. N.; de Oliveira, M. F.; Costa, J. L.; Drug Test. Anal. 2019, 11, 178. [Crossref]
    » Crossref
  • 35
    United Nations Office on Drugs and Crime (UNODC); World Drug Report 2020; UNODC: Vienna, Austria, 2020. [Crossref] accessed in December 2023
    » Crossref

Edited by

Editor handled this article: Andrea R. Chaves (Associate)

Publication Dates

  • Publication in this collection
    12 Feb 2024
  • Date of issue
    2024

History

  • Received
    15 Aug 2023
  • Accepted
    19 Jan 2024
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br